Two-stage robust optimization of unified power quality conditioner (UPQC) siting and sizing in active distribution networks considering uncertainty of loads and renewable generators

被引:1
|
作者
Zhu, Xiaoguang [1 ]
Guo, Yubo [2 ]
Li, Ao [1 ]
Li, Shurong [1 ]
Zhang, Juning [1 ]
Gu, Borui [1 ]
Deng, Junbo [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Tsinghua Univ, Sichuan Energy Internet Res Inst, Chengdu 610299, Peoples R China
基金
中国国家自然科学基金;
关键词
Unified power quality conditioner (UPQC); Renewable energy; Siting and sizing allocation; Two-stage robust optimization; Mixed integer second-order conic programming; RADIAL-DISTRIBUTION NETWORKS; FLOW MODEL RELAXATIONS; OPTIMAL LOCATION; ENERGY-LOSS; ALLOCATION; CAPACITY; COMPENSATION; SYSTEM; WIND;
D O I
10.1016/j.renene.2024.120197
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper proposes a robust optimization siting and sizing strategy for the unified power quality conditioner (UPQC) in the active distribution network (ADN) integrated with renewable energy generators. The optimization objectives including investment cost, line loss, and voltage deviation are integrated into an overall cost for both the planning and operating stages. A novel UPQC equivalent power injection model is proposed based on the auxiliary branch method. A set of linear and second-order conic (SOC) constraints are employed to accurately describe the steady -state operation of UPQC. An improved branch current flow model is developed to incorporate radial distribution networks with UPQCs. The UPQC siting and sizing planning is formulated as a mixed integer second-order conic programming (MISOCP) problem. Accounting for the uncertainty in loads and distributed generators, a two-stage robust optimization model is established to address worst-case operational scenarios. A solving strategy is developed based on the strong duality theory and the column-and-constraint generation (C&CG) algorithm, and then commercial solvers can solve the problem accurately and efficiently. Case studies on an IEEE 33 -node distribution network demonstrate this strategy's robustness in dealing with loads and renewable energy uncertainties, making it applicable across different UPQC topologies and operation modes. The proposed method has superior performance over the representative meta-heuristic approaches in terms of global optimality as well as an over 7.5 times faster computation speed. This work has significance in enhancing the quality and efficiency of modern power systems highly integrated with renewable energy.
引用
收藏
页数:17
相关论文
共 13 条
  • [1] A Two-Stage Robust Reactive Power Optimization Considering Uncertain Wind Power Integration in Active Distribution Networks
    Ding, Tao
    Liu, Shiyu
    Yuan, Wei
    Bie, Zhaohong
    Zeng, Bo
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (01) : 301 - 311
  • [2] A two-stage optimal scheduling method for active distribution networks considering uncertainty risk
    Ma, Hengrui
    Liu, Zhe
    Li, Min
    Wang, Bo
    Si, Yang
    Yang, Yan
    Mohamed, Mohamed A.
    [J]. ENERGY REPORTS, 2021, 7 : 4633 - 4641
  • [3] TWO-STAGE DYNAMIC ROBUST RECONFIGURATION METHOD OF ACTIVE DISTRIBUTION NETWORK CONSIDERING DG UNCERTAINTY
    Jin P.
    Song W.
    Liu Y.
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (06): : 208 - 216
  • [4] Two-stage optimization strategy for the active distribution network considering source-load uncertainty
    Fang, Yong
    Mu, Yi
    Liu, Chun
    Yang, Xiaodong
    [J]. Energy Informatics, 2024, 7 (01)
  • [5] Fast Solving Method for Two-Stage Multi-Period Robust Optimization of Active and Reactive Power Coordination in Active Distribution Networks
    Zhang, Jian
    He, Yigang
    [J]. IEEE ACCESS, 2023, 11 : 30208 - 30222
  • [6] Two-stage robust optimization for expansion planning of active distribution systems coupled with urban transportation networks
    Xie, Shiwei
    Hu, Zhijian
    Wang, Jueying
    [J]. APPLIED ENERGY, 2020, 261
  • [7] A Two-Stage Robust Optimization for Centralized-Optimal Dispatch of Photovoltaic Inverters in Active Distribution Networks
    Ding, Tao
    Li, Cheng
    Yang, Yongheng
    Jiang, Jiangfeng
    Bie, Zhaohong
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2017, 8 (02) : 744 - 754
  • [8] Two-Stage Robust Design of Resilient Active Distribution Networks Considering Random Tie Line Outages and Outage Propagation
    Wang, Chongyu
    Pang, Kaiyuan
    Shahidehpour, Mohammad
    Wen, Fushuan
    Duan, Shuyin
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (04) : 2630 - 2644
  • [9] Two-Stage Robust Sizing and Operation Co-Optimization for Residential PVx2013;Battery Systems Considering the Uncertainty of PV Generation and Load
    Aghamohamadi, Mehrdad
    Mahmoudi, Amin
    Haque, Mohammed H.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (02) : 1005 - 1017
  • [10] Two-stage reactive power chance-constrained optimization method for an active distribution network considering DG uncertainties
    Lu, Ji
    Chang, Junxiao
    Zhang, Yunge
    E, Shiping
    Zeng, Chuihui
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (21): : 28 - 35