Load Frequency Control of a Hydrothermal Hybrid Power System Using Evolutionary Optimization Algorithm

被引:0
|
作者
Lenka C. [1 ]
Ray P. [1 ]
Panda S.K. [1 ]
机构
[1] Department of Electrical Engineering, Veer Surendra Sai University of Technology, Odisha, Burla, Sambalpur
关键词
FOPID control; Fuzzy logic control; Hydro-thermal power system; Load frequency control; PID control; Teaching learning-based optimization technique;
D O I
10.1007/s40031-024-01021-2
中图分类号
学科分类号
摘要
In a networked distributed power system, even unexpected changes in load can result in significant tie-line frequency and power swings. To prevent this, load frequency management (LFM) is used to keep the frequency and energy output necessary to control tie line power variations between various places, which is the main objective of this work. An essential aspect of LFM is automatic generation control, which governs speed control, so LFM's purpose is fulfilled. In this work, a linked power system is considered, with each location having a thermal and a hydroelectric plant with reheat. Governor Dead Band (GDB) has been applied to each plant to provide a more realistic approach to the system. The proposed controller is the fuzzy PID, fractional-order PID (FOPID) and proportional–integral–derivative (PID). However, it is noticed that the conventional use of PID controller, and FOPID fails to operate correctly, leading to high instability in the power network. Then, FPID with triangular membership is considered, which performed better than PID and FOPID. Here, two robust heuristic algorithms are taken, giving the controller the best gains via teaching learning-based optimization (TLBO) and Differential evolution (DE) with Integral absolute Time-Multiplied Error (IATE) as the primary objective function. Further, performance evaluation of TLBO and DE optimized PID, FOPID and FPID controllers is done. The simulation findings show that, compared to DE-optimized PID and FOPID controllers, DE optimized Fuzzy PID controlling device lessens the frequency shift of the control regions and strengthens the line power. Also, DE optimized controllers give a better output as compared to TLBO tuned ones. MATLAB/SIMULINK has been used to carry out modelling and simulations. © The Institution of Engineers (India) 2024.
引用
收藏
页码:959 / 970
页数:11
相关论文
共 50 条
  • [41] Load frequency control of interconnected hydrothermal power system based on FOPI + FOPD controller
    Mingyong Cui
    Yue Zhao
    Peng Cao
    Yinggan Tang
    Yao Lu
    International Journal of Dynamics and Control, 2024, 12 : 1073 - 1085
  • [42] PSO-scaled fuzzy logic to load frequency control in hydrothermal power system
    V. Jeyalakshmi
    P. Subburaj
    Soft Computing, 2016, 20 : 2577 - 2594
  • [43] DECENTRALIZED SUBOPTIMAL LOAD-FREQUENCY CONTROL OF A HYDROTHERMAL POWER-SYSTEM USING THE STATE VARIABLE MODEL
    MALIK, OP
    HOPE, GS
    TRIPATHY, SC
    MITAL, N
    ELECTRIC POWER SYSTEMS RESEARCH, 1985, 8 (03) : 237 - 247
  • [44] A hybrid DE-PS algorithm for load frequency control under deregulated power system with UPFC and RFB
    Sahu, Rabindra Kumar
    Gorripotu, Tulasichandra Sekhar
    Panda, Sidhartha
    AIN SHAMS ENGINEERING JOURNAL, 2015, 6 (03) : 893 - 911
  • [45] Load Frequency Control of a Multi-Area Power System by Optimum Designing of Frequency-Based PID Controller Using Seeker Optimization Algorithm
    Parvaneh, Hesam
    Dizgah, Shahriar Moradinejad
    Sedighizadeh, Mostafa
    Ardeshir, Soheib Takht
    2016 6TH CONFERENCE ON THERMAL POWER PLANTS (CTPP), 2016, : 52 - 57
  • [46] Fuzzy Logic-Based Load Frequency Control in an Island Hybrid Power System Model Using Artificial Bee Colony Optimization
    Kumar, Neelamsetti Kirn
    Gopi, Rahul Sanmugam
    Kuppusamy, Ramya
    Nikolovski, Srete
    Teekaraman, Yuvaraja
    Vairavasundaram, Indragandhi
    Venkateswarulu, Siripireddy
    ENERGIES, 2022, 15 (06)
  • [47] Whale optimization algorithm applied to load frequency control of a mixed power system considering nonlinearities and PLL dynamics
    Guha, Dipayan
    Roy, Provas Kumar
    Banerjee, Subrata
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2020, 11 (03): : 699 - 728
  • [48] Whale optimization algorithm applied to load frequency control of a mixed power system considering nonlinearities and PLL dynamics
    Dipayan Guha
    Provas Kumar Roy
    Subrata Banerjee
    Energy Systems, 2020, 11 : 699 - 728
  • [49] Adaptive Load Frequency Control Based on Dynamic Jaya Optimization Algorithm of Power System with Renewable Energy Integration
    Ali, Mohamed Issam A.Elrefaei
    Diab, Ahmed A. Zaki
    Hassan, Ahmed A.
    2019 21st International Middle East Power Systems Conference, MEPCON 2019 - Proceedings, 2019, : 202 - 206
  • [50] Control Strategy for Industrial Load Participation in Power System Frequency Regulation Based on Particle Swarm Optimization Algorithm
    Song, Jing-Yue
    Yu, Ming-Hui
    Fan, Hao-Hui
    Zhang, Chuan-Ke
    Shangguan, Xing-Chen
    2024 14TH ASIAN CONTROL CONFERENCE, ASCC 2024, 2024, : 1480 - 1485