Exergy analysis for enhanced performance of integrated batch reverse osmosis - Forward osmosis system for brackish water treatment

被引:3
|
作者
Patel, Dhaval [1 ]
Mudgal, Anurag [1 ]
Patel, Vivek [1 ]
Patel, Jatin [1 ]
Park, Kiho [2 ]
Davies, Philp [3 ]
Dhakal, Nirajan [4 ]
机构
[1] Pandit Deendayal Energy Univ, Sch Technol, Mech Engn Dept, Gandhinagar, India
[2] Hanyang Univ, Dept Chem Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[3] Univ Birmingham, Sch Engn, Birmingham B15 2TT, England
[4] IHE Delft, Dept Water Supply Sanitat & Environm Engn, West Vest 7, NL-2611 AX Delft, Netherlands
关键词
Batch reverse osmosis; Forward osmosis; Fresh water cost; Specific solution cost; Specific energy consumption; Economic; ENERGY-CONSUMPTION; DESALINATION; SEAWATER; RO; HYBRID; OPTIMIZATION; COST; DESIGN;
D O I
10.1016/j.desal.2024.117548
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Concept of integrated brackish water batch reverse osmosis - forward osmosis (BRO - FO) is relatively new in the field of desalination. Recovery of the reverse osmosis (RO) system can be elevated using the free piston BRO concept, and the specific energy consumption (SEC) can be reduced. This study focuses on exergy, advanced exergy, and parametric analysis of the integrated BRO - FO system. The conventional exergy analysis suggests that the largest rate of exergy destruction is associated with the system's RO membrane module and pump, with values of 6.51 and 87.06 %, respectively. However, advanced exergy analysis shows that this rate can be reduced by 3.53 % and 62.89 %, respectively. Endogenous exergy destruction of pumps and membranes is higher compared to exogenous exergy destruction. These results are utilised to determine the system's optimal performance using parametric analysis. Sensitivity analysis was utilised to obtain an optimum recovery for system design, fresh water cost (FWC), and specific solution cost (SSC). The BRO can achieve >80 % recovery with 0.43 kWh/m(3) SEC, and FO technology helps to attain minimal/zero waste discharge. Thus, a FWC of 0.50 $/m(3) and a SWC of 0.44 $/m(3) can be achieved.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] REVERSE-OSMOSIS PILOT PLANTS PERFORMANCE IN BRACKISH WATER DESALINATION
    BOARI, G
    CARRIERI, C
    MAPPELLI, P
    SANTORI, M
    [J]. DESALINATION, 1978, 24 (1-3) : 341 - 364
  • [22] Integrated reverse osmosis/vacuum membrane distillation for enhanced arsenic removal and water recovery of brackish water desalination
    Dao, Duong Thanh
    Duong, Hung Cong
    Laborie, Stephanie
    Cabassud, Corinne
    [J]. DESALINATION AND WATER TREATMENT, 2023, 287 : 19 - 28
  • [23] Optimization of forward osmosis system for the utilization of reverse osmosis brine
    Christian Eusebio, Ramon
    Angelo Promentilla, Michael
    Kim, Han Seung
    [J]. DESALINATION AND WATER TREATMENT, 2016, 57 (57) : 27899 - 27904
  • [24] Process for high recovery treatment of brackish water reverse osmosis concentrate
    Franzsen, Sebastian
    Sheridan, Craig
    Simate, Geoffrey S.
    [J]. DESALINATION, 2021, 498
  • [25] Performance of a hybrid reverse osmosis-constructed wetland treatment system for brackish oil field produced water
    Murray-Gulde, C
    Heatley, JE
    Karanfil, T
    Rodgers, JH
    Myers, JE
    [J]. WATER RESEARCH, 2003, 37 (03) : 705 - 713
  • [26] THERMODYNAMIC ANALYSIS OF A REVERSE OSMOSIS DESALINATION SYSTEM USING FORWARD OSMOSIS FOR ENERGY RECOVERY
    Banchik, Leonardo D.
    Lienhard, John H., V
    [J]. INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 1017 - 1029
  • [27] Effect of Electric Field on Membrane Fouling and Membrane Performance in Reverse Osmosis Treatment of Brackish Water
    Fu, Caixia
    Yi, Xuenong
    Gao, Yuqiong
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (02):
  • [28] Exergy analysis of a seawater reverse osmosis plant
    Romero-Ternero, V
    García-Rodríguez, L
    Gómez-Camacho, C
    [J]. DESALINATION, 2005, 175 (02) : 197 - 207
  • [29] Serially connected forward osmosis membrane elements of pressure-assisted forward osmosis-reverse osmosis hybrid system: Process performance and economic analysis
    Kook, Seungho
    Lee, Chulmin
    Thanh Tin Nguyen
    Lee, Jangho
    Shon, Ho Kyong
    Kim, In S.
    [J]. DESALINATION, 2018, 448 : 1 - 12
  • [30] Reverse osmosis for water treatment
    CSM GmbH & Co KG, Bretten-Goelshausen, Germany
    [J]. Melliand Text, 10 (1 pp):