Ray-tracing model of a perfect lens compliant with Fermat's principle: the Cardinal Lens

被引:1
|
作者
Wilde, Jeffrey P. [1 ]
机构
[1] Stanford Univ, EL Ginzton Lab, Stanford, CA 94305 USA
关键词
D O I
10.1364/AO.507605
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
When using ray tracing for optical system design, it is often the case that the designer would like to implement simplified versions of one or more compound lens groups. This could be the case during initial layout when idealized versions of such compound lenses are needed or, perhaps alternatively, to mimic a well -corrected commercially available lens for which the prescription details are unavailable. One option is to use a paraxial thin lens as a proxy for the actual lens group, but doing so will yield a layout that is not consistent with Fermat's principle or the Abbe sine condition. For example, a paraxial lens version of a compound microscope objective typically produces the wrong numerical aperture for a given entrance pupil diameter, and vice versa. A better option is to use a lens model that provides perfect imaging for a specified paraxial magnification and obeys Fermat's principle. A variant of the model can yield a perfect Fourier transform lens. In addition, it is desirable to implement an idealized thick lens in which the principal planes are separated by a user -specified distance. This paper presents such a model, referred to as the Cardinal Lens, with implementation in Zemax OpticStudio via a user -defined surface. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:1110 / 1124
页数:15
相关论文
共 50 条
  • [31] GAUSSIAN THIN LENS AND MIRROR FORMULAS FROM FERMAT PRINCIPLE
    LEMONS, DS
    AMERICAN JOURNAL OF PHYSICS, 1994, 62 (04) : 376 - 378
  • [32] RAY TRACING KINOFORM LENS SURFACES
    SOUTHWELL, WH
    APPLIED OPTICS, 1992, 31 (13): : 2244 - 2247
  • [33] Ray tracing for intraocular lens calculation
    Preussner, PR
    Wahl, J
    Lahdo, H
    Dick, B
    Findl, O
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (08): : 1412 - 1419
  • [34] Effect of a sulcus-fixated piggyback intraocular lens on negative dysphotopsia: Ray-tracing analysis
    Erie, Jay C.
    Simpson, Michael J.
    Bandhauer, Mark H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04): : 443 - 450
  • [35] ACCURATE ELECTRON RAY-TRACING FOR ANALYSIS OF ELECTRON GUNS IMMERSED IN A MAGNETIC-LENS FIELD
    SAITO, K
    UNO, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 363 (1-2): : 48 - 53
  • [36] Ray-tracing through the Millennium Simulation: Born corrections and lens-lens coupling in cosmic shear and galaxy-galaxy lensing
    Hilbert, S.
    Hartlap, J.
    White, S. D. M.
    Schneider, P.
    ASTRONOMY & ASTROPHYSICS, 2009, 499 (01): : 31 - 43
  • [37] 2-POINT RAY TRACING USING FERMAT PRINCIPLE
    WALTHAM, DA
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1987, 89 (01): : 461 - 461
  • [38] Trans-ionospheric Ray Tracing by Means of a Direct Approach to Fermat's Principle
    Coleman, Christopher J.
    2013 7TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2013, : 3660 - 3662
  • [39] 2-POINT RAY TRACING USING FERMAT PRINCIPLE
    WALTHAM, DA
    GEOPHYSICAL JOURNAL-OXFORD, 1988, 93 (03): : 575 - 582
  • [40] A ray-tracing model of the Vela pulsar
    Hirano, C