Real-time visualization of dextran extravasation in intermittent hypoxia mice using noninvasive SWIR imaging

被引:0
|
作者
Le Guevel, Xavier [1 ]
Josserand, Veronique [1 ]
Harki, Olfa [2 ]
Baulin, Vladimir A. [3 ]
Henry, Maxime [1 ]
Briancon-Marjollet, Anne [2 ]
机构
[1] Univ Grenoble Alpes, Inst Adv Biosci, NSERM1209, CNRS,UMR5309, Grenoble, France
[2] Univ Grenoble Alpes, Lab HP2, INSERM, U1300, Grenoble, France
[3] Univ Rovira & Virgili, Dept Quim Fis & Inorgan, Tarragona, Spain
关键词
dextran extravasation; intermittent hypoxia; SWIR imaging; vessel permeability; BRAIN; MODEL;
D O I
10.1152/ajpheart.00787.2023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Imaging tools are crucial for studying the vascular network and its barrier function in various physiopathological conditions. Shortwave infrared (SWIR) window optical imaging allows noninvasive, in-depth exploration. We applied SWIR imaging, combined with vessel segmentation and deep learning analyses, to study real-time dextran probe extravasation in mice experiencing intermittent hypoxia (IH)-a characteristic of obstructive sleep apnea associated with potential cardiovascular alterations due to early vascular permeability. Evidence for permeability in this context is limited, making our investigation significant. C57Bl/6 mice were exposed to normoxia or intermittent hypoxia for 14 days. Then SWIR imaging between 1,250 and 1,700 nm was performed on the saphenous artery and vein and on the surrounding tissue after intravenous injection of labeled dextrans of two different sizes (10 or 70 kDa). Postprocessing and segmentation of the SWIR images were conducted using deep learning treatment. We monitored high-resolution signals, distinguishing arteries, veins, and surrounding tissues. In the saphenous artery and vein, after 70-kD dextran injection, tissue/vessel ratio was higher after intermittent hypoxia (IH) than normoxia (N) over 500 seconds (P < 0.05). However, the ratio was similar in N and IH after 10-kD dextran injection. The SWIR imaging technique allows noninvasive, real-time monitoring of dextran extravasation in vivo. Dextran 70 extravasation is increased after exposure to IH, suggesting an increased vessel permeability in this mice model of obstructive sleep apnea. NEW & NOTEWORTHY We demonstrate that SWIR imaging technique is a useful tool to monitor real-time dextran extravasation from vessels in vivo, with a high resolution. We report for the first time an increased real-time dextran (70 kD) extravasation in mice exposed to intermittent hypoxia for 14 days compared with normoxic controls.
引用
收藏
页码:H900 / H906
页数:7
相关论文
共 50 条
  • [1] Noninvasive real-time imaging of atherosclerosis in mice using ultrasound biomicroscopy
    Gan, LM
    Grönros, J
    Hägg, U
    Wilkström, J
    Fritsche-Danielsson, R
    CIRCULATION, 2004, 110 (17) : 374 - 375
  • [2] Real-Time SWIR Hyperspectral Imaging with Polarimetric Capability
    Wong, Gerald
    Harvey, Andrew R.
    Pilkington, Roger
    Rickman, Rick
    IMAGING SPECTROMETRY XV, 2010, 7812
  • [3] Noninvasive real-time imaging of apoptosis
    Laxman, B
    Hall, DE
    Bhojani, MS
    Hamstra, DA
    Chenevert, TL
    Ross, BD
    Rehemtulla, A
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (26) : 16551 - 16555
  • [4] In Situ, Real-Time Visualization of Electrochemistry Using Magnetic Resonance Imaging
    Britton, Melanie M.
    Bayley, Paul M.
    Howlett, Patrick C.
    Davenport, Alison J.
    Forsyth, Maria
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2013, 4 (17): : 3019 - 3023
  • [5] NONINVASIVE VISUALIZATION OF INTRACARDIAC SHUNT FLOWS BY REAL-TIME TWO-DIMENSIONAL DOPPLER FLOW IMAGING
    NIMURA, Y
    MIYATAKE, K
    KINOSHITA, N
    OKAMOTO, M
    IZUMI, S
    SAKAKIBARA, H
    CIRCULATION, 1984, 70 (04) : 406 - 406
  • [6] Software visualization techniques for real-time imaging applications
    Sangwan, R
    Ludwig, R
    Neill, CJ
    Real-Time Imaging IX, 2005, 5671 : 30 - 35
  • [7] Noninvasive and real-time pharmacokinetics imaging of polymeric nanoagents in the thoracoepigastric vein networks of living mice
    Wang, Chuan-Xi
    Gao, Zhi-Yue
    Wang, Xin
    Ke, Can
    Zhang, Zhuo
    Zhang, Chao-Jie
    Fu, Li-Min
    Wang, Yuan
    Zhang, Jian-Ping
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (06)
  • [8] Real-time visualization of renal microperfusion using laser speckle contrast imaging
    Heeman, Wido
    Maassen, Hanno
    Calon, Joost
    van Goor, Harry
    Leuvenink, Henri
    van Dam, Gooitzen M.
    Boerma, E. Christiaan
    JOURNAL OF BIOMEDICAL OPTICS, 2021, 26 (05)
  • [9] Scalable Real-Time Visualization Using the Cloud
    Holliman, Nick
    Watson, Paul
    IEEE CLOUD COMPUTING, 2015, 2 (06): : 90 - 96
  • [10] Noninvasive real-time mapping of an incomplete pulmonary vein isolation using electrocardiographic imaging
    Cuculich, Phillip S.
    Wang, Yong
    Lindsay, Bruce D.
    Vijayakumar, Ramya
    Rudy, Yoram
    HEART RHYTHM, 2010, 7 (09) : 1316 - 1317