Solid-phase extraction coupled with LC-MS for the determination of fentanyl analogs in biological samples

被引:0
|
作者
Wang, Lingyan [1 ]
Wang, Wei [1 ]
Yao, Weixuan [2 ]
Hua, Ziluo [3 ]
Zhang, Suling [3 ]
Wang, Jiye [2 ]
Wu, Yuanzhao [2 ]
Wang, Binjie [2 ]
机构
[1] Narcotics Division of Hangzhou Municipal Public Security Bureau, Hangzhou,310053, China
[2] Key Laboratory of Drug Prevention and Control Technology of Zhejiang Province, Department of Criminal Science and Technology, Zhejiang Police College, Hangzhou,310053, China
[3] College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou,310018, China
关键词
Anesthetics - Extraction - Liquid chromatography - Mass spectrometry;
D O I
10.13595/j.cnki.issn1000-0720.2020.101001
中图分类号
学科分类号
摘要
A solid-phase extraction (SPE) coupled with liquid chromatography-mass spectrometry (LC-MS) method was established for the determination of 10 fentanyl analogs in serum and urine samples. The sample solution was extracted by the C18 SPE column. Then, the analytes on SPE column were eluted with methanol. The eluate was collected and determined by LC-MS. For the urine matrix, the linearity range of each fentanyl analog was 1-100 μg / L with R2 higher than 0. 99. The limits of detection (LODs) and limits of quantification (LOQs) were 0. 18-0. 32 μg / L and 0. 61-1. 00 μg / L, respectively. For the serum matrix, the linearity range of each fentanyl analog was 2-100 μg / L with R2 higher than 0. 99. The LODs and LOQs were 0. 15-0. 33 μg / L and 0. 50-1. 00 μg / L, respectively. The extraction recovery rates in urine and serum were 84. 2%-107. 7% and 84. 7%-99. 7%, respectively. No significant matrix effect was observed. This method can satisfy the requirement for simultaneous analysis of various fentanyl analogs in biological samples. © 2021, Youke Publishing Co.,Ltd. All rights reserved.
引用
收藏
页码:885 / 889
相关论文
共 50 条
  • [1] Development and validation of protocols for solid-phase extraction coupled to LC and LC-MS
    Ooms, JAB
    Van Gils, GJM
    Duinkerken, AR
    Halmingh, O
    AMERICAN LABORATORY, 2000, 32 (18) : 52 - +
  • [2] Trimethylsilyldiazomethane derivatization coupled with solid-phase extraction for the determination of alendronate in human plasma by LC-MS/MS
    Chen, Meixia
    Liu, Ke
    Zhong, Dafang
    Chen, Xiaoyan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (02) : 791 - 798
  • [3] Trimethylsilyldiazomethane derivatization coupled with solid-phase extraction for the determination of alendronate in human plasma by LC-MS/MS
    Meixia Chen
    Ke Liu
    Dafang Zhong
    Xiaoyan Chen
    Analytical and Bioanalytical Chemistry, 2012, 402 : 791 - 798
  • [4] Determination of glabridin in human plasma by solid-phase extraction and LC-MS/MS
    Aoki, F
    Nakagawa, K
    Tanaka, A
    Matsuzaki, K
    Arai, N
    Mae, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 70 - 74
  • [5] Determination of selected β-receptor antagonists in biological samples by solid-phase extraction with cholesterolic phase and LC/MS
    Buszewski, Boguslaw
    Welerowicz, Tomasz
    Tegowska, Eugenia
    Krzeminski, Tadeusz F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) : 263 - 272
  • [6] Determination of selected β-receptor antagonists in biological samples by solid-phase extraction with cholesterolic phase and LC/MS
    Bogusław Buszewski
    Tomasz Welerowicz
    Eugenia Tęgowska
    Tadeusz F. Krzemiński
    Analytical and Bioanalytical Chemistry, 2009, 393 : 263 - 272
  • [7] Magnetic solid-phase extraction coupled with LC-MS/MS methods for the simple extraction and rapid determination of sugammadex in human plasma
    Wang, Yanan
    Qu, Yinyin
    Jiang, Yi
    Li, Zhuo
    Hou, Xiaofei
    Yang, Li
    Zhao, Libo
    Xiong, Xin
    Xu, Mao
    ANALYTICAL METHODS, 2024, 16 (40) : 6907 - 6915
  • [8] The determination of patulin from food samples using dual-dummy molecularly imprinted solid-phase extraction coupled with LC-MS/MS
    Zhao, Minjuan
    Shao, Hua
    He, Yahui
    Li, Hui
    Yan, Mengmeng
    Jiang, Zejun
    Wang, Jing
    Abd El-Aty, A. M.
    Hacimuftuoglu, Ahmet
    Yan, Feiyan
    Wang, Yanli
    She, Yongxin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1125
  • [9] Determination of triazine herbicides in fruits and vegetables using dispersive solid-phase extraction coupled with LC-MS
    Ji, Feng
    Zhao, Lixia
    Yan, Wei
    Feng, Qinzhong
    Lin, Jin-Ming
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (6-7) : 961 - 968
  • [10] Determination of bisphenols in food and its contact materials migration by magnetic solid-phase extraction coupled with LC-MS/MS
    Yang, Cheng
    Wang, Yan
    Dong, Pei-Zhi
    Li, Yanan
    Pang, Yue-Hong
    FOOD BIOSCIENCE, 2024, 59