Comparison of 3D and 2D laparoscopy: Initial experience of perioperative outcomes and clinical assessment

被引:0
|
作者
Yang, Li [1 ]
Bu, Guosen [2 ]
Zhao, Jing [1 ]
La, Xiaolin [1 ,3 ,4 ,5 ]
Ma, Cailing [6 ]
机构
[1] Xinjiang Med Univ, Affiliated Hosp 1, Ctr Reprod Med, Urumqi 830054, Peoples R China
[2] Xinjiang Med Univ, Affiliated Hosp 1, Internal Med Neurol, Urumqi 830054, Peoples R China
[3] Res Ctr Integrated Prevent & Treatment Reprod Dis, Urumqi 830054, Peoples R China
[4] Xinjiang Med Univ, Affiliated Hosp 1, Xinjiang Clin Res Ctr Reprod Immunol, Urumqi 830054, Peoples R China
[5] Xinjiang Med Univ, State Key Lab Pathogenesis Prevent & Treatment Hig, Urumqi 830054, Peoples R China
[6] Xinjiang Med Univ, Affiliated Hosp 1, Dept Gynaecol, Urumqi 830054, Peoples R China
关键词
Laparoscopy; Three dimension; Cervical cancer; Pelvic lymphadenectomy; RADICAL HYSTERECTOMY; HIGH-DEFINITION; PERFORMANCE; SURGERY; VISION; PROFICIENCY; CANCER; SKILLS;
D O I
10.1016/j.jogoh.2024.102754
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction: This study was designed to compare three-dimensional (3D) laparoscopy and conventional twodimensional (2D) laparoscopy in surgical performance and clinical assessment during laparoscopic radical hysterectomy with pelvic lymphadenectomy (LRHND) for treating early-stage cervical cancer. Material and methods: In this study, we included 67 consecutive patients underwent LRHND for treating earlystage cervical cancer by the experienced laparoscopic surgeons between August 2018 and December 2020. amongst these patients, 32 patients underwent 3D laparoscopy (2D group) and 35 patients underwent 2D laparoscopy (2D group). Demographic data, clinical and surgical parameters were obtained from each patient. An end-of-operation questionnaire was administered regarding subjective perception of 3D laparoscopy system. Results: Patient characteristics, including age, BMI, FIGO stage, and histology, were comparable between the two groups. Compared with 2D imaging system, 3D system significantly shortened the operation time, especially bilateral lymph node dissection time. Blood loss was lower in 3D group compared with 2D group. There were no significant differences regarding pelvic nodes retrieved, incidence of complications, hospital stay, the recovery time of bowel, abdominal drainage fluid, hospitalization costs and visual symptoms. In addition, 3D system significantly improved depth perception and precision, and reduced surgical strain and eye strain for surgeon. No statistical difference was observed in visual symptoms and adverse events between the two groups. The surgeon was more willing to accept 3D laparoscopy. Conclusion: The 3D laparoscopy is safe, feasible and comfortable, with obvious advantage in depth perception, precision and surgical strain. It triggered no increase in the complications and adverse events.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Registration Using Nanotube Stationary Tomosynthesis: Comparison of 3D/3D to 3D/2D Methods
    Frederick, B.
    Lalush, D.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [32] Comparison of 2D versus 3D in the Basic Single Incision Laparoscopy Training. A Randomized Controlled Trial
    Potapov, Oleksii
    Kosiukhno, Sergii
    Kalashnikov, Oleksandr
    Marino, Marco, V
    Todurov, Ivan
    Komorowski, Andrzej L.
    CHIRURGIA, 2022, 117 (01) : 69 - 80
  • [33] Comparison of Manual (2D) and Digital (3D) Methods in the Assessment of Simulated Facial Edema
    Dallazen, Eduardo
    Baccaro, Gabriela Cristina
    Santos, Anderson Maikon de Souza
    Queiroz, Mariana Elias
    Santiago Junior, Joel Ferreira
    Hochuli-Vieira, Eduardo
    Faverani, Leonardo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 81 (09) : 1146 - 1154
  • [34] 2D or not 2D That is the Question, but 3D is the, answer
    Cronin, Paul
    ACADEMIC RADIOLOGY, 2007, 14 (07) : 769 - 771
  • [35] Intracranial 2D and 3D DSA with flat panel detector of the direct conversion type: initial experience
    Yoshihisa Hatakeyama
    Shingo Kakeda
    Yukunori Korogi
    Norihiro Ohnari
    Junji Moriya
    Nobuhiro Oda
    Kazuyoshi Nishino
    Wataru Miyamoto
    European Radiology, 2006, 16 : 2594 - 2602
  • [36] A comparison of 2D and 3D acquisition on an LSO based clinical PET scanner.
    Lodge, MA
    Dibos, PE
    Gilbert, R
    Badawi, RD
    Line, BR
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 282P - 283P
  • [37] Intracranial 2D and 3D DSA with flat panel detector of the direct conversion type: initial experience
    Hatakeyama, Yoshihisa
    Kakeda, Shingo
    Korogi, Yukunori
    Ohnari, Norihiro
    Moriya, Junji
    Oda, Nobuhiro
    Nishino, Kazuyoshi
    Miyamoto, Wataru
    EUROPEAN RADIOLOGY, 2006, 16 (11) : 2594 - 2602
  • [38] User experience and interaction performance in 2D/3D telecollaboration
    Anton, David
    Kurillo, Gregorij
    Bajcsy, Ruzena
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2018, 82 : 77 - 88
  • [39] 3D and 2D/3D holograms model
    A. A. Boriskevich
    V. K. Erohovets
    V. V. Tkachenko
    Optical Memory and Neural Networks, 2012, 21 (4) : 242 - 248
  • [40] Comparison of Therapeutic Effects Between Conventional 2D Laparoscopy and 3D Laparoscopy in the Treatment of Colorectal Cancer: A Systematic Review and Meta-Analysis
    Zhan, Shixiong
    Zhu, Zhicheng
    Yu, Haitao
    Xia, Yu
    Zhu, Yuangui
    Wu, Feixiang
    Liao, Hui
    Wan, Zhenda
    AMERICAN SURGEON, 2024, 90 (11) : 3102 - 3112