On the Measurement of Electron Temperature of a Pulsed Washer Gun Argon Plasma by Triple Langmuir Probe Diagnostic Technique

被引:0
|
作者
Sethy, B. K. [1 ]
Paikaray, R. [1 ]
Das, P. [1 ]
Samantaray, S. [2 ]
Sasini, N. C. [3 ]
Mohanty, B. [4 ]
Sahoo, G. [5 ]
Sanyasi, A. K. [6 ]
Ghosh, J. [6 ]
机构
[1] Ravenshaw Univ, Dept Phys, Cuttack 753003, Odisha, India
[2] Christ Coll, Dept Phys, Cuttack 753008, Odisha, India
[3] Dept Phys, GC Coll, Jajpur 755003, Odisha, India
[4] Dept Math & Sci, Skill Dev & Tech Educ, Jajpur 755019, Odisha, India
[5] Cent Univ Himachal Pradesh, Dept Phys & Astron Sci, Shahpur Parishar 176206, Himachal Prades, India
[6] Inst Plasma Res, Gandhinagar 382428, Gujarat, India
来源
关键词
Electron temperature; Low pressure plasma; Pulsed plasma; Triple probe; Washer gun; DIRECT-DISPLAY; SYSTEM; PARAMETERS;
D O I
10.56042/jsir.v83i4.2407
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pulsed argon plasma of the order of 140 mu s duration is produced by a washer gun under low pressure conditions. The low pressure plasmas have many industrial applications such as etching, coating for corrosion, diamond and diamond like carbon coating, super hard nano composite coating, synthesis of novel nanostructure etc. Measurement of fundamental parameters like electron temperature of such pulsed plasmas is always challenging and should be determined properly. Triple probe diagnostic is the most advanced, convenient and inexpensive method for measurement of plasma temperature which does not require any voltage, frequency sweeps, or switching like single or double probe diagnostic methods. In this work we have introduced a triple Langmuir probe to measure the electron temperature of pulsed washer gun argon plasma. A triple probe of pure tungsten material with appropriate circuit is designed and fabricated in our laboratory. The triple probe signal is recorded by a digital storage oscilloscope at the distance of 0.05 m from the gun mouth. It is observed that the electron temperature remains constant at similar to 1.2 eV within the small variation of base pressure ranging from 0.2 to 1.0 mbar. This method is applicable to both stationary and transient plasma which can be used for various industrial as well as research purpose.
引用
收藏
页码:375 / 380
页数:6
相关论文
共 50 条
  • [21] The Langmuir probe as a diagnostic of the electron component within low temperature laser ablated plasma plumes
    Weaver, I
    Martin, GW
    Graham, WG
    Morrow, T
    Lewis, CLS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1801 - 1805
  • [22] Langmuir probe measurement of plasma splitting during pulsed laser deposition
    Wild, J
    Kudrna, P
    Gronych, T
    Broz, J
    Zelinger, Z
    Kubát, P
    Civis, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (02): : 1597 - 1599
  • [23] PULSED LANGMUIR PROBE MEASUREMENT OF IONIZATION IN A HIGH-PRESSURE PLASMA
    CLEMENTS, RM
    SMY, PR
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1970, IM19 (03) : 167 - +
  • [24] SPHERICAL PULSED LANGMUIR PROBE MEASUREMENT OF IONIZATION IN A HIGH PRESSURE PLASMA
    CLEMENTS, RM
    SMY, PR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (06): : 816 - &
  • [25] Development of a Radiofrequency Plasma Diagnostic System with a Langmuir Probe, and Study of a Capacitively Coupled Argon Plasma
    Mendil, Djelloul
    Lahmar, Hadj
    Ouadjaout, Djamel
    Henni, Laid
    Boufendi, Laifa
    Louhibi, Djelloul
    Henda, Karim
    LASER AND PLASMA APPLICATIONS IN MATERIALS SCIENCE, 2011, 227 : 204 - 207
  • [26] Langmuir probe measurement of the electron temperature in the plasma plume formed by pulsed laser deposition of Bi-Sr-Ca-Cu-O
    Wild, J
    Kudrna, P
    Gronych, T
    Jirsák, T
    Kubát, P
    Zelinger, Z
    Civis, S
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2003, 53 (02) : 171 - 177
  • [27] Langmuir Probe Technique for Plasma Characterization during Pulsed Laser Deposition Process
    Irimiciuc, Stefan Andrei
    Chertopalov, Sergii
    Lancok, Jan
    Craciun, Valentin
    COATINGS, 2021, 11 (07)
  • [28] LANGMUIR PROBE TECHNIQUE FOR PLASMA PARAMETER MEASUREMENT IN A MEDIUM DENSITY DISCHARGE
    HOPKINS, MB
    GRAHAM, WG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (09): : 2210 - 2217
  • [29] LASER OBSORPTION MEASUREMENT OF ELECTRON TEMPERATURE IN AN ARGON PLASMA
    WEISBACH, MF
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1971, 11 (08): : 1225 - &
  • [30] LANGMUIR PROBE MEASUREMENT OF ELECTRON-TEMPERATURE IN A SUPERSONIC JET EXTRACTED FROM AN INDUCTIVELY COUPLED PLASMA
    LIM, HB
    HOUK, RS
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (4-5) : 453 - 461