3D fascicular reconstruction of median and ulnar nerve: initial experience and comparison between high-resolution ultrasound and MR microscopy

被引:11
|
作者
Pusnik, Luka [1 ]
Lechner, Lisa [2 ]
Sersa, Igor [1 ,3 ]
Cvetko, Erika [1 ]
Haas, Philipp [2 ]
Jengojan, Suren Armeni [2 ]
Snoj, Ziga [4 ,5 ]
机构
[1] Univ Ljubljana, Inst Anat, Fac Med, Ljubljana, Slovenia
[2] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Vienna, Austria
[3] Jozef Stefan Inst, Dept Condensed Matter Phys, Ljubljana, Slovenia
[4] Univ Ljubljana, Fac Med, Dept Radiol, Ljubljana, Slovenia
[5] Univ Med Ctr Ljubljana, Inst Radiol, Ljubljana, Slovenia
关键词
Artificial intelligence; Imaging (three-dimensional); Magnetic resonance imaging; Peripheral nerves; Ultrasound; INTRAOPERATIVE ULTRASOUND; ULTRASONOGRAPHY; RELIABILITY; MANAGEMENT; SEVERITY; US;
D O I
10.1186/s41747-024-00495-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe complex anatomy of peripheral nerves has been traditionally investigated through histological microsections, with inherent limitations. We aimed to compare three-dimensional (3D) reconstructions of median and ulnar nerves acquired with tomographic high-resolution ultrasound (HRUS) and magnetic resonance microscopy (MRM) and assess their capacity to depict intraneural anatomy.MethodsThree fresh-frozen human upper extremity specimens were prepared for HRUS imaging by submersion in a water medium. The median and ulnar nerves were pierced with sutures to improve orientation during imaging. Peripheral nerve 3D HRUS scanning was performed on the mid-upper arm using a broadband linear probe (10-22 MHz) equipped with a tomographic 3D HRUS system. Following excision, nerves were cut into 16-mm segments and loaded into the MRM probe of a 9.4-T system (scanning time 27 h). Fascicle and nerve counting was performed to estimate the nerve volume, fascicle volume, fascicle count, and number of interfascicular connections. HRUS reconstructions employed artificial intelligence-based algorithms, while MRM reconstructions were generated using an open-source imaging software 3D slicer.ResultsCompared to MRM, 3D HRUS underestimated nerve volume by up to 22% and volume of all fascicles by up to 11%. Additionally, 3D HRUS depicted 6-60% fewer fascicles compared to MRM and visualized approximately half as many interfascicular connections.ConclusionMRM demonstrated a more detailed fascicular depiction compared to 3D HRUS, with a greater capacity for visualizing smaller fascicles. While 3D HRUS reconstructions can offer supplementary data in peripheral nerve assessment, their limitations in depicting interfascicular connections and small fascicles within clusters necessitate cautious interpretation.Clinical relevance statementAlthough 3D HRUS reconstructions can offer supplementary data in peripheral nerve assessment, even in intraoperative settings, their limitations in depicting interfascicular branches and small fascicles within clusters require cautious interpretation.Key Points3D HRUS was limited in visualizing nerve interfascicular connections.MRM demonstrated better nerve fascicle depiction than 3D HRUS.MRM depicted more nerve interfascicular connections than 3D HRUS.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Median and ulnar nerve fascicle imaging using MR microscopy and high-resolution ultrasound
    Ziga, Snoj
    Igor, Sersa
    Ursa, Maticic
    Plut, Domen
    Erika, Cvetko
    Gregor, Omejec
    JOURNAL OF NEUROIMAGING, 2022, 32 (03) : 420 - 429
  • [2] Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist
    John K. Sutherland
    Taiki Nozaki
    Yasuhito Kaneko
    Hon J. Yu
    Gregory Rafijah
    David Hitt
    Hiroshi Yoshioka
    BMC Musculoskeletal Disorders, 17
  • [3] Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist
    Sutherland, John K.
    Nozaki, Taiki
    Kaneko, Yasuhito
    Yu, Hon J.
    Rafijah, Gregory
    Hitt, David
    Yoshioka, Hiroshi
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [4] High-Resolution 3D MR Imaging of the Trochlear Nerve
    Choi, B. S.
    Kim, J. H.
    Jung, C.
    Hwang, J. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) : 1076 - 1079
  • [5] Evaluation Of freehand high-resolution 3-dimensional ultrasound of the median nerve
    Pelz, Johann Otto
    Busch, Maria
    Weinreich, Anna
    Saur, Dorothee
    Weise, David
    MUSCLE & NERVE, 2017, 55 (02) : 206 - 212
  • [6] Local Readjustment for High-Resolution 3D Reconstruction
    Zhu, Siyu
    Fang, Tian
    Xiao, Jianxiong
    Quan, Long
    2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 3938 - 3945
  • [7] High-resolution ultrasound of the posterior femoral cutaneous nerve: visualization and initial experience with patients
    Stefan Meng
    Doris Lieba-Samal
    Lukas F. Reissig
    Gerlinde M. Gruber
    Peter C. Brugger
    Hannes Platzgummer
    Gerd Bodner
    Skeletal Radiology, 2015, 44 : 1421 - 1426
  • [8] High-resolution ultrasound of the posterior femoral cutaneous nerve: visualization and initial experience with patients
    Meng, Stefan
    Lieba-Samal, Doris
    Reissig, Lukas F.
    Gruber, Gerlinde M.
    Brugger, Peter C.
    Platzgummer, Hannes
    Bodner, Gerd
    SKELETAL RADIOLOGY, 2015, 44 (10) : 1421 - 1426
  • [9] High-resolution human brain 3D reconstruction with light-sheet fluorescence microscopy
    Costantini, Irene
    Scardigli, Marina
    Ramazzotti, Josephine
    Brady, Niamh
    Cheli, Franco
    Mazzamuto, Giacomo
    Castelli, Filippo
    Checcucci, Curzio
    Silvestri, Ludovico
    Frasconi, Paolo
    Pavone, Francesco Saverio
    NEURAL IMAGING AND SENSING 2023, 2023, 12365
  • [10] 3D high-resolution pure optical photoacoustic microscopy
    Xie, Zhixing
    Chen, Sung-Liang
    Ling, Tao
    Guo, L. Jay
    Carson, Paul L.
    Wang, Xueding
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223