Thermochemical material; Potassium carbonate; Salt hydrate; Thermochemical energy storage; Micro-X-ray computed tomography; Packed bed reactor; HEAT-STORAGE; ENERGY-STORAGE;
D O I
10.1007/s10921-024-01092-7
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Thermochemical storage using salt hydrates presents a promising energy storage method. Ensuring the long-term effectiveness of the system is critical, demanding both chemical and mechanical stability of material for repetitive cycling. Challenges arise from agglomeration and volume variations during discharging and charging, impacting the cyclability of thermochemical materials (TCM). For practical usage, the material is often used in a packed bed containing millimetre-sized grains. A micro-level analysis of changes in a packed bed system, along with a deeper understanding involving quantifying bed characteristics, is crucial. In this study, micro X-ray computed tomography (XCT) is used to compare changes in the packed bed before and after cycling the material. Findings indicate a significant decrease in pore size distribution in the bed after 10 cycles and a decrease in porosity from 41.34 to 19.91% accompanied by an increase in grain size, reducing void space. A comparison of effective thermal conductivity between the uncycled and cycled reactor indicates an increase after cycling. Additionally, the effective thermal conductivity is lower in the axial direction compared to the radial. XCT data from uncycled and cycled experiments are further used to observe percolation paths inside the bed. Furthermore, at a system scale fluid flow profile comparison is presented for uncycled and cycled packed beds. It has been observed that the permeability decreased and the pressure drop increased from 0.31 to 4.88 Pa after cycling.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Characterization of Prebake Anodes by Micro X-ray Computed Tomography
    Rorvik, Stein
    Lossius, Lorentz Petter
    LIGHT METALS 2017, 2017, : 1237 - 1245
  • [22] Tracking the infiltration of molten salt into graphite using time-lapse X-ray micro-computed tomography
    Zhang, Xun
    Theodosiou, Alex
    Bodel, William
    Quayle, Phil
    Fox, Ciara
    Hankinson, Chris
    Morgans, Chris
    Jones, Abbie N.
    MATERIALIA, 2024, 33
  • [23] ANALYSIS OF INNER STRUCTURE CHANGES OF CONCRETES EXPOSED TO HIGH TEMPERATURES USING MICRO X-RAY COMPUTED TOMOGRAPHY
    Sitek, Libor
    Bodnarova, Lenka
    Soucek, Kamil
    Stas, Lubomir
    Gurkova, Lucie
    ACTA GEODYNAMICA ET GEOMATERIALIA, 2015, 12 (01): : 79 - 89
  • [24] X-Ray micro-Computed Tomography and micro X-ray Fluorescence mapping of synthetic emerald by using a laboratory polycapillary optics X-ray tube layout
    Liedl, A.
    Polese, C.
    Hampai, D.
    Della Ventura, G.
    Dabagov, S. B.
    Marcelli, A.
    Bellatreccia, F.
    Cavallo, A.
    X-RAY SPECTROMETRY, 2015, 44 (04) : 201 - 203
  • [25] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [26] Micro X-Ray computed tomography imaging and ultrasonic velocity measurements in tetrahydrofuran-hydrate-bearing sediments
    Schindler, Mandy
    Batzle, Michael L.
    Prasad, Manika
    GEOPHYSICAL PROSPECTING, 2017, 65 (04) : 1025 - 1036
  • [27] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [28] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [29] X-ray computed tomography
    不详
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [30] X-ray computed tomography
    Nature Reviews Methods Primers, 1