Comparison between slow strain rate test and constant load test on notched specimens for HSLA steels HE susceptibility evaluation

被引:1
|
作者
Alvarenga, Rodrigo F. S. [1 ]
Bose Filho, Waldek W. [1 ]
Franco, Sinesio D. [1 ]
Ferreira, Daniel C. F. [2 ]
机构
[1] Univ Fed Uberlandia, 2121 Joao Naves De Avila Ave,Campus Santa Monica, BR-38400902 Uberlandia, MG, Brazil
[2] Ctr Pesquisas Leopoldo Americo Miguez Mello, Ctr Pesquisas Leopoldo Americo Miguez De Mello, 950 Horacio Macedo Ave, BR-21941915 Rio De Janeiro, RJ, Brazil
关键词
Hydrogen embrittlement; Cathodic protection; Slow strain rate test; Constant load test; Hydrostatic stress; HYDROGEN EMBRITTLEMENT SUSCEPTIBILITY; TRANSPORT; FRACTURE; DAMAGE;
D O I
10.1016/j.engfailanal.2024.108321
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The assessment of hydrogen embrittlement (HE) susceptibility in high-strength steels, intended for use in subsea components that are exposed to cathodic protection for corrosion control, is of great importance. Therefore, the present study investigates the behavior of AISI 4340 steel with hardness of 32, 36 and 40 HRC. The investigation involves employing slow strain rate test (nSSRT) and constant load test (CLT) on notched specimens with three different notch root radii. These tests were carried out under two different levels of cathodic protection (-1100 and -950 mV Ag|AgCl ) in a 3.5 % wt NaCl aqueous solution. The outcomes from the tests on notched specimens were compared with the hydrostatic stress profile obtained through finite element analysis (FEA). Additionally, the post -test fracture surfaces were analyzed using scanning electron microscopy (SEM). The test results revealed a higher hydrogen embrittlement index (HEI) with increasing material hardness and the applied cathodic potential. Moreover, a smaller notch radius was associated with a higher HEI. A clear correlation was observed between HEI and the extent of intergranular fracture in the test samples. Furthermore, the results from the nSSRT tests were correlated with the threshold stress ( sigma th ) obtained from CLT. It was evident that a relationship of sigma th = 90 % sigma nSSRT_min could be employed for a faster determination of this parameter.
引用
收藏
页数:17
相关论文
共 41 条
  • [41] Evaluation of the novel Helicobacter pylori ClariRes real-time PCR assay for detection and clarithromycin susceptibility testing of H-pylori in stool specimens and gastric biopsies;: Comparison with the stool antigen test drug resistance
    Puz, S.
    Kovach, Z.
    Hirschl, A. M.
    Hafner, M.
    Innerhofer, A.
    Rotter, M.
    Makristathis, A.
    HELICOBACTER, 2006, 11 (04) : 396 - 396