Recent advances in data collection for Cryo-EM methods

被引:5
|
作者
Cheng, Anchi [1 ]
Yu, Yue [1 ]
机构
[1] Zuckerberg Inst Adv Biol Imaging CZ Im Inst, 3400 Bridge Pkwy, Redwood City, CA 94065 USA
关键词
TOMOGRAPHY;
D O I
10.1016/j.sbi.2024.102795
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Methods of transmission electron microscopy (TEM) are typically used to resolve structures of vitrified biological specimens using both single particle analysis (SPA) and tomographic methods and use both conventional as well as scanning transmission modes of data collection. Automation of data collection for each method has been developed to different levels of convenience for the users. Automation of methods using the conventional TEM mode has progressed the furthest. Beam-image shift strategies first used in data collection for SPA were shown to be equally valuable for cryo-electron tomography (cryo-ET). Machine learning methods have been applied for target selection and for planning optimal paths of data collection for SPA. These methods also enabled automated screening. Apertures matching the square shape of cameras have been recently described. Some progress has also been made in the automation of cryo applications of scanning TEM, promising an increase of throughput and potential for further improvement.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Grid preparation and data collection for cryo-EM
    Chang, Leifu
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : A395 - A395
  • [2] Grid preparation and data collection for cryo-EM
    Chang, Leifu
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : A273 - A273
  • [3] Recent algorithmic advances for single-particle cryo-EM
    Punjani, Ali
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : A405 - A405
  • [4] Focus: The interface between data collection and data processing in cryo-EM
    Biyani, Nikhil
    Righetto, Ricardo D.
    McLeod, Robert
    Caujolle-Bert, Daniel
    Castano-Diez, Daniel
    Goldie, Kenneth N.
    Stahlberg, Henning
    JOURNAL OF STRUCTURAL BIOLOGY, 2017, 198 (02) : 124 - 133
  • [5] Overcoming resolution attenuation during tilted cryo-EM data collection
    Aiyer, Sriram
    Baldwin, Philip R.
    Tan, Shi Min
    Shan, Zelin
    Oh, Juntaek
    Mehrani, Atousa
    Bowman, Marianne E.
    Louie, Gordon
    Passos, Dario Oliveira
    Dordevic-Marquardt, Selena
    Mietzsch, Mario
    Hull, Joshua A.
    Hoshika, Shuichi
    Barad, Benjamin A.
    Grotjahn, Danielle A.
    Mckenna, Robert
    Agbandje-McKenna, Mavis
    Benner, Steven A.
    Noel, Joseph A. P.
    Wang, Dong
    Tan, Yong Zi
    Lyumkis, Dmitry
    NATURE COMMUNICATIONS, 2024, 15 (01)
  • [6] Best Practices in Data Collection and DDD Movie Processing for Cryo-EM
    Rubinstein, John
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 341A - 341A
  • [7] Overcoming resolution attenuation during tilted cryo-EM data collection
    Sriram Aiyer
    Philip R. Baldwin
    Shi Min Tan
    Zelin Shan
    Juntaek Oh
    Atousa Mehrani
    Marianne E. Bowman
    Gordon Louie
    Dario Oliveira Passos
    Selena Đorđević-Marquardt
    Mario Mietzsch
    Joshua A. Hull
    Shuichi Hoshika
    Benjamin A. Barad
    Danielle A. Grotjahn
    Robert McKenna
    Mavis Agbandje-McKenna
    Steven A. Benner
    Joseph A. P. Noel
    Dong Wang
    Yong Zi Tan
    Dmitry Lyumkis
    Nature Communications, 15
  • [8] CryoRL: Reinforcement Learning Enables Efficient Cryo-EM Data Collection
    Cianfrocco, Michael
    Li, Yilai
    Fan, Quanfu
    Cohn, John
    Vas, Seychelle
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2022, 78 : A171 - A171
  • [9] Methods to account for movement and flexibility in cryo-EM data processing
    Rawson, S.
    Iadanza, M. G.
    Ranson, N. A.
    Muench, S. P.
    METHODS, 2016, 100 : 35 - 41
  • [10] Recent Advances and Best Practices for Cryo-EM Analysis for Protein Structure Determination
    Bergeron, Julien
    Rapisarda, Chiara
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (192):