Closed-loop Laser Volume Ablation with Adaptive Scan Paths

被引:0
|
作者
Matthias Buser [1 ]
Tobias Menold [1 ]
Andreas Michalowski [1 ]
机构
[1] University of Stuttgart,Institut für Strahlwerkzeuge
关键词
Laser milling; Closed-loop control; Scan path; Optimization; OCT;
D O I
10.1007/s40516-024-00264-7
中图分类号
学科分类号
摘要
This research focuses on closed-loop control in laser volume ablation, also known as laser milling. Such process control enables precise ablation results on workpieces with much wider tolerances regarding the initial surface geometry, internal structure, or its response to the incident laser beam, compared to conventional open-loop processing. However, state of the art closed-loop ablation systems incorporate the process control at the cost of increased processing time. The two main causes are the alternating between processing and measuring, and the use of static scan paths that do not adapt continuously to the evolving geometry of the workpiece during processing. This study addresses this issue by proposing a parallelized work flow of processing, measuring the surface topography and adaptive path planning, eliminating interruptions and achieving faster processing through continuously optimized scan paths. The realized machining system achieved a mean reduction in processing time of 29%, 36%, and 52% on three different test geometries compared to the state of the art.
引用
收藏
页码:649 / 660
页数:11
相关论文
共 50 条
  • [41] An Adaptive Closed-Loop Approach for Timely Data Services
    Fernando, Dinuni
    Kang, Kyong-Don
    Zhou, Yan
    2017 IEEE 23RD INTERNATIONAL CONFERENCE ON EMBEDDED AND REAL-TIME COMPUTING SYSTEMS AND APPLICATIONS (RTCSA), 2017,
  • [42] Adaptive closed-loop paradigm of electrophysiology for neuron models
    Yang, Ming
    Wang, Jiang
    Li, Shanshan
    Wang, Kuanchuan
    Yue, Wei
    Liu, Chen
    NEURAL NETWORKS, 2023, 165 : 406 - 419
  • [43] Closed-loop adaptive optical system with a liquid mirror
    Vdovin, Gleb
    OPTICS LETTERS, 2009, 34 (04) : 524 - 526
  • [45] CLOSED-LOOP TEMPERATURE-CONTROLLED RADIOFREQUENCY CATHETER ABLATION
    GILLETTE, PC
    CASE, CL
    CALKINS, HG
    CIRCULATION, 1993, 88 (04) : 165 - 165
  • [46] Laser phase spectroscopy in closed-loop multilevel schemes
    Arimondo, Ennio
    APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (12):
  • [47] Wavefront Aberration Correction for Laser Propagating Over Water with a Closed-loop Adaptive Optical System
    Song, Hong
    Huang, Haocai
    Yang, Ping
    Chen, Lei
    Lan, Ruihong
    Chen, Jiawang
    Qu, Fengzhong
    Xie, Yingjun
    Leng, Jianxing
    Chen, Ying
    OCEANS, 2012 - YEOSU, 2012,
  • [48] Laser phase spectroscopy in closed-loop multilevel schemes
    Ennio Arimondo
    Applied Physics B, 2016, 122
  • [49] Closed-Loop Temperature Control Based on Fiber Bragg Grating Sensors for Laser Ablation of Hepatic Tissue
    Korganbayev, Sanzhar
    Orrico, Annalisa
    Bianchi, Leonardo
    De Landro, Martina
    Wolf, Alexey
    Dostovalov, Alexander
    Saccomandi, Paola
    SENSORS, 2020, 20 (22) : 1 - 16
  • [50] Closed-loop focus control systems for laser welding
    Haran, FM
    Hand, DP
    Peters, C
    Jones, JDC
    ICALEO'96 - PROCEEDINGS OF THE LASERS AND ELECTRO-OPTICS FOR AUTOMOTIVE MANUFACTURING CONFERENCE, 1996, 82 : 154 - 163