Survivorship of anatomic press-fit short-stem radial head replacement with a pyrocarbon bearing

被引:2
|
作者
Viswanath, Aparna I. [1 ]
Watts, Adam C. [1 ]
机构
[1] Wrightington Hosp, Dept Orthopaed, Upper Limb Unit, Wrightington, Lancs, England
关键词
Fracture; radial head; radial head arthroplasty; elbow fracture-dislocation; pyrocarbon; press-fit; ARTHROPLASTY; FRACTURES; PROSTHESIS; MIDTERM; REVISION; OUTCOMES;
D O I
10.1177/17585732211024182
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Restoring the radial head as a stabiliser of the elbow is considered important in cases where there is an associated bony or ligamentous injury. A variety of radial head prostheses are available. There are no reports of the survivorship of a short-stem press-fit radial head prostheses with pyrocarbon bearing. Patients and methods With institutional review board approval, a retrospective case-note analysis was performed of a consecutive single-surgeon case series of the Integra LifeScience pyrocarbon radial head prostheses (Carbon Modular Radial Head) from October 2010 to October 2019 in a tertiary referral centre. The series was divided into acute trauma and salvage cohorts. Kaplan-Meier survivorship analysis was conducted. Results 36 patients were included, 23 (64%) for acute injuries and 13 (36%) for failed initial treatment. Of the acute injuries, 20 (87%) had a Wrightington type-C elbow fracture-dislocation. Reoperation was performed in 4 (11%) patients; 10 (28%) had possible loosening on radiographs. The implant survival rate was 94% at shortest follow-up of 17 months (mean 70 months). Discussion Treatment of complex radial head fractures using a pyrocarbon-bearing, anatomic press-fit design provides satisfactory short-term survivorship in this case series. The implant should be used with caution in salvage cases, due to higher rates of loosening seen in this cohort.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 28 条
  • [21] Radiographic changes differ between two different short press-fit humeral stem designs in total shoulder arthroplasty
    Denard, Patrick J.
    Noyes, Matthew P.
    Walker, J. Brock
    Shishani, Yousef
    Gobezie, Reuben
    Romeo, Anthony A.
    Lederman, Evan
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) : 217 - 223
  • [22] Response to La Banca et al regarding "On the concerning early failure of a short stem press-fit humeral component"
    Nicholson, Gregory
    Pourzal, Robin
    Garrigues, Grant E.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (03) : e178 - e178
  • [23] Ex vivo postimplantation biomechanical properties of a press-fit cementless femoral stem with transfixation pin for canine total hip replacement
    Saban, Charles
    Roels, Josephine
    Deprey, Julie
    Massenzio, Michel
    Viguier, Eric
    Cachon, Thibaut
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2022, 83 (11)
  • [24] Radial Neck Dilatory Remodeling After Radial Head Arthroplasty With an Uncemented, Press Fit, Fully Chemically Etched Stem Design
    Sullivan, Matthew P.
    Firoozabadi, Reza
    Kennedy, Stephen A.
    Agel, Julie
    Magnusson, Eric
    Schiffman, Brett
    Folchert, Matthew
    Beingessner, Daphne
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (09) : 497 - 502
  • [25] Loose-fit vs. press-fit stems and risk for surgical reintervention following radial head arthroplasty: a US-based cohort study of 1575 patients
    Zeltser, David W.
    Royse, Kathryn E.
    Prentice, Heather A.
    Reyes, Chelsea
    Paxton, Elizabeth W.
    Navarro, Ronald A.
    Foroohar, Abtin
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (02) : 516 - 524
  • [26] Stress Shielding around Press-Fit Radial Head Arthroplasty: Proposal for a New Classification System Based on the Analysis of 97 Patients with a Mid-Term Follow-Up and a Review of the Literature
    Giannicola, Giuseppe
    Amura, Andrea
    Prigent, Sebastien
    Zoccali, Carmine
    Sessa, Pasquale
    HEALTHCARE, 2024, 12 (03)
  • [27] Ultra-Short Anatomic Uncemented Femoral Stem and Ceramic-on-Ceramic Bearing in Patients With Idiopathic or Ethanol-Induced Femoral Head Osteonecrosis
    Kim, Young-Hoo
    Park, Jang-Won
    JOURNAL OF ARTHROPLASTY, 2020, 35 (01): : 212 - 218
  • [28] Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis
    Klaassen, Amanda D.
    van Loon, Justin
    Willigenburg, Nienke W.
    Koster, Lennard A.
    Kaptein, Bart L.
    Van der Hulst, Victor P. M.
    Haverkamp, Daniel
    Moojen, Dirk Jan F.
    Poolman, Rudolf W.
    HIP INTERNATIONAL, 2024, 34 (06) : 701 - 716