Are Implant Threads Important for Implant Stability? An In Vitro Study Using Low-Density Polyurethane Sheets

被引:5
|
作者
Comuzzi, Luca [1 ]
Tumedei, Margherita [1 ]
Di Pietro, Natalia [2 ,3 ]
Romasco, Tea [2 ,3 ]
Montesani, Lorenzo [5 ]
Piattelli, Adriano [4 ]
Covani, Ugo [5 ]
机构
[1] Univ Milan, Dept Med Surg & Dent, I-20122 Milan, Italy
[2] G Annunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66013 Chieti, Italy
[3] G Annunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, Chieti, Italy
[4] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[5] Versilia Gen Hosp, Tuscan Dent Inst, I-55041 Lido Di Camaiore, Italy
来源
ENG | 2023年 / 4卷 / 02期
关键词
conical implants; cylindrical implants; implant apex; implant stability quotient; implant threads; insertion torque; polyurethane; post-extraction; primary stability; removal torque; INSERTION TORQUE; QUALITY; SURFACE; DESIGN; DRILL;
D O I
10.3390/eng4020068
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Different strategies are known to improve implant primary stability (PS) and the bone-to-implant contact in post-extractive conditions, such as the macro-geometry of screws and apical threads, which can enhance the mechanical characteristics. In any case, the role of the apical area design in maintaining or improving the PS, especially in low-quality bone, still remains unclear. Thus, the present study aimed at evaluating in vitro the Insertion Torque (IT), Removal Torque (RT), and Resonance Frequency Analysis (RFA) of different implant apical threads in a cylindrical (EE) and in three conical implants (T3, TAC, Intra-lock) inserted in simulated post-extraction conditions on low-density polyurethane foams of 10 and 20 pounds per cubic foot (PCF), with and without the addition of a cortical sheet of 30 PCF in density. The IT, RT, and RFA values of all the implants tested were directly proportional to the polyurethane density and to the presence of the cortical sheet, but TAC and Intra-lock implants, which had the latest-generation thread design, always showed significantly higher values (e.g., IT: 18.6 and 18.6 Ncm, RT: 10.8 and 13.7 Ncm, RFA mean: 46 and 43 ISQ, in the 20 PCF density with the cortical sheet for TAC and Intra-lock, respectively). In particular, TAC implants also reached the highest RFA values in the lowest-density foam (19 ISQ). In conclusion, the present in vitro study demonstrated that TAC and Intra-lock apical designs and macro-geometries could play a key role in determining the PS and the polyurethane-implant contact in simulated post-extraction conditions in low-density artificial bone.
引用
收藏
页码:1167 / 1178
页数:12
相关论文
共 50 条
  • [1] Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study
    Degidi, Marco
    Daprile, Giuseppe
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 334 - 337
  • [2] Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
    Wakamatsu, Kaien
    Doi, Kazuya
    Kobatake, Reiko
    Oki, Yoshifumi
    Tsuga, Kazuhiro
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (06):
  • [3] The primary stability of two dental implant systems in low-density bone
    Heitzer, M.
    Kniha, K.
    Katz, M. S.
    Winnand, P.
    Peters, F.
    Moehlhenrich, S. C.
    Hoelzle, F.
    Modabber, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 51 (08) : 1093 - 1100
  • [4] Impaction technique influences implant stability in low-density bone model
    Doyle, R.
    van Arkel, R. J.
    Muirhead-Allwood, S.
    Jeffers, J. R. T.
    BONE & JOINT RESEARCH, 2020, 9 (07): : 386 - 393
  • [5] Influence of different implant placement techniques to improve primary implant stability in low-density bone: A systematic review
    Palaskar, Jayant N.
    Joshi, Nikhil
    Shah, Pooja M.
    Gullapalli, Poorva
    Vinay, Vineel
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (01): : 11 - 16
  • [6] Validation of the Implant Stability Test for Implant Provisional Crowns: An In Vitro Study
    Okuhama, Yurie
    Nagata, Koudai
    Nakashizu, Toshifumi
    Wakamori, Kana
    Okubo, Manabu
    Tsuruoka, Hayato
    Kawana, Hiromasa
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [7] The Effect of Threads Geometry on Insertion Torque (IT) and Periotest Implant Primary Stability: A High-Density Polyurethane Simulation for the Anterior Mandible
    Fanali, Stefano
    Tumedei, Margherita
    Pignatelli, Pamela
    Petrini, Morena
    Piattelli, Adriano
    Iezzi, Giovanna
    CRYSTALS, 2021, 11 (03):
  • [8] LOW-DENSITY LIPOPROTEIN (LDL) ADSORPTION TO CARDIOVASCULAR IMPLANT MATERIALS
    DONG, DE
    ANDRADE, JD
    COLEMAN, DL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 102 - POLY
  • [9] The effect of implant length and diameter on primary stability of tilted implant on D4 bone density: An in vitro study
    Baihaqi, Muhammad, I
    Sumarsongko, Taufik
    Bonifacius, Setyawan
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (05): : 487 - 493
  • [10] Evaluation of Implant Stability and Trephination Depth for Implant Removal-An In Vitro Study
    Meir, Haya
    Sebaoun, Alon
    Raz, Perry
    Levartovsky, Shifra
    Arieli, Adi
    Pilo, Raphel
    Dor, Zafar
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (12)