Final report "Key comparison CCM.FF-K1.2015 - water flow: 30 m3/h ... 200 m3/h"

被引:3
|
作者
Furuichi N. [1 ]
Arias R. [2 ]
Yang C.-T. [3 ]
Chun S. [4 ]
Meng T. [5 ]
Shinder I. [6 ]
Frahm E. [7 ]
Büker O. [8 ]
Mills C. [9 ]
Akselli B. [10 ]
Smits F.M. [11 ]
机构
[1] NMIJ/AIST - National Institute of Advanced Industrial Science and Technology, National Metrology Institute of Japan, Fluid Flow Division, Aist Tsukuba Central 3, 1-1-1 Umezono, Tsukuba
[2] Cenam - Centro Nacional de Metrología, km 4.5 carretera a los Cués, El Marqués, Qro., México
[3] Itri - Industrial Technology Research Institute, Center for Measurement Standards, Bldg. 16, No. 321, Sec. 2, Kuang-Fu Rd., Chinese Taipei, Hsinchu
[4] Kriss - Korea Research Institute of Standards and Science, Thermometry and Fluid Flow Metrology Group, Division of Physical Metrology, 205A-dong 101-ho, Gajeong-ro 267, Yuseong-gu, Daejeon
[5] Nim - National Institute of Metrology, Division of Thermometry and Material Evaluation, No. 18 Bei San Huan Dong Lu, Chaoyang District, Beijing
[6] Nist - National Institute of Standards and Technology, 100 Bureau Dr, Gaithersburg, 20899, MD
[7] Ptb - Physikalisch-Technische Bundesanstalt, Department 1.5 Liquid Flow, Bundesallee 100, Braunschweig
[8] Rise - Research Institutes of Sweden, Measurement Science and Technology, Brinellgatan 4, Borås
[9] Tüv Süd National Engineering Laboratory, Scottish Enterprise Technology Park, East Kilbride, Glasgow
[10] Tubitak Ume - National Metrology Institute, Fluid Mechanics Laboratory, Baris Mah. Dr. Zeki Acar cad. No: 1, Gebze/Kocaeli
[11] Vsl - National Metrology Institute, Thijsseweg 11, Delft
关键词
Calibration - Flow measurement - Flow of water - Flowmeters - Hydraulics - Turbines - Uncertainty analysis;
D O I
10.1088/0026-1394/59/1A/07013
中图分类号
学科分类号
摘要
Main text The objective of the Key Comparison CCM.FF-K1.2015 for water flow measurement was to support and prove the Calibration and Measurement Capabilities (CMC) of the participating NMIs of Japan (AIST), Mexico (CENAM), Chinese Taipei (ITRI), Korea (KRISS), P.R. China (NIM), Germany (PTB), USA (NIST), Sweden (RISE), UK (NEL), Turkey (TUBITAK UME) and Netherlands (VSL). The comparison was organized as a round robin, started in December 2015 at PTB and finished in April 2018, also at PTB. As pilot laboratory, the national metrology institute of Germany (PTB) organised the comparison. A combined setup of a turbine meter and Coriolis meter was used as a transfer standard (TS), which was provided by the pilot laboratory. The nominal calibration conditions of the KC were defined within the flow range between 30 m3/h and 200 m3/h, 20 °C fluid temperature and 3 bar line pressure. A special focus of the comparison was to estimate the uncertainties of the transfer standard (u TS). Both transfer meters were subjected to extensive characterization measurements at pilot laboratory, with the following investigated parameters: fluid temperature, line pressure, repeatability, flow stability, meter sensitivity to varying inflow conditions and hysteresis effects. For turbine meter, all labs passed the E N criteria of ≤ 1.20. The calibrations of the turbine meter were strongly affected by the presence of the large values for u TS with > 0.12 % k =1) which were mainly caused by the meter sensitivity to disturbed inflow conditions. This effect led to inconclusive calibration results for all laboratories. The evaluation criteria u comp/u base exceeded the critical value of 2.00. Finally, the turbine meter was not suitable for a confirmation of all submitted CMC values. For Coriolis meter, all labs passed the E N criteria of ≤ 1.20. In contrast to turbine meter, the evaluation criteria u comp/u base exceeded the critical value of 2.00 for one laboratory, only. The maximum uncertainty u TS of Coriolis meter was estimated with 0.022 % (k =1). In summary, the comparison was successfully finished for a confirmation of the submitted CMC values, related to mass calibrations. For volume related CMCs this comparison was not suitable. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2022 BIPM & IOP Publishing Ltd.
引用
收藏
相关论文
共 50 条
  • [41] Final report on CIPM key comparison of 1 kg standards in stainless steel (CCM.M-K1)
    Aupetit, C.
    Becerra, L. O.
    Bignell, N.
    Bich, W.
    Chapman, G. D.
    Chung, J. W.
    Coarasa, J.
    Davidson, S.
    Davis, R.
    Domostroeva, N. G.
    Fen, K. M. K.
    Glaser, M.
    Lee, W. G.
    Lecollinet, M.
    Li, Q.
    Ooiwa, A.
    Spurny, R.
    Torino, A.
    Verbeek, J. C. G. A.
    Jabbour, Z. J.
    METROLOGIA, 2004, 41
  • [42] Final report on CCM.M-K4: Key comparison of 1 kg stainless steel mass standards
    Becerra, Luis Omar
    Borys, Michael
    Chung, Jin Wan
    Davidson, Stuart
    Fuchs, Peter
    Jacques, Claude
    Jian, Wang
    Kubarych, Zeina J.
    Kumar, Anil
    Malengo, Andrea
    Fenn, Kitty
    Medina, Nieves
    Meury, Paul-Andre
    Mizushima, Shigeki
    Picard, Alain
    Steyn, Ronel
    Zelenka, Zoltan
    METROLOGIA, 2014, 51
  • [43] Comparisons of national standards in the field of gas flow rate and volume, gas flow rates from 20 to 6500 m3/h
    Mingaleev, A. V.
    Yakovlev, A. B.
    Mickan, B.
    Bardonov, A. I.
    Serediuk, D.
    Stankevicius, A.
    Busuladzic, I.
    METROLOGIA, 2020, 57 (1A)
  • [44] Final report on the torque key comparison CCM.T-K1.1: Measurand torque: 0 N m, 500 N m, 1000 N m
    Roeske, Dirk
    METROLOGIA, 2010, 47
  • [46] 10万m3/h焦炉煤气净化系统特点分析
    杜万古
    冶金动力, 1999, (03) : 5 - 8
  • [47] MAGNETIC-PROPERTIES OF M3(ASO4)2.8H2O (M=CO, NI)
    MELERO, JJ
    BURRIEL, R
    LEZAMA, L
    GARCIATOJAL, J
    ROJO, T
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (02) : 981 - 984
  • [48] Electrochemical performance of M3(BTC)2•12H2O (M=Co, Ni, and Zn) for Supercapacitors
    Liao, Chenmin
    Zhao, Jiachang
    Tang, Bohejin
    Tang, Aomin
    Sun, Yanhong
    Xu, Jingli
    JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2012, 15 (02) : 79 - 82
  • [49] Curvelinear belt conveyor of 8100 m3/h capacity-design, construction & operation experience
    Majkowski, Andrzej
    Murzyński, Zdzislaw
    Prace Naukowe Instytutu Gornictwa Politechniki Wroclawskiej, 1998, (82): : 238 - 245
  • [50] Effluent reuse at Barranco Seco (Spain):: a 1,000 m3/h case study
    Broens, L
    Liebrand, N
    Futselaar, H
    Torrent, JCD