Evaluation of performance deterioration of plywood sheathing wall subjected to repeated cyclic loading

被引:0
|
作者
Yamazaki Y. [1 ]
Suzuki K. [2 ]
Matsuda K. [3 ]
Sakata H. [2 ]
机构
[1] Dept. of Architecture, Meijo Univ.
基金
日本学术振兴会;
关键词
Equivalent damping ratio; Loading protocol; Performance deterioration; Post-earthquake functional use;
D O I
10.3130/AIJT.27.202
中图分类号
学科分类号
摘要
Seismic performance of timber shear walls is generally confirmed through experiment which is provided in the standard. However, the strength and deformation capacities are clearly related to the loading protocol, and such a fatigue behavior is not well-understood so far. In this paper, plywood sheathing wall having 12mm thickness of plywood is tested, and the fatigue behaviors coming up on force-deformation relation and equivalent damping ratio are evaluated. © 2021 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:202 / 206
页数:4
相关论文
共 50 条
  • [31] Experimental investigation of performance in L-shaped wall to wall corner connections of 3D Panels subjected to lateral cyclic loading
    Kabir, M. Z.
    Vasheghani-Farahani, R.
    STRUCTURAL ENGINEERING AND MECHANICS, 2009, 33 (05) : 649 - 652
  • [32] Analytical performance evaluation of modified inclined studs for steel plate concrete wall subjected to cyclic loads
    Lim, Jin-Sun
    Jeong, Young-Do
    Nam, Jin-Won
    Kim, Chun-Ho
    Yi, Seong-Tae
    COMPUTERS AND CONCRETE, 2016, 17 (02): : 227 - 240
  • [33] Fatigue performance of ordinary concrete subjected to stepwise discontinuous cyclic loading
    Jiang D.
    Liu W.
    Chen J.
    Pan X.
    Sun Z.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (04): : 631 - 637
  • [34] PERFORMANCE OF REDUCED BEAM SECTION IN CASTELLATED BEAM SUBJECTED TO CYCLIC LOADING
    Aswad, Nini Hasriyani
    Parung, Herman
    Irmawaty, Rita
    Amiruddin, A. Arwin
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (09) : 2872 - 2882
  • [35] Analysis of the performance of the concrete specimens subjected to cyclic loading and aggressive environment
    Goeringer, J.
    Foglar, M.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 269 - 276
  • [36] Performance of RC columns with debonded bars subjected to cyclic lateral loading
    Mitra, Damodaran Chitra
    Bindhu, Kochunaraya Rugmini
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (13): : 626 - 642
  • [37] Evaluation of the risk of sudden failure of a cohesive soil subjected to cyclic loading
    Martinez, Eliana
    Patino, Hernan
    Galindo, Ruben
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2017, 92 : 419 - 432
  • [38] Structural Performance of Disaster Relief Housing Units Subjected to Cyclic Loading
    Ha, Taehyu
    Kim, Dae-Jin
    Han, Choong Hee
    ADVANCES IN APPLIED MATERIALS AND ELECTRONICS ENGINEERING II, 2013, 684 : 111 - +
  • [39] Behaviour of a Cold-Formed Steel Shear Wall with Centre-Corrugated Steel Sheathing under Cyclic Loading
    Xie, Zhiqiang
    Shi, Leilei
    Peng, Lingyun
    Zhang, Shi
    Zhou, Daxing
    Zhang, Xiangdong
    Yu, Cheng
    ENGINEERING STRUCTURES, 2024, 318
  • [40] Performance of cyclic loading for structural insulated panels in wall application
    Nah, Hwan-Seon
    Lee, Hyeon-Ju
    Choi, Sung-Mo
    STEEL AND COMPOSITE STRUCTURES, 2013, 14 (06): : 587 - 604