Closed-loop Laser Volume Ablation with Adaptive Scan Paths

被引:0
|
作者
Matthias Buser [1 ]
Tobias Menold [1 ]
Andreas Michalowski [1 ]
机构
[1] University of Stuttgart,Institut für Strahlwerkzeuge
关键词
Laser milling; Closed-loop control; Scan path; Optimization; OCT;
D O I
10.1007/s40516-024-00264-7
中图分类号
学科分类号
摘要
This research focuses on closed-loop control in laser volume ablation, also known as laser milling. Such process control enables precise ablation results on workpieces with much wider tolerances regarding the initial surface geometry, internal structure, or its response to the incident laser beam, compared to conventional open-loop processing. However, state of the art closed-loop ablation systems incorporate the process control at the cost of increased processing time. The two main causes are the alternating between processing and measuring, and the use of static scan paths that do not adapt continuously to the evolving geometry of the workpiece during processing. This study addresses this issue by proposing a parallelized work flow of processing, measuring the surface topography and adaptive path planning, eliminating interruptions and achieving faster processing through continuously optimized scan paths. The realized machining system achieved a mean reduction in processing time of 29%, 36%, and 52% on three different test geometries compared to the state of the art.
引用
收藏
页码:649 / 660
页数:11
相关论文
共 50 条
  • [1] Closed-loop adaptive optical system for laser beam control
    Kudryashov, A
    Rukosuev, A
    Alexandrov, A
    Zavalova, V
    Samarkin, V
    LASER RESONATORS IV, 2001, 4270 : 37 - 44
  • [2] RATE ADAPTIVE PACEMAKER USELYING INTRACARDIAC VOLUME FOR CLOSED-LOOP CONTROL
    BOHEIM, G
    SCHALDACH, M
    BIOMEDIZINISCHE TECHNIK, 1988, 33 (05): : 100 - 105
  • [3] On closed-loop adaptive noise cancellation
    Kushner, HJ
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1998, 43 (08) : 1103 - 1107
  • [4] On closed-loop adaptive noise cancellation
    Brown Univ, Providence, United States
    IEEE Trans Autom Control, 8 (1103-1107):
  • [5] ADAPTIVE IDENTIFICATION IN CLOSED-LOOP SYSTEMS
    AKSENOV, VM
    PASHCHENKO, FF
    AUTOMATION AND REMOTE CONTROL, 1980, 41 (10) : 1388 - 1396
  • [6] Adaptive autofocusing: a closed-loop perspective
    Zhang, Y
    Wen, CY
    Soh, YC
    Fong, AM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (04) : 625 - 635
  • [7] Adaptive Closed-Loop Bladder Neuromodulation
    Peh, Wendy Y. X.
    Raczkowska, Marlena N.
    Teh, Yuni
    Alam, Monzurul
    Thakor, Nitish V.
    Yen, Shih-Cheng
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [8] High-precision laser ablation using OCT closed-loop control
    Holder, Daniel
    Buser, Matthias
    Leis, Artur
    Boley, Steffen
    Weber, Rudolf
    Graf, Thomas
    LASER APPLICATIONS IN MICROELECTRONIC AND OPTOELECTRONIC MANUFACTURING (LAMOM) XXV, 2020, 11267
  • [9] Closed-loop design of a semiconductor laser
    Moloney, J. V.
    Hader, J.
    Fan, L.
    Fallahi, M.
    Koch, S. W.
    Stolz, W.
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES XI, 2007, 6475
  • [10] Closed-loop design of a semiconductor laser
    Hader, Jorg
    Moloney, Jerome V.
    Fallahi, Mahmoud
    Fan, Li
    Koch, Stephan W.
    OPTICS LETTERS, 2006, 31 (22) : 3300 - 3302