Enhancement of Diagnostic Accuracy in Endometrial Carcinoma using CW-THz Spectroscopy

被引:0
|
作者
Umadevi, Kovuri [1 ,2 ]
Sundeep, Dola [3 ]
Latha, A. Mercy [4 ]
Kumari, Sarita [5 ,6 ]
Varadharaj, Eswaramoorthy K. [2 ]
Sastry, C. Chandrasekhara [7 ]
Vighnesh, Alluru Raghavendra [8 ]
Ali, Mohd. Imran [1 ]
Krishna, Alluru Gopala [9 ]
机构
[1] Govt Med Coll & Hosp, Dept Pathol, Nizamabad 503001, Telangana, India
[2] Amrita Sch Med, Dept Pathol, Ernakulam 682041, Kerala, India
[3] Indian Inst Informat Technol Design & Mfg, Dept Elect & Commun Engn, Biomed Res Lab, Jagannathagattu Hill, Kurnool 518008, Andhra Pradesh, India
[4] CSIR, Cent Elect Engn Res Inst, Chennai Ctr, Csir Madras Complex, Chennai 600113, India
[5] All India Inst Med Sci, Dept Obstet & Gynaecol, New Delhi 110049, India
[6] Kolkata Gynecol Oncol Trials & Translat Res Grp, Kolkata 700026, West Bengal, India
[7] Indian Inst Informat Technol Design & Mfg, Dept Mech Engn, Biomed Res Lab, Jagannathagattu Hill, Kurnool 518008, Andhra Pradesh, India
[8] Indian Inst Technol IIT BHU, Dept Mech Engn, Varanasi 221005, Uttar Pradesh, India
[9] Jawaharlal Nehru Technol Univ Kakinada, Dept Mech Engn, Kakinada 503003, Andhra Pradesh, India
关键词
Terahertz; Endometrial cancer; Early detection; Nonionizing and medical imaging; CANCER; OBESITY;
D O I
10.1007/s40944-024-00872-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background and ObjectiveTerahertz (THz) spectroscopy has emerged as a cutting-edge tool for advancing cancer imaging research. The objective of this study was to utilize an advanced high-resolution continuous-wave terahertz (CW-THz) imaging system to ex vivo image human endometrial cancer (EC) on unstained, formalin-fixed, and paraffin-embedded histopathology slides. The aim was to localize EC and distinguish cancerous EC tissue from the surrounding noncancerous myometrial tissue.Materials and MethodsAn advanced high-resolution continuous-wave terahertz (CW-THz) imaging system was employed to image ex vivo human endometrial cancer (EC) on unstained, formalin-fixed, and paraffin-embedded histopathology slides. The terahertz spectroscopy data were meticulously processed to generate 2-D transmission THz raw images. Sophisticated image processing techniques, including Gaussian filtering and resolution enhancement, were applied to improve image clarity.ResultsThe resulting THz images revealed a notable increase in terahertz absorption within the EC tissue compared to the surrounding myometrium. The enhanced contrast provided by the CW-THz imaging system was pivotal for delineating tumor boundaries, closely corroborating with histopathological results. The sophisticated image processing techniques significantly enhanced image clarity, facilitating the precise localization of EC.ConclusionsThis study demonstrates the promise of THz spectroscopy as a significant adjunct in cancer research, particularly in the diagnostic precision of endometrial endometrioid carcinoma. The high-resolution CW-THz imaging system effectively differentiated cancerous EC tissue from noncancerous myometrial tissue, suggesting its potential for improving diagnostic accuracy in clinical practice.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Novel Diagnostic Scheme Biomechanical Discrimination of Cells using THz-TD Transmission Spectroscopy
    Kundu, Urbi
    Bandyopadhyay, Aparajita
    Sengupta, Amartya
    EMERGING TECHNOLOGIES FOR CELL AND TISSUE CHARACTERIZATION, 2021, 11921
