Exploring new frontiers: a rare case of catheter ablation for persistent atrial fibrillation in a patient with cor triatriatum sinister guided by intracardiac echocardiography

被引:0
|
作者
Lai, Hengli [1 ]
Wu, Bo [1 ,2 ]
Tao, Yu [1 ]
Ding, Haiqiang [1 ]
Liu, Yanfeng [1 ]
Zhu, Zhiyun [1 ]
Huang, Xiantao [1 ]
Li, Hongyan [1 ]
Xu, Zhicheng [1 ]
Chen, Zhenhuan [1 ]
Zhou, Haiwen [1 ]
机构
[1] Jiangxi Prov Peoples Hosp, Affiliated Hosp 1, Nanchang Med Coll, Dept Cardiol, Nanchang 330006, Jiangxi, Peoples R China
[2] Nanchang Univ, Jiangxi Med Coll, Nanchang 330006, Jiangxi, Peoples R China
关键词
Cor triatriatum sinister; Persistent atrial fibrillation; Intracardiac echocardiography; Catheter ablation;
D O I
10.1186/s13019-024-02859-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cor triatriatum sinister (CTS) is an uncommon congenital cardiac anomaly. Atrial fibrillation (AF) is commonly the initial symptom in patients with CTS, occurring in approximately 32% of the cases. The complexity of performing AF catheter ablation, particularly in cases with persistent AF, increases in patients with CTS due to its unique structural challenges.Case presentation We report the treatment course of a 60-year-old male patient diagnosed with CTS, who underwent catheter ablation of drug-refractory, persistent AF. The complex anatomical structure of the condition made catheter ablation of AF challenging. To navigate these challenges, we performed comprehensive assessments using transthoracic echocardiography and transesophageal echocardiography, along with cardiac computed tomography angiography, prior to treatment initiation. The intricate anatomy of CTS was further clarified during the procedure via intracardiac echocardiography (ICE). Additionally, the complexity of catheter manipulation was further reduced with the aid of the VIZIGO sheath and the vein of Marshall ethanol infusion to achieve effective mitral isthmus blockage, thereby circumventing the impact of the CTS membrane.Conclusions This case underscores the complexity and potential of advanced ablation techniques in managing cardiac arrhythmias associated with unusual cardiac anatomies. During the procedure, ICE facilitated detailed modeling of the left atrium, including the membranous structure and its openings, thus providing a clearer understanding of CTS. It is noteworthy that the membrane within the CTS may serve as a potential substrate for arrhythmias, which warrants further validation through larger sample studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Cor triatriatum sinister presenting with adult onset atrial fibrillation-Another rare cause for a common clinical problem
    Ker, James
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (01) : E12 - E13
  • [32] Conservative approach for patient in acute heart failure with cor triatriatum dexter and atrial fibrillation: A rare case report
    Winata, S. M.
    Rasmin, R.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2016, 18 (0B) : B55 - B55
  • [33] Conservative approach for patient in acute heart failure with cor triatriatum dexter and atrial fibrillation : a rare case report
    Winata, S. M. Satyadharma Michael
    EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 61 - 61
  • [34] Prevention of esophageal injury during catheter ablation of atrial fibrillation: Is intracardiac echocardiography the answer?
    Calkins, Hugh
    HEART RHYTHM, 2006, 3 (10) : 1162 - 1163
  • [35] Catheter Ablation of Atrial Fibrillation Without Fluoroscopy Using Intracardiac Echocardiography and Electroanatomic Mapping
    Ferguson, John D.
    Helms, Adam
    Mangrum, J. Michael
    Mahapatra, Srijoy
    Mason, Pamela
    Bilchick, Ken
    McDaniel, George
    Wiggins, David
    DiMarco, John P.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (06): : 611 - U28
  • [36] Use of intracardiac echocardiography in vein of Marshall ethanol infusion for ablation of persistent atrial fibrillation
    Ding, Xueyan
    Wang, Li
    Liu, Qiang
    Chen, Shiquan
    Jiang, Ruhong
    Yu, Lu
    Zhang, Pei
    Lin, Jianwei
    Sun, Yaxun
    Sheng, Xia
    Fu, Guosheng
    Zei, Paul C.
    Jiang, Chenyang
    HEART RHYTHM, 2024, 21 (03) : 274 - 281
  • [37] Shear Wave Elastography With Intracardiac Echocardiography Characterizes Atrial Stiffness During Catheter Ablation For Atrial Fibrillation
    Kim, Young-Joong
    Wolf, Patrick D.
    Bahnson, Tristram D.
    CIRCULATION, 2019, 140
  • [38] Electrogram morphology recurrence guided catheter ablation for repeat ablation of persistent atrial fibrillation
    Raul D. Mitrani
    Ghaith Zaatari
    Jorge Bohorquez
    Jason Ng
    Justin Ng
    Harold Rivner
    Alex Velasquez
    Litsa Lambrakos
    Rishi Arora
    Jeffrey J. Goldberger
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 183 - 191
  • [39] Electrogram morphology recurrence guided catheter ablation for repeat ablation of persistent atrial fibrillation
    Mitrani, Raul D. D.
    Zaatari, Ghaith
    Bohorquez, Jorge
    Ng, Jason
    Ng, Justin
    Rivner, Harold
    Velasquez, Alex
    Lambrakos, Litsa
    Arora, Rishi
    Goldberger, Jeffrey J. J.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (01) : 183 - 191
  • [40] Echocardiographic guidance of pulmonary vein isolation catheter ablation procedure for recurrent atrial fibrillation in partial cor triatriatum
    Paelinck, Bernard P.
    Van Herck, Paul L.
    Vandaele, Lien
    Sarkozy, Andrea
    KARDIOLOGIA POLSKA, 2018, 76 (11) : 1575 - 1575