Energy and Exergy Analysis of an Ejector Expansion Transcritical Carbon Dioxide Air Conditioning System

被引:0
|
作者
Jose, Jobel [1 ,2 ]
Kanna, Parthasarathy Rajesh [2 ]
Arumugam, Senthil Kumar [3 ]
机构
[1] Vellore Inst Technol, Sch Mech Engn, Vellore, India
[2] Vellore Inst Technol, CO2 Res & Green Technol Ctr, Vellore, Tamil Nadu, India
[3] VIT Bhopal Univ, Sch Mech Engn, Bhopal, India
关键词
CO2 REFRIGERATION CYCLE; HEAT-PUMP; 2-PHASE EJECTOR; PERFORMANCE; PRESSURE; EXPANDER; DESIGN; EFFICIENCIES; VALIDATION;
D O I
10.1080/01457632.2024.2347174
中图分类号
O414.1 [热力学];
学科分类号
摘要
A carbon dioxide based transcritical air conditioning system integrated with an ejector is thermodynamically modeled and the system is simulated for different ambient conditions. Throughout the analysis, the isentropic efficiency of motive nozzle, suction nozzle and diffuser is assumed as 85% while the mixing takes place at constant pressure. A step-by-step iterative procedure is adopted to obtain the pressure lift and entrainment ratio. The present thermodynamic model is validated with the experimental results available in the open literature. Results were then compared to a conventional transcritical carbon dioxide system working between the same operating conditions. Results show a significant improvement of about 21% and more in system performance compared to a conventional system working under the same operating conditions. To justify the application of an ejector as an expansion work recovery device and to identify the component level exergy destruction rate, a comprehensive exergy analysis is implemented and the results show 20% reduction in total exergy destruction rate of the system, with an ejector.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [41] Comparative Exergy Analysis and Environmental Impact of a Dairy Plant Integrated with a Transcritical Heat Pump System: A Feasibility of Throttle Valve, Expander, and an Ejector as Expansion Devices
    Biswajit Gorai
    Satyabrata Sahoo
    Arabian Journal for Science and Engineering, 2023, 48 : 3503 - 3521
  • [42] Exergy Analysis of a Heating Ventilation and Air Conditioning (HVAC) System
    Prakash, K.
    Islam, F. R.
    Mamun, K. A.
    Sharma, A.
    Sen, A.
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2018, : 378 - 383
  • [43] An experimental study of an ejector-boosted transcritical R744 refrigeration system including an exergy analysis
    Elbarghthi, Anas F. A.
    Hafner, Armin
    Banasiak, Krzysztof
    Dvorak, Vaclav
    ENERGY CONVERSION AND MANAGEMENT, 2021, 238
  • [44] Analysis of a solar-assisted ejector cooling system for air conditioning
    Varga, Szabolcs
    Oliveira, Armando C.
    Diaconu, Bogdan
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2009, 4 (01) : 2 - 8
  • [45] Energy and exergy analysis of a ceiling-type air conditioning system operating with different refrigerants
    Ozbek, A.
    JOURNAL OF ENGINEERING RESEARCH, 2016, 4 (03): : 144 - 162
  • [46] Energy and exergy analysis of a tri-generation water-cooled air conditioning system
    Mohammadi, S. M. Hojjat
    Ameri, Mehran
    ENERGY AND BUILDINGS, 2013, 67 : 453 - 462
  • [47] EXERGY ANALYSIS OF AN AIR CONDITIONING PROCESS
    Duranovic, Matej
    Rauch, Martina
    Galovic, Antun
    Zivic, Marija
    TRANSACTIONS OF FAMENA, 2021, 45 : 1 - 12
  • [48] Advanced exergy and exergoeconomic analysis of a novel liquid carbon dioxide energy storage system
    Liu, Zhan
    Liu, Zihui
    Yang, Xuqing
    Zhai, Hongyan
    Yang, Xiaohu
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [49] Energy and exergy performance of the IHX position in ejector expansion refrigeration systems
    Rodriguez-Munoz, J. L.
    Perez-Garcia, V.
    Belman-Flores, J. M.
    Ituna-Yudonago, J. F.
    Gallegos-Munoz, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 93 : 122 - 131
  • [50] Energy analysis of a solar-assisted ejector cycle air conditioning system with low temperature thermal energy storage
    Diaconu, Bogdan M.
    RENEWABLE ENERGY, 2012, 37 (01) : 266 - 276