Heat transport characteristics of a flat-evaporator loop heat pipe for use in a thermal management system of electric vehicles

被引:3
|
作者
Nam, Bomi [1 ]
Joung, Wukchul [1 ,2 ]
机构
[1] Pukyong Natl Univ, Dept Intelligent Robot Engn, 45 Yongso Ro, Busan, 48513, South Korea
[2] Pukyong Natl Univ, Dept Mech Engn, 45 Yongso Ro, Busan, 48513, South Korea
基金
新加坡国家研究基金会;
关键词
Flat -evaporator loop heat pipe; Electric vehicle thermal management; Position; Heat sink temperature; Water-ethanol binary mixture; OPERATIONAL CHARACTERISTICS; WATER; PERFORMANCE; BINARY; MIXTURES; FLUID;
D O I
10.1016/j.ijheatmasstransfer.2024.125553
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, a flat-evaporator loop heat pipe (FELHP), with a 100 cm2 rectangular thermal interface and an overall length of approximately 2 m was devised for the thermal management of electric vehicles. A simple rectangular-cuboid evaporator was devised using a novel stepped-flat wick structure, and the heat transport characteristics were systematically investigated in terms of the heat load, relative height of the evaporator to the condenser (i.e., position), heat sink temperature, and working fluid. In particular, water-ethanol binary mixtures with different compositions were tested to find an optimum low-freezing-temperature working fluid for use in thermal management system of the electric vehicles driving outdoors. Over the tested heat load range, a significant position dependence of the operating temperature was observed with a thermal resistance change from 0.21 K/W +/- 0.02 K/W to 0.14 K/W +/- 0.01 K/W for a 0.4 m change in the position. In contrast, the operating temperature of the FELHP was insensitive to changes in the heat sink temperature. A binary mixture containing 20% water and 80% ethanol (by volume) resulted in comparable heat transport characteristics to those of pure water but had a much lower freezing temperature (e.g., a thermal resistance of 0.25 K/W +/- 0.03 K/W at 450 W and a freezing temperature of approximately -59 degrees C), demonstrating that this was an optimum composition of the water-ethanol mixture working fluid of the FELHP.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Operating characteristics of an anti-gravity loop heat pipe with a flat evaporator that has the capability of a loop thermosyphon
    Watanabe, Noriyuki
    Nguyen Phan
    Saito, Yuki
    Hayashi, Shota
    Katayama, Naoki
    Nagano, Hosei
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [42] Startup characteristics of an ammonia loop heat pipe with a rectangular evaporator
    Lizhan Bai
    Zehui Yang
    Xiaobin Shen
    Yuandong Guo
    Guiping Lin
    Dongsheng Wen
    Heat and Mass Transfer, 2022, 58 : 813 - 831
  • [43] Three-dimensional simulation on heat transfer in the flat evaporator of miniature loop heat pipe
    Zhang, Xianfeng
    Li, Xuanyou
    Wang, Shuangfeng
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 54 : 188 - 198
  • [44] Startup characteristics of an ammonia loop heat pipe with a rectangular evaporator
    Bai, Lizhan
    Yang, Zehui
    Shen, Xiaobin
    Guo, Yuandong
    Lin, Guiping
    Wen, Dongsheng
    HEAT AND MASS TRANSFER, 2022, 58 (05) : 813 - 831
  • [45] Heat and mass transfer in a flat disc-shaped evaporator of a miniature loop heat pipe
    Tu, Z. K.
    Liu, Z. C.
    Liu, C.
    Gai, D. X.
    Wan, Z. M.
    Liu, W.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2009, 223 (G6) : 609 - 618
  • [46] Multi-evaporator hybrid loop heat pipe for small spacecraft thermal management
    Bugby, David
    Wrenn, Kimberly
    Wolf, David
    Kroliczek, Edward
    Yun, James
    Krein, Stephen
    Mark, Daniel
    2005 IEEE Aerospace Conference, Vols 1-4, 2005, : 810 - 823
  • [47] Heat transport characterization on different orientations of a loop heat pipe with an additive manufactured evaporator
    Akizuki, Yuki
    Odagiri, Kimihide
    Sawada, Kenichiro
    Yoshizaki, Hiroshi
    Sairaiji, Masahiko
    Ogawa, Hiroyuki
    APPLIED THERMAL ENGINEERING, 2025, 264
  • [48] Experimental study on a dual-parallel-evaporator heat pump system for thermal management of electric vehicles
    Zhang, Guiying
    Qin, Fei
    Zou, Huiming
    Tian, Changqing
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 2390 - 2395
  • [49] Experimental investigation on temperature oscillation in a miniature loop heat pipe with flat evaporator
    Zhang, Xianfeng
    Huo, Jiepeng
    Wang, Shuangfeng
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 37 : 29 - 36
  • [50] Fabrication and testing of a miniature flat evaporator loop heat pipe with polydimethylsiloxane and molding
    Nguyen Phan
    Nagano, Hosei
    APPLIED THERMAL ENGINEERING, 2020, 175