Experimental and numerical study on thermal performance of new envelope and triangular vortex generators with different pitch and angle of attack

被引:3
|
作者
Srivastava, Kartik [1 ]
Sahoo, Rashmi Rekha [1 ]
机构
[1] IIT BHU, Dept Mech Engn, Varanasi 221005, India
关键词
Envelope; Triangular; Vortex generator; TEF Pressure drop CBR; THERMOELECTRIC-HYDRAULIC PERFORMANCE; HEAT-TRANSFER ENHANCEMENT; POWER GENERATOR; FINNED-TUBE; EXCHANGER; OPTIMIZATION; SIMULATION; CHANNEL; CONFIGURATION; AUGMENTATION;
D O I
10.1016/j.tsep.2024.102459
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, experimental work has been carried out to analyze the effect of different Vortex Generators (VGs) shapes (including novel envelope shape geometry), pitch ratios, and angles of attack on various thermohydraulic parameters of the channel, and the performance of the thermoelectric generator (TEG) system. The geometry of VGs introduced in the study are triangular (Delta or D -shape) and envelope (M -shape). Numerical analysis of the temperature, pressure, and velocity distribution has been carried out to understand the effect of the vortex generators. In the study, the channel has been divided into control volumes to observe the variation in the hot gas temperature, heat transfer coefficient, percentage Nusselt number change, pressure drop, thermal enhancement factor (TEF), cost -benefit ratio (CBR), and power output of the TEG system due to the different configurations employed. Triangular VG exhibits the maximum heat transfer coefficient of 342.41 W/m2K at pitch ratio 2 and 60 degrees angle of attack. Also, the highest increment in percentage Nusselt number of 4.2 % is shown by triangular VG (p = 2, theta = 60 degrees). Maximum pressure loss occurs for VGs with theta = 90 degrees for all configurations, out of which the Dshape causes the highest loss due to the largest frontal area. Triangular winglet vortex generators at 45 degrees showed 7.6 %, 6.17 %, and 46.16 % higher thermal enhancement factor (TEF) than at 30 degrees, 60 degrees, and 90 degrees respectively. Hot air at 30 degrees had the lowest cost -benefit ratio. The maximum TEG power output of 1.5 W is observed for D -shape VG at p = 2 and theta = 60 degrees, which is 267.24 % higher than that of the flat geometry channel flow. Therefore, the channel employed with D -shape VG at p = 2 and theta = 60 degrees is settled for the best configuration for the overall parameters studied. The study also suggests using VGs for enhanced performance of a TEG system.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Numerical investigation to predict optimum attack angle combination of longitudinal vortex generators in compact heat exchangers for thermo-hydraulic heightened performance
    Mohd Zeeshan
    Sujit Nath
    Dipankar Bhanja
    Sādhanā, 2019, 44
  • [22] Numerical investigation to predict optimum attack angle combination of longitudinal vortex generators in compact heat exchangers for thermo-hydraulic heightened performance
    Zeeshan, Mohd
    Nath, Sujit
    Bhanja, Dipankar
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2019, 44 (12):
  • [23] Experimental study of asymmetric vortex control at high angle of attack with synthetic jet
    Li, Binbin
    Jiang, Yubiao
    Gu, Yunsong
    Cheng, Keming
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2015, 36 (03): : 764 - 771
  • [24] A numerical and experimental study on the effect of the orifice angle of vortex tube in vortex spinning machine
    Li, Meiling
    Yu, Chongwen
    Shang, Shanshan
    JOURNAL OF THE TEXTILE INSTITUTE, 2013, 104 (12) : 1303 - 1311
  • [25] Experimental and Numerical Investigation on Effect of Convergent Angle and Cold Orifice Diameter on Thermal Performance of Convergent Vortex Tube
    Rafiee, Seyed Ehsan
    Sadeghiazad, M. M.
    Mostafavinia, Nasser
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (04)
  • [26] Effect of Attack Angle of Concave and Convex Winglets Vortex Generators on Thermal-Hydraulic Performance of Fin and Tube Heat Exchangers with Field Synergy Principle
    Syaiful
    Yunianto, Bambang
    Salsabila, Carisya Dara
    Fajar, Berkah T. K.
    Soetanto, Maria F.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (03) : 797 - 809
  • [27] THREE-DIMENSIONAL NUMERICAL STUDY OF THE PERFORMANCE OF THE INTERCOOLER EQUIPPED WITH VORTEX GENERATORS
    Djemel, Hassene
    Ben Salem, Mongi
    Baccar, Mounir
    Mseddi, Mohamed
    HEAT TRANSFER RESEARCH, 2017, 48 (08) : 715 - 740
  • [28] Experimental and numerical study of heat transfer of dimple vortex generators with spherical and teardrop shapes
    Rao, Yu
    Li, Bo
    Feng, Yan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (08): : 1774 - 1779
  • [29] Heat transfer enhancement using different types of vortex generators (VGs): A review on experimental and numerical activities
    Awais, Muhammad
    Bhuiyan, Arafat A.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 : 524 - 545
  • [30] Thermal performance of PCCP panel radiators for different convector dimensions - An experimental and numerical study
    Calisir, Tamer
    Yazar, Hakan O.
    Baskaya, Senol
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 137 : 375 - 387