Research on the effects of resonance tube bending in loop thermoacoustic refrigeration system

被引:1
|
作者
Ding, Xiachen [1 ]
Kang, Huifang [1 ]
Sun, Xiaoxia [2 ]
Jiang, Yifan [1 ]
Zhang, Lingxiao [1 ]
机构
[1] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
[2] China North Vehicle Res Inst, Beijing 100072, Peoples R China
关键词
Resonance tube; Curvature; Arc length; Traveling -standing wave ratio; Acoustic power dissipation; Minor losses; OSCILLATING FLOW-THROUGH; DISSIPATION; LOSSES;
D O I
10.1016/j.applthermaleng.2024.122985
中图分类号
O414.1 [热力学];
学科分类号
摘要
A high-power-density heat-driven loop thermoacoustic refrigeration system has the potential to meet miniaturization requirements of vehicle waste heat recovery systems. Given the strict space constraints in vehicle power compartments and the need to reduce equipment footprint, the resonance tubes need to be bent and coiled. However, the introduction of curvature may increase losses in resonance tubes. In order to evaluate the minor losses caused by bending on resonance tubes, a double-acoustic-source driven acoustic field modulation platform was constructed to experimentally investigate bent resonance tubes with different arc lengths under two common bending angles (90 degrees and 180 degrees) under high working pressure. Through the acoustic field reconstruction method, the acoustic field distributions of each resonance tube were obtained, and the effects of changes in bending angle and arc length on acoustic field and acoustic power dissipation were analyzed. The results indicated that the introduction of curvature leads to an increase in traveling-standing wave ratio, acoustic power, and acoustic power dissipation, with the degree of increase influenced by both curvature and arc length. Under the same bending angle, the minor loss is directly proportional to curvature, and there is an ExpAssoc function relationship between minor loss coefficient and curvature. Under the same curvature, the minor loss is not proportional to arc length, and minor loss coefficient slightly increases with the arc length doubles. The findings fill the research gap in resonance tube bending in loop thermoacoustic systems and provide guidance for the selection of resonance tube bending parameters.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Miniaturization of the Loop-Tube-Type Thermoacoustic Cooling System: Effect of the Installation Position of Heat Pump and Working Gas in the Tube
    Hotta, Kohei
    Sakamoto, Shin-ichi
    Tsukamoto, Daichi
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (07)
  • [22] Eliminating nonlinear acoustical effects from thermoacoustic refrigeration systems
    Garrett, Steven L.
    Smith, Robert W. M.
    Poese, Matthew E.
    INNOVATIONS IN NONLINEAR ACOUSTICS, 2006, 838 : 407 - +
  • [23] Combined Experimental and Numerical Study on the Performance of Thermoacoustic Refrigeration System
    Khan, Md. Ikram
    Siddiqui, Tahmid Rakin
    Rahman, Md. Ashiqur
    8TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2019, 2121
  • [24] Improvement of cooling effect of loop-tube-type thermoacoustic cooling system applying phase adjuster
    Sakamoto, Shin-Ichi
    Imamura, Yosuke
    Watanabe, Yoshiaki
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2007, 46 (7 B): : 4951 - 4955
  • [25] Measurement of temperature gradient in a stack of a prime mover in a loop-tube-type thermoacoustic cooling system
    Sakamoto, Shin-ichi
    Inui, Yoshitaka
    Watanabe, Yoshiaki
    NONLINEAR ACOUSTICS: STATE-OF-THE-ART AND PERSPECTIVES (ISNA 19), 2012, 1474 : 304 - 307
  • [26] Improvement of cooling effect of loop-tube-type thermoacoustic cooling system applying phase adjuster
    Sakamoto, Shin-Ichi
    Imamura, Yosuke
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (7B): : 4951 - 4955
  • [27] Effect of an external sound superimposed on the self-excited oscillation in a loop-tube thermoacoustic system
    Hiramatsu, Koto
    Sakamoto, Shin-ichi
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (SG)
  • [28] Experimental investigation of the effects of driver housing and resonance tube on the temperature difference across a thermoacoustic stack
    Channarong Wantha
    Kriengkrai Assawamartbunlue
    Heat and Mass Transfer, 2013, 49 : 887 - 896
  • [29] Experimental investigation of the effects of driver housing and resonance tube on the temperature difference across a thermoacoustic stack
    Wantha, Channarong
    Assawamartbunlue, Kriengkrai
    HEAT AND MASS TRANSFER, 2013, 49 (06) : 887 - 896
  • [30] Influence of resonance tube geometry shape on performance of thermoacoustic engine
    Bao, Rui
    Chen, Guobang
    Tang, Ke
    Jia, Zhengzhong
    Cao, Weihua
    ULTRASONICS, 2006, 44 (e1519-e1521) : E1519 - E1521