  • [32] Diagnostic accuracy of Raman spectroscopy in oral squamous cell carcinoma (vol 12, 925032, 2022)
    Han, Ruiying
    Lin, Nan
    Huang, Juan
    Ma, Xuelei
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [33] The Diagnostic accuracy of transvaginal ultrasonography, magnetic resonance imaging and diffusion weighted image in female patients with endometrial carcinoma
    Mohamed, Dina Moghazy
    Dewan, Khaled Abd El-Wahab Abo
    Mera, Salwa Mahmoud
    ALEXANDRIA JOURNAL OF MEDICINE, 2018, 54 (04) : 685 - 691
  • [34] Diagnostic accuracy for drug detection using liquid chromatography/mass spectroscopy in overdose patients
    Yagihashi, Gen
    Tarui, Takehiko
    Miyagi, Hiroyuki
    Ohnishi, Hiroaki
    Watanabe, Takashi
    Yamaguchi, Yoshihiro
    ACUTE MEDICINE & SURGERY, 2020, 7 (01):
  • [35] Improvement of diagnostic accuracy of transvaginal ultrasound for identification of endometrial malignancies by using cutoff level of endometrial thickness based on length of time since menopause
    Tsuda, H
    Kawabata, M
    Kawabata, K
    Yamamoto, K
    Umesaki, N
    GYNECOLOGIC ONCOLOGY, 1997, 64 (01) : 35 - 37
  • [36] Accuracy Enhancement of Raman Spectroscopy Using Complementary Laser-Induced Breakdown Spectroscopy (LIBS) with Geologically Mixed Samples
    Choi, Soojin
    Kim, Dongyoung
    Yang, Junho
    Yoh, Jack J.
    APPLIED SPECTROSCOPY, 2017, 71 (04) : 678 - 685
  • [37] Diagnostic Accuracy of Clinical Biomarkers for Preoperative Prediction of Lymph Node Metastasis in Endometrial Carcinoma: A Systematic Review and Meta-Analysis
    Reijnen, Casper
    IntHout, Joanna
    Massuger, Leon F. A. G.
    Strobbe, Fleur
    Kusters-Vandevelde, Heidi V. N.
    Haldorsen, Ingfrid S.
    Snijders, Marc P. L. M.
    Pijnenborg, Johanna M. A.
    ONCOLOGIST, 2019, 24 (09): : E880 - E890
  • [38] Diagnostic accuracy and molecular characterization of endometrial cancer using hybrid [18F]FDG PET/MRI
    Bezzi, C.
    Russo, T.
    Candotti, G.
    Bergamini, A.
    Ironi, G.
    Sabini, C.
    Fallanca, F.
    Ghezzo, S.
    Gajate, A. M. Samanes
    Bocciolone, L.
    Scifo, P.
    Taccagni, G. L.
    Mangili, G.
    Candiani, M.
    De Cobelli, F.
    Chiti, A.
    Mapelli, P.
    Picchio, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S330 - S330
  • [39] Results of a prospective study on the diagnostic accuracy of sentinel node in endometrial cancer by using hysteroscopic injection of radiolabelled tracer
    Maccauro, M.
    Solima, E.
    Aliberti, G.
    Seregni, E.
    Martinelli, F.
    Castellani, M.
    Setti, L.
    Raspagliesi, F.
    Bombardieri, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S213 - S213
  • [40] Identification of intraductal carcinoma of the prostate on tissue specimens using Raman micro-spectroscopy: A diagnostic accuracy case-control study with multicohort validation
    Grosset, Andree-Anne
    Dallaire, Frederick
    Tien Nguyen
    Birlea, Mirela
    Wong, Jahg
    Daoust, Francois
    Roy, Noemi
    Kougioumoutzakis, Andre
    Azzi, Feryel
    Aubertin, Kelly
    Kadoury, Samuel
    Latour, Mathieu
    Albadine, Roula
    Prendeville, Susan
    Boutros, Paul
    Fraser, Michael
    Bristow, Rob G.
    van der Kwast, Theodorus
    Orain, Michele
    Brisson, Herve
    Benzerdjeb, Nazim
    Hovington, Helene
    Bergeron, Alain
    Fradet, Yves
    Tetu, Bernard
    Saad, Fred
    Leblond, Frederic
    Trudel, Dominique
    PLOS MEDICINE, 2020, 17 (08)