CHARACTERISTICS OF WIND LOADS ACTING ON TALL BUILDINGS BASED ON THE MEASURED WIND FIELD IN URBAN CENTER

被引:0
|
作者
Han, Zhen [1 ]
Li, Bo [1 ,2 ]
Zhen, Wei [3 ]
Tian, Yu-Ji [1 ,2 ]
Li, Chen [1 ]
机构
[1] School of Civil Engineering, Beijing Jiaotong University, Beijing,100044, China
[2] Beijing’s Key Laboratory of Structural Wind Engineering and Urban Wind Environment, Beijing,100044, China
[3] Beijing Institute of Architectural Design Co.,Ltd., Beijing,100045, China
来源
关键词
Tall buildings;
D O I
10.6052/j.issn.1000-4750.2022.04.0316
中图分类号
学科分类号
摘要
The wind profile is a main factor affecting wind load characteristics of tall buildings. To investigate characteristics of wind loads acting on tall buildings in urban central wind field, the measured wind speed data observed continuously from the Beijing Meteorological Tower during 2013-2017 was selected and the power-law was used to fit the measured wind profile based on the layered structure of the urban boundary layer. Wind loads of super-tall buildings with side ratios D/B=1, 2 and 4 in the measured wind field were obtained by carrying out a pressure test of rigid models in a wind tunnel and the results were compared with B and D wind fields in the code. The researches show that based on the layered structure, the power exponent of the measured wind field fitted by the power-law is 0.35. The mean wind velocity profile is similar to the D wind field, while the turbulence profile is larger than that of the D wind field. Compared with the wind load in B and D wind fields, the measured wind field has less effect on the mean wind load of super-tall buildings but a greater effect on the fluctuating wind load. Moreover, with the increase of the building side ratio, the fluctuating wind effect is enhanced significantly under the measured wind field. There is a strong correlation between the across-wind and torsional moment coefficients at the base, and correlation in the extreme values exists, especially for the building with D/B=4 at 90° wind direction, while two kinds of correlations are both enhanced in the measured wind field. © 2024 Tsinghua University. All rights reserved.
引用
收藏
页码:124 / 134
相关论文
共 50 条
  • [21] COMPARATIVE STUDY OF ALONG-WIND AND ACROSS WIND LOADS ON TALL BUILDINGS WITH DIFFERENT CODES
    Zhang, Zhengwei
    To, Alex
    [J]. Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 723 - 728
  • [22] Study on wind loads and wind-induced responses of rectangular tall buildings with structural joints
    Yuan, Jiahui
    Chen, Shuifu
    Xia, Yuchao
    Liu, Yi
    [J]. Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2024, 55 (07): : 2663 - 2676
  • [23] The effects of grooves on wind characteristics of tall cylinder buildings
    Yuan, Wei-bin
    Yu, Nan-ting
    Wang, Zhao
    [J]. WIND AND STRUCTURES, 2018, 26 (02) : 89 - 98
  • [24] Wind response characteristics for habitability of tall buildings in Japan
    Graduate School of Frontier Science, University of Tokyo, Japan
    不详
    [J]. Struct. Des. Tall Spec. Build., 1600, 3 (683-718):
  • [25] Wind response characteristics for habitability of tall buildings in Japan
    Kim, Y. C.
    Kanda, J.
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2008, 17 (03): : 683 - 718
  • [26] Field measurements of boundary layer wind characteristics and wind-induced responses of super-tall buildings
    Fu, J. Y.
    Li, Q. S.
    Wu, J. R.
    Xiao, Y. Q.
    Song, L. L.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (8-9) : 1332 - 1358
  • [27] Downburst versus boundary layer induced wind loads for tall buildings
    Kim, Jongdae
    Hangan, Horia
    Ho, T. C. Eric
    [J]. WIND AND STRUCTURES, 2007, 10 (05) : 481 - 494
  • [28] WIND LOADS ON TALL STACKS
    VICKERY, BJ
    [J]. BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1968, 49 (07) : 773 - &
  • [29] Structural Improvements for Tall Buildings under Wind Loads: Comparative Study
    Longarini, Nicola
    Cabras, Luigi
    Zucca, Marco
    Chapain, Suvash
    Aly, Aly Mousaad
    [J]. SHOCK AND VIBRATION, 2017, 2017
  • [30] Influence of Cross-Sectional Shapes on Wind Loads on Tall Buildings
    Abdusemed, M. A.
    Ahuja, A. K.
    [J]. Structures Congress 2015, 2015, : 2667 - 2678