Rapid detection of West Nile and Dengue viruses from mosquito saliva by loop-mediated isothermal amplification and displaced probes

被引:0
|
作者
Kim, Dongmin [1 ]
DeBriere, Terry J. [2 ]
Eastmond, Bradley H. [1 ]
Alomar, Abdullah A. [1 ]
Yaren, Ozlem [3 ,4 ]
McCarter, Jacquelyn [3 ,4 ]
Bradley, Kevin M. [4 ]
Benner, Steven A. [3 ,4 ]
Alto, Barry W. [1 ]
Burkett-Cadena, Nathan D. [1 ]
机构
[1] Univ Florida, Florida Med Entomol Lab, Vero Beach, FL 32962 USA
[2] TrakitNow Inc, Columbia, SC USA
[3] Firebird Biomol Sci LLC, Alachua, FL 32615 USA
[4] Fdn Appl Mol Evolut, Alachua, FL 32615 USA
来源
PLOS ONE | 2024年 / 19卷 / 02期
关键词
EQUINE ENCEPHALITIS-VIRUS; ARBOVIRUS SURVEILLANCE; VECTOR COMPETENCE; AEDES-AEGYPTI; DIPTERA; LAMP; CULICIDAE; SUSCEPTIBILITY; IDENTIFICATION; TEMPERATURE;
D O I
10.1371/journal.pone.0298805
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Arthropod-borne viruses are major causes of human and animal disease, especially in endemic low- and middle-income countries. Mosquito-borne pathogen surveillance is essential for risk assessment and vector control responses. Sentinel chicken serosurveillance (antibody testing) and mosquito pool screening (by RT-qPCR or virus isolation) are currently used to monitor arbovirus transmission, however substantial time lags of seroconversion and/or laborious mosquito identification and RNA extraction steps sacrifice their early warning value. As a consequence, timely vector control responses are compromised. Here, we report on development of a rapid arbovirus detection system whereby adding sucrose to reagents of loop-mediated isothermal amplification with displaced probes (DP-LAMP) elicits infectious mosquitoes to feed directly upon the reagent mix and expectorate viruses into the reagents during feeding. We demonstrate that RNA from pathogenic arboviruses (West Nile and Dengue viruses) transmitted in the infectious mosquito saliva was detectable rapidly (within 45 minutes) without RNA extraction. Sucrose stabilized viral RNA at field temperatures for at least 48 hours, important for transition of this system to practical use. After thermal treatment, the DP-LAMP could be reliably visualized by a simple optical image sensor to distinguish between positive and negative samples based on fluorescence intensity. Field application of this technology could fundamentally change conventional arbovirus surveillance methods by eliminating laborious RNA extraction steps, permitting arbovirus monitoring from additional sites, and substantially reducing time needed to detect circulating pathogens.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Rapid and Sensitive Detection of Listeria monocytogenes by Loop-Mediated Isothermal Amplification
    Meng-Jun Tang
    Sheng Zhou
    Xiao-Yan Zhang
    Jun-Hua Pu
    Qing-Lian Ge
    Xiu-Jun Tang
    Yu-Shi Gao
    Current Microbiology, 2011, 63
  • [42] Rapid and Sensitive Detection of Lophophora williamsii by Loop-Mediated Isothermal Amplification
    Sasaki, Yohei
    Fujimoto, Tsuguto
    Aragane, Masako
    Yasuda, Ichiro
    Nagumo, Seiji
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2009, 32 (05) : 887 - 891
  • [43] Establishment of loop-mediated isothermal amplification for rapid detection of Pseudomonas aeruginosa
    Li, Chao
    Shi, Yaoqiang
    Yang, Guangying
    Xia, Xue-Shan
    Mao, Xiaoqin
    Fang, Yue
    Zhang, A-Mei
    Song, Yuzhu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 17 (01) : 131 - 136
  • [44] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Zhao, Jiangtao
    Feng, Ruo
    VIRUS GENES, 2019, 55 (01) : 43 - 50
  • [45] Loop-mediated isothermal amplification for rapid detection of Bacillus anthracis spores
    Yan-Mei Qiao
    Yong-Chao Guo
    Xian-En Zhang
    Ya-Feng Zhou
    Zhi-Ping Zhang
    Hong-Ping Wei
    Rui-Fu Yang
    Dian-Bing Wang
    Biotechnology Letters, 2007, 29 : 1939 - 1946
  • [46] Loop-mediated Isothermal Amplification Method for Rapid Detection of Shigella dysenteriae
    Zhong, Qingping
    Wang, Li
    Wang, Bin
    Chen, Hongyuan
    MEDICAL MATERIALS AND ENGINEERING, 2012, 140 : 369 - +
  • [47] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Jiangtao Zhao
    Ruo Feng
    Virus Genes, 2019, 55 : 43 - 50
  • [48] The Rapid Detection of Salmonella from Food Samples By Loop-Mediated Isothermal Amplification (LAMP)
    Ueda, Shigeko
    Kuwabara, Yoshihiro
    BIOCONTROL SCIENCE, 2009, 14 (02) : 73 - 76
  • [49] Loop-mediated isothermal amplification assay for detection of four immunosuppressive viruses in chicken
    Song, HyeSoon
    Bae, YouChan
    Park, SeokChan
    Kwon, HyukMan
    Lee, HeeSoo
    Joh, SeongJoon
    JOURNAL OF VIROLOGICAL METHODS, 2018, 256 : 6 - 11
  • [50] LABORATORY AND FIELD EVALUATIONS OF A COMMERCIALLY AVAILABLE REAL-TIME LOOP-MEDIATED ISOTHERMAL AMPLIFICATION ASSAY FOR THE DETECTION OF WEST NILE VIRUS IN MOSQUITO POOLS
    Burkhalter, Kristen L.
    O'Keefe, Michael
    Holbert-Watson, Zachary
    Green, Theodore
    Savage, Harry M.
    Markowski, Daniel M.
    JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION, 2021, 37 (04) : 256 - 262