Correlation Between Acquisition of Dental Implant Stability and Hounsfield Units at Dental Implant Placement

被引:1
|
作者
Takekawa, Takahiro [1 ]
Moroi, Akinori [1 ]
Gomi, Karen [1 ]
Takayama, Akihiro [1 ]
Yoshizawa, Kunio [1 ]
Ueki, Koichiro [1 ]
机构
[1] Univ Yamanashi, Grad Fac Interdisciplinary Res, Dept Oral & Maxillofacial Surg, Div Clin Med, Chuoshi, Japan
关键词
osseointegration; bone quality; Hounsfield unit; cortical bone; implant stability quotient; BONE QUALITY; COMPUTERIZED-TOMOGRAPHY; RESONANCE FREQUENCY; SECONDARY STABILITY; INSERTION TORQUE; DENSITY; DIAMETER; SURFACE;
D O I
10.1563/aaid-joi-D-22-00233
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Alveolar bone quality at the implantation site affects the initial stability of dental implant treatment. However, the relationship between bone quality and osseointegration has yet to be evaluated. Herein, we aimed to investigate the effect of bone quality on dental implant stability in osseointegration formation changes. Patients underwent computed tomography imaging before dental implantation at the posterior. Hounsfield units were measured at the platform, middle, and tip sites. Implant stability was measured using resonance frequency analysis immediately and at 3 months postoperatively, in which the difference in implant stability quotients (ISQ) was defined as the change between primary and secondary fixation. In multiple regression analysis, the dependent variable was the change between the immediate and secondary fixations. We included 81 implants that conformed to the criteria. Primary fixation yielded the following results: R2 = 0.117, F = 2.529, and P = .047. The difference between the maxilla and mandible of the implantation site (P = .02) and the platform -site Hounsfield units (P = .019) were identified as significant factors. The following results were obtained regarding the change between the immediate and secondary fixation: R2 = 0.714, F = 40.964, and P < .001. The difference between diameter (P = .008) and the immediate ISQ (P < .001) were identified as significant factors. Overall, the bone quality of the implantation site affected initial fixation; however, it had limited effect on secondary fixation. Our findings clarified the period where bone quality affects dental implant treatment and is expected to advance dental implant treatment.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [31] Antibiotic prophylaxis during dental implant placement in the UK
    Robert G. M. Williams
    British Dental Journal, 2020, 229 : 787 - 792
  • [32] Development of a Transducer for Dental Implant Stability Measurement
    Lin, Ming-Jer
    Tsai, Tung-Lin
    Wu, Xian-Ru
    Cheng, E-Hsung
    Yeh, Nan-Ming
    SENSORS, MECHATRONICS AND AUTOMATION, 2014, 511-512 : 265 - +
  • [33] On the use of EMI for the assessment of dental implant stability
    Ribolla, Emma La Malfa
    Rizzo, Piervincenzo
    Gulizzi, Vincenzo
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2014, 2014, 9064
  • [34] Nondestructive methods to assess dental implant stability
    Rizzo, Piervincenzo
    Tabrizi, Aydin
    Berhanu, Bruk
    Ochs, Mark W.
    NANOSENSORS, BIOSENSORS, AND INFO-TECH SENSORS AND SYSTEMS 2012, 2012, 8344
  • [35] BIOCOMPATIBILITY AND STABILITY OF A CANDIDATE DENTAL IMPLANT MATERIAL
    KAMEL, I
    GREENBERG, A
    DUBIN, S
    MILLER, A
    JOURNAL OF DENTAL RESEARCH, 1977, 56 : B80 - B80
  • [36] CORRELATIONS BETWEEN PHYSICAL PROPERTIES OF JAWBONE AND DENTAL IMPLANT INITIAL STABILITY
    Seong, Wook-Jin
    Kim, Uk-Kyu
    Swift, James Q.
    Hodges, James S.
    Ko, Ching-Chang
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (05): : 306 - 318
  • [37] Accuracy of an autonomous dental implant robotic system in dental implant surgery
    Wu, Yu
    Zou, Shiqi
    Lv, Pin
    Wang, Xiao
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 764 - 770
  • [39] The Association of Dental Caries or Dental Implant Placement Within One Year of Primary Total Hip Arthroplasty on Medical and Implant Complications
    Gordon, Adam M.
    Ng, Mitchell K.
    Magruder, Matthew L.
    Schwartz, Jake M.
    Wong, Che Hang Jason
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : 2295 - 2302
  • [40] Is panoramic radiograph really safe in the posterior mandibular region for dental implant placement? Is panoramic radiograph safety for dental implant application?
    Bilge, Suheyb
    Demetoglu, Umut
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2021, 12 : S318 - S322