Comparison of chest- and wrist-based actigraphy in pulmonary arterial hypertension

被引:4
|
作者
Lachant, Daniel [1 ]
Light, Allison [1 ]
Hannon, Kevin [2 ]
Abbas, Farrukh [1 ]
Lachant, Michael [1 ]
White, R. James [1 ]
机构
[1] Univ Rochester, Div Pulm & Crit Care Med, Med Ctr, 601 Elmwood Ave,Box 692, Rochester, NY 14620 USA
[2] Univ Rochester, Internal Med, Med Ctr, 601 Elmwood Ave, Rochester, NY 14620 USA
来源
基金
美国国家卫生研究院;
关键词
Activity tracker; Wearable; PAH; Steps; Activity time; PHYSICAL-ACTIVITY; ANKLE;
D O I
10.1093/ehjdh/ztab095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Activity trackers for clinical trials and remote monitoring are appealing as they provide objective data outside of the clinic setting. Algorithms determine physical activity intensity and count steps. Multiple studies show physical inactivity in pulmonary arterial hypertension (PAH). There are no studies comparing different activity trackers worn on different parts of the body in PAH. We had patients with PAH simultaneously wear two different accelerometers, compared measures between the two devices, and correlated the measures with standard clinical metrics in PAH. Methods and results This was a single-centre, prospective observational study. Daily physical activity and daily total steps were measured using Actigraph GT9X Link and MC10 Biostamp nPoint for 5-10 days. Actigraph was worn on the non-dominant hand and the MC10 Biostamp nPoint was worn on the chest and leg with disposable adhesives. Twenty-two participants wore both accelerometers >12 h/day for an average 7.8 days. The average activity time measured by Actigraph was significantly higher than that measured by MC10 (251 +/- 25 min vs. 113 +/- 18 min, P = 0.0001). Actigraph's algorithm reported more time in light activity than moderate (190 +/- 62 min vs. 60 +/- 56 min, P = 0.0001). REVEAL 2.0 scores correlated highly with activity time measured using either device. Invasively measured haemodynamics within 7 days did not correlate with activity time or daily steps. Conclusion Different activity trackers yield discordant results in PAH patients. Further studies are needed in determining the best device, optimal wear time, and different thresholds for activities in chronic diseases. [GRAPHICS] .
引用
下载
收藏
页码:90 / 97
页数:8
相关论文
共 50 条
  • [21] Pulmonary arterial hypertension: a comparison between children and adults
    Barst, R. J.
    Ertel, S. I.
    Beghetti, M.
    Ivy, D. D.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) : 665 - 677
  • [22] Mediators in Pulmonary Hypertension: A Comparison Between Pulmonary Arterial Hypertension and Diastolic Heart Failure-Induced Pulmonary Hypertension
    Mazurek, Jeremy A.
    Saeed, Wajeeha
    Sarswat, Nitasha
    Selim, Ahmed
    Velankar, Pradnya
    Zolty, Ronald
    CIRCULATION, 2010, 122 (21)
  • [23] Comparison of multichannel and single-channel wrist-based devices with polysomnography to measure sleep in children and adolescents
    Burkart, Sarah
    Beets, Michael W.
    Armstrong, Bridget
    Hunt, Ethan T.
    Dugger, Roddrick
    von Klinggraeff, Lauren
    Jones, Alexis
    Brown, David E.
    Weaver, R. Glenn
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (04): : 645 - 652
  • [24] Utility of Pulmonary Artery Diameter in Computed Tomography of Chest as a screening tool for Pulmonary Arterial Hypertension
    Sadoughi, A.
    Chandak, T. R.
    Kohn, N.
    Hutchinson, A. P.
    Shah, R.
    Talwar, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [25] Cardiovascular Parameters of Chest CT Scan in Estimating Pulmonary Arterial Pressure in Patients With Pulmonary Hypertension
    Li, Mengxi
    Wang, Shouyang
    Lin, Weiquan
    Li, Jinhui
    Zeng, Qingsi
    Wang, Jian
    CHEST, 2016, 149 (04) : 496A - 496A
  • [26] Cardiovascular parameters of chest CT scan in estimating pulmonary arterial pressure in patients with pulmonary hypertension
    Li, Mengxi
    Wang, Shouyang
    Lin, Weiquan
    Li, Jinhui
    Wang, Chunyang
    Chen, Huai
    Lu, Wenju
    Yang, Kai
    Wang, Jian
    Zeng, Qingsi
    CLINICAL RESPIRATORY JOURNAL, 2018, 12 (02): : 572 - 579
  • [27] Comparison of Clinical Features between Idiopathic Pulmonary Arterial Hypertension and Chronic Thromboembolic Pulmonary Hypertension
    Kim, Hyun Kuk
    Na, Joo Ock
    Ahn, Jong Joon
    Park, Yong Bum
    Lim, Jae Min
    Koh, Younsuck
    Kim, Woo Sung
    Kim, Dong Soon
    Kim, Won Dong
    Lee, Sang-Do
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2005, 59 (02) : 170 - 178
  • [28] Prostacyclin Levels in Pulmonary Hypertension: A Comparison Between Pulmonary Arterial Hypertension and Diastolic Heart Failure-Induced Pulmonary Hypertension
    Mazurek, Jeremy A.
    Salamon, Jason N.
    Saeed, Wajeeha
    Zolty, Ronald
    CIRCULATION, 2011, 124 (21)
  • [29] Relaxin levels in pulmonary hypertension: A comparison between pulmonary arterial hypertension and diastolic heart failure-induced pulmonary hypertension
    Mazurek, Jeremy A.
    Horne, Benjamin D.
    Kelesidis, Iosif
    Salmon, Jason N.
    Zolty, Ronald
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (03): : 371 - 374
  • [30] Artificial intelligence-based model for predicting pulmonary arterial hypertension on chest x-ray images
    Imai, Shun
    Sakao, Seiichiro
    Nagata, Jun
    Naito, Akira
    Sekine, Ayumi
    Sugiura, Toshihiko
    Shigeta, Ayako
    Nishiyama, Akira
    Yokota, Hajime
    Shimizu, Norihiro
    Sugawara, Takeshi
    Nomi, Toshiaki
    Honda, Seiwa
    Ogaki, Keisuke
    Tanabe, Nobuhiro
    Baba, Takayuki
    Suzuki, Takuji
    BMC PULMONARY MEDICINE, 2024, 24 (01)