Impression Disinfection and Its Effect on Dimensional Accuracy and Surface Detail in the Times of COVID-19: An In Vitro Study

被引:0
|
作者
Sabharwal, Niharika [1 ]
Arora, Aman [2 ]
Upadhyaya, Viram [2 ]
Sehgal, Monika M. [2 ]
Nayak, Karvika [1 ]
Katyal, Setu [3 ]
Dahiya, Manisha [2 ]
Pratap, Chandrama [2 ]
Sharma, Radhika [2 ]
机构
[1] Inst Technol & Sci ITS, Dent Coll, Prosthodont, Ghaziabad, India
[2] JN Kapoor Dayanand Anglo Ved DAV Dent Coll, Prosthodont, Yamunanagar, India
[3] Inst Technol & Sci ITS, Dent Coll, Endodont, Ghaziabad, India
关键词
surface detail reproduction; dimensional accuracy; herbal disinfectant; virucidal; ultraviolet radiation; ozonated water; peracetic acid; impression disinfection; WATER;
D O I
10.7759/cureus.55931
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The disinfection of impressions is crucial to eliminate the viral and other microbial loads to prevent the cross contamination of diseases. The aim of this study was to compare the effect of different virucidal disinfecting methods on the dimensional accuracy and surface detail reproduction (SDR) of impression materials. Methods A total of 160 samples were fabricated with different impression materials using zinc oxide eugenol (Group 1), alginate (Group 2), polyether (Group 3), and addition silicone (Group 4) impression materials, each containing 40 samples (n=40). These groups were further divided into Subgroups A, B, C, and D (n=10) based on the disinfecting method used. Disinfection was carried out using 0.2% peracetic acid (A), a natural polymer of glucosamine (B), ultraviolet (UV) radiation (C), and ozonated water (D). The disinfected impressions were poured in type IV gypsum, and the obtained casts were checked for dimensional accuracy and surface detail reproduction (SDR). For dimensional accuracy, a one-way analysis of variance (ANOVA) test and, for surface detail reproduction, the chi-square test were used to compare the different subgroups of each impression material separately. Results Zinc oxide eugenol samples showed the lowest mean dimensional change when disinfected with 0.2% peracetic acid (1A=154.1 mu m), and alginate showed the lowest mean dimensional change when disinfected using ozonated water (2D=134.9 mu m). On the other hand, the lowest mean dimensional change observed in polyether and addition silicone samples was those which were disinfected using UV radiation (3C=100.9 mu m and 4C=113.5 mu m). Surface detail was reproduced adequately in most of the samples. Conclusion A 0.2% peracetic acid could be used to disinfect zinc oxide eugenol impressions, ozonated water for alginate impressions, and UV radiation for polyether and addition silicone impressions.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Accuracy of Impression Material During COVID-19 after Sterilization-In vitro Study
    Alhaddad, Abdulrahman Jafar
    [J]. JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (50B) : 241 - 246
  • [2] Disinfection procedures: Their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material
    Rentzia, A.
    Coleman, D. C.
    O'Donnell, M. J.
    Dowling, A. H.
    O'Sullivan, M.
    [J]. JOURNAL OF DENTISTRY, 2011, 39 (02) : 133 - 140
  • [3] Vinyl polysiloxane impression material dimensional accuracy and surface detail reproduction.
    Al-Ruthea, M
    O'Connell, B
    Claffey, N
    Houston, F
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B297 - B297
  • [4] Dimensional Accuracy and Surface Detail Reproduction of Hydrophilic Polyvinylsiloxane Impression Material Tested under Dry and Moist Salivary Conditions: An In vitro Study
    Nayyar, Abhishek Singh
    [J]. BIOMEDICAL AND BIOTECHNOLOGY RESEARCH JOURNAL, 2021, 5 (01): : 59 - 63
  • [5] ELASTOMERIC IMPRESSION MATERIALS - DIMENSIONAL STABILITY AND SURFACE DETAIL SHARPNESS FOLLOWING TREATMENT WITH DISINFECTION SOLUTIONS
    BERGMAN, M
    OLSSON, S
    BERGMAN, B
    [J]. SWEDISH DENTAL JOURNAL, 1980, 4 (04) : 161 - 167
  • [6] Effect of chemical disinfection on surface detail reproduction and dimensional stability of a new vinyl polyether silicone elastomeric impression material
    Khatri, Monika
    Mantri, Sneha S.
    Deogade, Suryakant C.
    Bhasin, Abhilasha
    Mantri, Shivkumar
    Khatri, Neetu
    Jain, Priyanka
    Chauhan, Deepak
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2020, 11 (01) : 10 - 14
  • [7] Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts
    Taylor, RL
    Wright, PS
    Maryan, C
    [J]. DENTAL MATERIALS, 2002, 18 (02) : 103 - 110
  • [8] Evaluation of the effect of chemical disinfection and ultraviolet disinfection on the dimensional stability of polyether impression material: an in-vitro study
    Joshi, Snehal
    Madhav, V. N. V.
    Saini, Ravinder S.
    Gurumurthy, Vishwanath
    Alshadidi, Abdulkhaliq Ali F.
    Aldosari, Lujain Ibrahim N.
    Okshah, Abdulmajeed
    Mosaddad, Seyed Ali
    Heboyan, Artak
    [J]. BMC ORAL HEALTH, 2024, 24 (01)
  • [9] Covid-19: effect of disinfection on corrosion of surfaces
    Bonin, L.
    Vitry, V.
    Olivier, M-G
    Bertolucci-Coelho, L.
    [J]. CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2020, 55 (08) : 693 - 695
  • [10] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    [J]. JOURNAL OF DENTISTRY, 2022, 126