One-Dimensional orthorhombic CsPbI3 polycrystalline thick film for efficient and highly stable direct X-ray detection and imaging

被引:2
|
作者
Wang, Xinyu [1 ]
Li, Hongkun [1 ]
Xue, Zhiyu [1 ]
Xiang, Yong [1 ,5 ]
Hu, Xiaoran [1 ]
Li, Zhenlin [3 ]
Qin, Haiqing [4 ]
Qin, Aimiao [2 ]
Zhang, Hetong [6 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mat & Energy, Chengdu, Peoples R China
[2] Guilin Univ Technol, Key Lab New Proc Technol Nonferrous Met & Mat, Guangxi Key Lab Opt & Elect Mat & Devices, Minist Educ, Guilin, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Peoples R China
[4] China Nonferrous Met Guilin Geol & Min Co Ltd, Guangxi Key Lab Superhard Mat, Natl Engn Res Ctr Special Mineral Mat, Guilin, Peoples R China
[5] Tianfu Jiangxi Lab, Chengdu, Peoples R China
[6] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester, England
关键词
X-ray detector; Orthorhombic CsPbI 3; Polycrystalline thick film; Liquid epitaxy; AMORPHOUS SELENIUM;
D O I
10.1016/j.cej.2024.150394
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An ideal direct X-ray detector should convert a low dose of X-ray photons into large quantity of electrical signals, coupled with sustained long-term stability. Nevertheless, a notable conflict arises between X-ray absorption efficiency and carrier transport in thick polycrystalline perovskite films. Moreover, conventional perovskite materials exhibit inherent challenges regarding the stability of their crystal phase and the consistency of the photocurrent. To circumvent these limitations, a polycrystalline perovskite thick film is proposed using orthorhombic CsPbI3 (delta-CsPbI3) as a highly stable active material. Combined with the liquid epitaxy process, delta-CsPbI3 prefers one-dimensional growth along the carrier transportation direction, which suppresses the formation of grain boundaries, enabling high carrier mobility while maintaining X-ray absorption for a thick polycrystalline film. Consequently, the polycrystalline delta-CsPbI3 based detector exhibits a highest sensitivity of 1768.46 mu C Gyair -1 cm-2 at an electric field of 432 V mm-1 which is 88.42-fold higher than alpha-Se based detectors and 190-fold higher than the single crystalline delta-CsPbI3 based detector, respectively. The sensitivity maintains 91.34 % of its initial state after 7 days exposure in the air. Combing with a thin-film transistor array, the detector achieves 8-bit imaging within a 64 x 64 matrix. This work provides a feasible method for commercialized production of high-performance direct X-ray detectors.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Highly stable bismuth-chloride perovskite X-ray direct detectors with an ultralow detection limit
    Chen, Haoyu
    Han, Qingyun
    Qin, Haoming
    Shen, Yueqi
    Lv, Huijun
    Liu, Yan
    Du, Liping
    Wang, Yong
    He, Yihui
    Ning, Weihua
    CHEMICAL SCIENCE, 2025, 16 (11) : 4768 - 4774
  • [32] One-dimensional time resolved soft x-ray imaging of colliding plasmas in a laser heated cavity
    Eagleton, RT
    Foster, JM
    Rosen, PA
    Graham, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 834 - 837
  • [33] One-Dimensional All-Inorganic K2CuBr3 with Violet Emission as Efficient X-ray Scintillators
    Gao, Wanru
    Niu, Guangda
    Yin, Lixiao
    Yang, Bo
    Yuan, Jun-Hui
    Zhang, Dongdong
    Xue, Kan-Hao
    Miao, Xiangshui
    Hu, Qingsong
    Du, Xinyuan
    Tang, Jiang
    ACS APPLIED ELECTRONIC MATERIALS, 2020, 2 (07) : 2242 - 2249
  • [34] VANADIUM PENTOXIDE GELS .3. X-RAY AND NEUTRON-DIFFRACTION STUDY OF HIGHLY CONCENTRATED SYSTEMS - ONE-DIMENSIONAL SWELLING
    ALDEBERT, P
    HAESSLIN, HW
    BAFFIER, N
    LIVAGE, J
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1984, 98 (02) : 478 - 483
  • [35] Single-crystal and synchrotron X-ray powder diffraction study of the one-dimensional orthorhombic polymer phase of C60
    Papoular, R. J.
    Toby, B. H.
    Davydov, V. A.
    Rakhmanina, A. V.
    Dzyabchenko, A.
    Allouchi, H.
    Agafonov, V.
    CHEMICAL PHYSICS LETTERS, 2008, 460 (1-3) : 93 - 99
  • [36] Fast one-dimensional wave-front propagation for x-ray differential phase-contrast imaging
    Wolf, Johannes
    Malecki, Andreas
    Sperl, Jonathan
    Chabior, Michael
    Schuettler, Markus
    Beque, Dirk
    Cozzini, Cristina
    Pfeiffer, Franz
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (10): : 3739 - 3747
  • [37] Simultaneous high-resolution two-dimensional spatial and one-dimensional picosecond streaked x-ray pinhole imaging
    Steel, A. B.
    Nagel, S. R.
    Dunn, J.
    Baldis, H. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [38] X-ray Computed Tomography Imaging of the Microstructure of Sand Particles Subjected to High Pressure One-Dimensional Compression
    al Mahbub, Asheque
    Haque, Asadul
    MATERIALS, 2016, 9 (11):
  • [39] Electrospray prepared flexible CsPbBr3 perovskite film for efficient X-ray detection
    Chen, Sixin
    Liu, Weiwei
    Xu, Meng
    Shi, Pan
    Zhu, Menghua
    JOURNAL OF MATERIALS CHEMISTRY C, 2023, 11 (25) : 8431 - 8437
  • [40] One-Dimensional CsCu2I3 Single-Crystal X-ray Detectors
    Wang, Baiqian
    Yang, Xin
    Li, Ru
    Qaid, Saif M. H.
    Cai, Wensi
    Xiao, Hongbin
    Zang, Zhigang
    ACS ENERGY LETTERS, 2023, 8 (10) : 4406 - 4413