Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device

被引:21
|
作者
Lodge, Clare [1 ,3 ]
Tobin, Diarmuid [1 ]
O'Rourke, Brian [1 ]
Thorborg, Kristian [2 ]
机构
[1] Inst Technol Carlow, Dept Sci & Hlth, Carlow, Ireland
[2] Univ Copenhagen, Fac Hlth Sci, Hvidovre, Denmark
[3] Inst Technol Carlow, Dept Sci & Hlth, Kilkenny Rd, Carlow, Ireland
关键词
Clinical decision-making; Hamstring muscles; Rehabilitation; SOCCER PLAYERS; EXERCISE; INJURIES;
D O I
10.1016/j.arrct.2019.100034
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device.Design: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device.Setting: Institute of Technology Carlow, third level educational institution.Participants: Male intercollegiate field-sport players completed the trial (N=19). Participants were 21 +/- 2 years, weighed 78.6 +/- 4.6 kg, and were 179.6 +/- 6.4 cm in height. Interventions: N/A.Main Outcome Measures: Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device.Results: High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)= .910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC% = 14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively.Conclusion(s): The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management.(c) 2019 The Authors. Published by Elsevier Inc. on behalf of the American Congress of Rehabil-itation Medicine. This is an open access article under the CC BY-NC-ND license (http:// creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [21] The reliability of and agreement between devices used to measure eccentric hamstring strength: a systematic review protocol
    Daniel Torpey
    Eoghan Murray
    Tom Hughes
    Jamie Sergeant
    Michael Callaghan
    Systematic Reviews, 11
  • [22] Validity and Reliability of the Achillometer®: An Ankle Dorsiflexion Measurement Device
    Kleeblad, Laura J.
    van Bemmel, Annelies F.
    Sierevelt, Inger N.
    Zuiderbaan, Hendrik A.
    Vergroesen, Diederik A.
    JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (04): : 688 - 692
  • [23] The reliability and validity of a video-based method for assessing hamstring strength in football players
    Lee, Justin W. Y.
    Li, Cheng
    Yung, Patrick S. H.
    Chan, Kai-Ming
    JOURNAL OF EXERCISE SCIENCE & FITNESS, 2017, 15 (01) : 18 - 21
  • [24] HAMSTRING INJURIES IN SPRINTERS - THE ROLE OF CONCENTRIC AND ECCENTRIC HAMSTRING MUSCLE STRENGTH AND FLEXIBILITY
    JONHAGEN, S
    NEMETH, G
    ERIKSSON, E
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (02): : 262 - 266
  • [25] Validity and reliability of Squegg device in measuring isometric handgrip strength
    Bairapareddy, K. C.
    Khaleel, A.
    Akbar, S.
    Maherban, H.
    Mehdiyeva, F.
    Rasti, F.
    Tamim, M.
    Abdelbasset, W. K.
    Ezzat, W.
    Reddy, R. S.
    Tedla, J. S.
    Ramakrshnan, S.
    Hussein, R. S.
    Alaparthi, G. K.
    Elsayed, S. H.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (21) : 10247 - 10254
  • [26] Reliability and Validity of a Novel Wearable Device for Measuring Elbow Strength
    Brookshaw, Marcus
    Sexton, Andrew
    McGibbon, Chris A.
    SENSORS, 2020, 20 (12) : 1 - 16
  • [27] A New Measuring Approach in Assessing Hamstring Flexibility: Reliability, Validity, and Applicability of Isolated Hamstring Flexibility Test
    Talu, Yasin
    Tuncer, Aysenur
    Talu, Burcu
    CLINICAL JOURNAL OF SPORT MEDICINE, 2024, 34 (05): : 430 - 435
  • [28] New Assessment of Forearm Strength: Reliability and Validity
    Wong, Christopher Kevin
    Moskovitz, Neil
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2010, 64 (05): : 809 - 813
  • [29] Validity and Intrarater Reliability of the FysioMeter-Measuring Eccentric Knee Flexor Force During the Nordic Hamstring Exercise
    Stove, Morten Pallisgaard
    Kristensen, Mathias Kringelholt
    Nielsen, Jonas
    Madsen, Lea Dyhrberg
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2025,
  • [30] RELIABILITY AND VALIDITY OF ULTRASONOGRAPHY FOR MEASUREMENT OF HAMSTRING MUSCLE AND TENDON CROSS-SECTIONAL AREA
    Kositsky, Adam
    Goncalves, Basilio A. M.
    Stenroth, Lauri
    Barrett, Rod S.
    Diamond, Laura E.
    Saxby, David J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (01): : 55 - 63