Research purposes: The 27.5 kV bus voltage of electrified railway traction substation is an important parameter of the power supply capacity and protection setting. Progressive failure of 27. 5 kV bus voltage transformer often occurs in actual operation. But the existing bus voltage monitoring measures can not detect the progressive fault in time, which eventually leads to the protection action outlet tripping and the power loss of the whole bus, expanding the scope of the accident. It is necessary to study the characteristics and monitoring methods of 27. 5 kV bus voltage in traction substation.Research conclusions: (1) The 27.5 kV bus voltage of traction substation is mainly affected by the capacity of traction transformer and system short-circuit capacity, of which the system short-circuit capacity has a greater impact.(2) The 27. 5 kV bus voltage of high-speed railway traction substation has the characteristics of high no-load voltage and limited fluctuation range. The fluctuation range is basically between 24 ~ 29 kV from maximum load to no-load.(3) The monitoring method of 27. 5 kV bus voltage value low alarm function and bus voltage transformer voltage difference high alarm function is proposed for electrified railway. (4) The research results in this paper can provide reference for identifying the bus voltage anomaly as soon as possible and ensuring the normal operation of traction substation. © 2023 Editorial Department of Journal of Railway Engineering Society. All rights reserved.
引用
收藏
页码:79 / 83
相关论文
共 38 条
  • [21] Research of noise characteristics for 10-kV medium-voltage power lines
    Tao, Zheng
    Yang Xiaoxian
    Zhang Baohui
    Jian, Chen
    Zhi, Yao
    Tian Zhihong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 142 - 150
  • [22] Research on on-line monitoring methods of high voltage parameter in electric vehicles
    Chunming, Zhao
    Qing, Li
    World Electric Vehicle Journal, 2010, 4 (02): : 232 - 237
  • [23] Research on On-line Monitoring Methods of High Voltage Parameter in Electric Vehicles
    Zhao Chun-ming
    Zhang Song-bo
    Li Qing
    Li Peng
    25TH WORLD BATTERY, HYBRID AND FUEL CELL ELECTRIC VEHICLE SYMPOSIUM AND EXHIBITION PROCEEDINGS, VOLS 1 & 2, 2010, : 259 - 264
  • [24] Research on Discharge Characteristics and Altitude Correction of Typical Air-gap in 500kV High-Altitude Substation
    Yao Xiuyuan
    Ding Yujian
    Zhang Yadi
    Sun Wenxiu
    Wang Bingqiang
    Jiang Dexi
    Liu Yusheng
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3269 - 3274
  • [25] Research on Short-term Prediction Method of Substation Bus-bar's Voltage Trend Based on Multidimensional Time Series Data Mining
    Xiao, Fei
    Leng, Xiwu
    Ye, Kang
    Hu, Youlin
    Li, Xiongli
    Zhu, Licheng
    2018 2ND INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING (ICPEE 2018), 2018, 192
  • [26] Research on visualization monitoring technology of vulnerable high-voltage electrical equipment in substation based on BP artificial neural network
    Cheng L.
    Hu X.
    Applied Mathematics and Nonlinear Sciences, 2024, 9 (01)
  • [27] Research on Velocity Control Methods for Driving Motor of 126kV High Voltage Circuit Breaker
    Teng Yun
    Wang Yifei
    Lin Xin
    2013 2ND INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2013,
  • [28] Research on Condition Monitoring Method of Mechanical Characteristics of Low-Voltage Circuit Breaker
    Hu B.
    Li K.
    Niu F.
    Zhao C.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (13): : 3317 - 3330
  • [29] Research on a Multi layer Distributed On-line Monitoring System of 10kV High Voltage Switchgear
    Zhang Siyu
    Mei Jun
    Zheng Jianyong
    Mei Fei
    2013 FOURTH INTERNATIONAL CONFERENCE ON DIGITAL MANUFACTURING AND AUTOMATION (ICDMA), 2013, : 1025 - 1028
  • [30] Influence of polluting methods on icing and flashover characteristics of 220 kV composite insulators under ac working voltage
    State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing
    400044, China
    不详
    400015, China
    Zhongguo Dianji Gongcheng Xuebao, 18 (4817-4824):