MRI Measurements of the Cartilage Contact Pattern, Contact Area, and Contact Centroid of the Glenohumeral Joint During Abduction Under Static Conditions In Vivo

被引:0
|
作者
Shimawaki, Satoshi [1 ]
Tsuchiya, Takuma [2 ]
Suzuki, Misato [2 ]
Toishi, Mitsuru [3 ]
Mori, Harushi [4 ]
机构
[1] Utsunomiya Univ, Dept Fundamental Engn, Mech Syst Engn Course, Tochigi 3218585, Japan
[2] Utsunomiya Univ, Grad Sch Reg Dev & Creat, Grad Program Mech & Intelligent Engn, Div Engn & Agr, Tochigi 3218585, Japan
[3] Jichi Med Univ Hosp, Cent Radiol Div, Tochigi 3290498, Japan
[4] Jichi Med Univ, Dept Radiol, Tochigi 3290498, Japan
关键词
Biomechanics; Glenohumeral joint; Cartilage contact pattern; Abduction; In vivo measurement; ROTATOR CUFF TEARS; NEGATIVE INTRAARTICULAR PRESSURE; SHOULDER KINEMATICS; PASSIVE STABILITY; MUSCLE-ACTIVITY; TRANSLATION; IMPINGEMENT; HEALTHY; ADDUCTOR; POSITION;
D O I
10.1007/s40846-024-00866-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThis study aimed to determine the changes in the cartilage contact pattern, contact area, and contact centroid between the humeral head and glenoid during abduction using magnetic resonance imaging (MRI) under static conditions in vivo. We hypothesized that as the glenohumeral abduction angle increases, the cartilage contact area increases and the contact pattern and contact centroid shift superiorly and anteriorly. MethodsThe present study comprised 14 Japanese men with no history of shoulder injury or disorders. MRI was performed in the following four postures: neutral posture with arms at the side of the trunk and postures at 30 degrees, 60 degrees, and 120 degrees of thoracohumeral abduction, which corresponded to 18.6 degrees +/- 5.7 degrees, 27.8 degrees +/- 7.0 degrees, and 66.8 degrees +/- 13.1 degrees of glenohumeral abduction, respectively. The cartilage contact pattern was determined from the signal intensity profiles of MR images using image analysis software. ResultsWe observed that the contact area was independent of the thoracohumeral abduction angle. The contact area at 120 degrees of thoracohumeral abduction was approximately 10% smaller than at other angles, although this difference was not statistically significant. The contact centroid was significantly shifted superiorly as the thoracohumeral abduction angle increased (p < 0.01), with a trend toward anterior movement. ConclusionThese results confirmed that the contact pattern and contact centroid shifted superiorly and anteriorly. We believe that determining the contact pattern and contact area of the glenohumeral joint is useful for detecting abnormal shoulder joint movements and can guide the diagnosis, treatment, and rehabilitation of patients with shoulder disorders.
引用
收藏
页码:220 / 230
页数:11
相关论文
共 50 条
  • [41] In vivo assessment of patellofemoral joint contact area in individuals who are pain free
    Salsich, GB
    Ward, SR
    Terk, MR
    Powers, CM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) : 277 - 284
  • [42] INFLUENCE OF EXTERNAL LOADS UPON AREA OF CONTACT IN TALO-NAVICULAR JOINT UNDER EXPERIMENTAL CONDITIONS
    ZITZLSPERGER, S
    BECKER, CM
    ANATOMICAL RECORD, 1964, 148 (02): : 412 - &
  • [43] In Vivo Changes in Contact Regions of the Radiocarpal Joint During Wrist Hyperextension
    Tang, Jin Bo
    Chen, Yan Rong
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (11): : 2257 - 2262
  • [44] EFFECT OF JOINT CENTER LOCATION ON IN-VIVO JOINT CONTACT FORCES DURING WALKING
    Kim, Yoon-Hyuk
    Park, Won-Man
    Bui Thi Thanh Phuong
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 267 - 268
  • [45] MRI study of rat cartilage ageing process: knee joint contact sites geometrical assessments
    Pouletaut, P.
    Goebel, J. C.
    Pinzano, A.
    Bolbos, R.
    Beuf, O.
    Netter, P.
    Tho, M. C. Ho Ba
    Gillet, P.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 : 183 - 184
  • [46] Influence of Friction Interface Contact on Ultrasonic Motor Efficiency Under Static Conditions
    张毅锋
    张武
    肖爱武
    朱萌
    潘云华
    张小亚
    Transactions of Nanjing University of Aeronautics and Astronautics, 2015, 32 (02) : 163 - 173
  • [47] In vivo cartilage contact deformation of human ankle joints under full body weight
    Wan, Lu
    de Asia, Richard J.
    Rubash, Harry E.
    Li, Guoan
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (08) : 1081 - 1089
  • [48] LAYOUT OPTIMIZATION OF A MULTIPLE PINNED JOINT UNDER BENDING IN A LIMITED CONTACT AREA
    Hejazi, Amir Mohsen
    Mohammad, Mohammad Pourgol
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 12, 2014,
  • [49] INCONGRUITY OF 1ST METATARSOPHALANGEAL JOINT - EFFECT ON CARTILAGE CONTACT SURFACE-AREA
    MILLER, F
    ARENSON, D
    WEIL, LS
    JOURNAL OF THE AMERICAN PODIATRY ASSOCIATION, 1977, 67 (05): : 328 - 333
  • [50] Quantification of the changes in contact surface of rat cartilage using MRI during ageing process
    Pouletaut, P.
    Goebel, J-C.
    Pinzano, A.
    Tho, M-C. Ho Ba
    Gillet, P.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 : 105 - 106