3D fascicular reconstruction of median and ulnar nerve: initial experience and comparison between high-resolution ultrasound and MR microscopy

被引:11
|
作者
Pusnik, Luka [1 ]
Lechner, Lisa [2 ]
Sersa, Igor [1 ,3 ]
Cvetko, Erika [1 ]
Haas, Philipp [2 ]
Jengojan, Suren Armeni [2 ]
Snoj, Ziga [4 ,5 ]
机构
[1] Univ Ljubljana, Inst Anat, Fac Med, Ljubljana, Slovenia
[2] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Vienna, Austria
[3] Jozef Stefan Inst, Dept Condensed Matter Phys, Ljubljana, Slovenia
[4] Univ Ljubljana, Fac Med, Dept Radiol, Ljubljana, Slovenia
[5] Univ Med Ctr Ljubljana, Inst Radiol, Ljubljana, Slovenia
关键词
Artificial intelligence; Imaging (three-dimensional); Magnetic resonance imaging; Peripheral nerves; Ultrasound; INTRAOPERATIVE ULTRASOUND; ULTRASONOGRAPHY; RELIABILITY; MANAGEMENT; SEVERITY; US;
D O I
10.1186/s41747-024-00495-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe complex anatomy of peripheral nerves has been traditionally investigated through histological microsections, with inherent limitations. We aimed to compare three-dimensional (3D) reconstructions of median and ulnar nerves acquired with tomographic high-resolution ultrasound (HRUS) and magnetic resonance microscopy (MRM) and assess their capacity to depict intraneural anatomy.MethodsThree fresh-frozen human upper extremity specimens were prepared for HRUS imaging by submersion in a water medium. The median and ulnar nerves were pierced with sutures to improve orientation during imaging. Peripheral nerve 3D HRUS scanning was performed on the mid-upper arm using a broadband linear probe (10-22 MHz) equipped with a tomographic 3D HRUS system. Following excision, nerves were cut into 16-mm segments and loaded into the MRM probe of a 9.4-T system (scanning time 27 h). Fascicle and nerve counting was performed to estimate the nerve volume, fascicle volume, fascicle count, and number of interfascicular connections. HRUS reconstructions employed artificial intelligence-based algorithms, while MRM reconstructions were generated using an open-source imaging software 3D slicer.ResultsCompared to MRM, 3D HRUS underestimated nerve volume by up to 22% and volume of all fascicles by up to 11%. Additionally, 3D HRUS depicted 6-60% fewer fascicles compared to MRM and visualized approximately half as many interfascicular connections.ConclusionMRM demonstrated a more detailed fascicular depiction compared to 3D HRUS, with a greater capacity for visualizing smaller fascicles. While 3D HRUS reconstructions can offer supplementary data in peripheral nerve assessment, their limitations in depicting interfascicular connections and small fascicles within clusters necessitate cautious interpretation.Clinical relevance statementAlthough 3D HRUS reconstructions can offer supplementary data in peripheral nerve assessment, even in intraoperative settings, their limitations in depicting interfascicular branches and small fascicles within clusters require cautious interpretation.Key Points3D HRUS was limited in visualizing nerve interfascicular connections.MRM demonstrated better nerve fascicle depiction than 3D HRUS.MRM depicted more nerve interfascicular connections than 3D HRUS.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] High-resolution 3D MR imaging of aging ciliary body and lens
    Strenk, SA
    Jacob, J
    Strenk, LM
    Alvarez, T
    Semmlow, JL
    DeMarco, JK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4567 - 4567
  • [32] Rapid Acquisition of 3D Images Using High-resolution Episcopic Microscopy
    Zhang, Haochuan
    Huang, JunGang
    Liu, Xin
    Zhu, Ping
    Li, Zhongrong
    Li, Xue
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (117):
  • [33] Simple high-resolution 3D microscopy by a dielectric microsphere: a proof of concept
    Abbasian, Vahid
    Darafsheh, Arash
    Moradi, Ali-reza
    OPTICS LETTERS, 2023, 48 (23) : 6216 - 6219
  • [34] Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta
    von Knobelsdorff-Brenkenhoff, Florian
    Gruettner, Henriette
    Trauzeddel, Ralf F.
    Greiser, Andreas
    Schulz-Menger, Jeanette
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (06) : 651 - 658
  • [35] Unsupervised 3D Reconstruction with Multi-Measure and High-Resolution Loss
    Zheng, Yijie
    Luo, Jianxin
    Chen, Weiwei
    Zhang, Yanyan
    Sun, Haixun
    Pan, Zhisong
    SENSORS, 2023, 23 (01)
  • [36] HIGH-RESOLUTION 3D RECONSTRUCTION FOR COMPLEX COLOR SCENES WITH STRUCTURED LIGHT
    Hu, Weidong
    Gong, Mingying
    Hong, Yanhui
    Sun, Lifeng
    Yang, Shiqiang
    2014 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO WORKSHOPS (ICMEW), 2014,
  • [37] 3D Reconstruction of Building Based on High-Resolution SAR and Optical Images
    Zhu Junjie
    Ding Chibiao
    You Hongjian
    Xie Minghong
    2006 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, 2006, : 3794 - 3797
  • [38] A review of 3D reconstruction from high-resolution urban satellite images
    Zhao, Li
    Wang, Haiyan
    Zhu, Yi
    Song, Mei
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2023, 44 (02) : 713 - 748
  • [39] 3D building reconstruction and validation using high-resolution stereo data
    Singla, Jai Gopal
    Trivedi, Sunanda
    CURRENT SCIENCE, 2022, 122 (08): : 900 - 906
  • [40] Native high-resolution 3D SSFP MR angiography for assessing the thoracic aorta
    Florian von Knobelsdorff
    Henriette Gruettner
    Ralf F Trauzeddel
    Andreas Greiser
    Jeanette Schulz-Menger
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)