Multi-stage humidification-dehumidification system integrated with a crystallizer for zero liquid discharge of desalination brine

被引:1
|
作者
Shamet, Osman [1 ]
Lawal, Dahiru U. [1 ,2 ]
Alawad, Suhaib M. [3 ]
Antar, Mohamed [1 ,2 ]
Zubair, Syed M. [1 ,3 ]
Mansir, Ibrahim B. [4 ,5 ]
Aljundi, Isam H. [2 ,6 ]
机构
[1] King Fahd Univ Petr & Minerals, Mech Engn Dept, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Sustainable Energy Syst, Dhahran 31261, Saudi Arabia
[4] Prince Sattam bin Abdulaziz Univ, Coll Engn Al Kharj, Dept Mech Engn, Al Kharj 11942, Saudi Arabia
[5] Ahmadu Bello Univ, Ctr Energy Res & Training, PMB 1045, Zaria, Nigeria
[6] King Fahd Univ Petr & Minerals, Dept Chem Engn, Dhahran 31261, Saudi Arabia
关键词
Multi-Humidification-Dehumidification (MHDH); Crystallizer; ZLD; Energy analysis; Water access; Economic analysis; Desalination; MEMBRANE DISTILLATION; WATER; DESIGN; COST; RO;
D O I
10.1016/j.enconman.2024.118340
中图分类号
O414.1 [热力学];
学科分类号
摘要
Desalination plants discharge a massive volume of brine every day, which negatively affects the ecosystem, particularly the subsurface ecology and marine life. To mitigate the brines' detrimental effects on the environment and facilitate the recovery of salt crystals and freshwater, the Zero Liquid Discharge (ZLD) approach was proposed. This study proposes four different configurations of multistage humidification dehumidification systems integrated with a crystallizer, exploring their energy and economic implications. Key findings from the study include the higher Gained Output Ratio (GOR) in series configurations due to lower temperature differences, resulting in lower heater energy consumption. The crystallizer significantly enhances water productivity, but it is a major consumer of both electricity (85%) and thermal energy (50.45-57.7%) in the system. Increasing the heat source temperature reduces the Specific Electrical Energy Consumption (SEEC) and the specific area while slightly increasing the Specific Thermal Energy Consumption (STEC). Elevated cooling water temperature raises SEEC and specific area but has negligible effects on STEC. Higher feed water flow rates increase SEEC but lower both STEC and specific area. Feed salinity elevation decreases productivity, SEEC, STEC, and specific area. The crystallizer constitutes 15.43-26.44% of the total capital cost, with series configurations incurring higher costs. Unit freshwater production costs, considering salt selling, range from 1.733 to 4.821 $.m-3. In a waste heat scenario, parallel configurations become profitable, where freshwater can be distributed at zero cost, while the produced salt crystals can be sold at an even lower price of $58.09 per tonne and $57.04 per tonne, respectively.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] STUDYING THE POTENTIAL OF DEPLOYING INTEGRATED HUMIDIFICATION-DEHUMIDIFICATION DESALINATION SYSTEM WITH SOLAR THERMAL SYSTEM
    Abedi, Mahyar
    Saha, Parnab
    Tan, Xu
    Klausner, James F.
    Benard, Andre
    [J]. 8TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, 2023, : 629 - 640
  • [22] Anti-fouling rotating polymer-based heat exchanger for zero liquid discharge humidification-dehumidification desalination
    Ghosh, Durga Prasad
    Hassan, Muawia
    Dennis, Sandra Jean
    Sharma, Deepak
    Elhashimi-Khalifa, Mohammed A.
    Abbasi, Bahman
    [J]. WATER RESEARCH, 2024, 258
  • [23] Performance of a two-stage multi-effect desalination system based on humidification-dehumidification process
    Kang, Huifang
    Yang, Yingjun
    Chang, Zehui
    Zheng, Hongfei
    Duan, Zhanchun
    [J]. DESALINATION, 2014, 344 : 339 - 349
  • [24] Performance limits of zero and single extraction humidification-dehumidification desalination systems
    McGovern, Ronan K.
    Thiel, Gregory P.
    Narayan, G. Prakash
    Zubair, Syed M.
    Lienhard, John H.
    [J]. APPLIED ENERGY, 2013, 102 : 1081 - 1090
  • [25] A novel process of humidification-dehumidification with brine recirculation for desalination in remote areas of the world
    Capocelli, Mauro
    Di Paola, Luisa
    De Falco, Marcello
    Piemonte, Vincenzo
    Barba, Diego
    [J]. DESALINATION AND WATER TREATMENT, 2017, 69 : 244 - 251
  • [27] Performance of a 3-stage regenerative desalination system based on humidification-dehumidification process
    Kang, Huifang
    Luo, Weining
    Zheng, Hongfei
    Yu, Zhiyi
    Cheng, Peng
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 182 - 192
  • [28] CFD Simulation of Dehumidification of Air in Humidification-Dehumidification based Water Desalination System
    Patel, Vatsal
    Patel, Rajesh
    Trapasia, Nidhi
    Patel, Vivek
    [J]. IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2022, 46 (02) : 449 - 463
  • [29] CFD Simulation of Dehumidification of Air in Humidification-Dehumidification based Water Desalination System
    Vatsal Patel
    Rajesh Patel
    Nidhi Trapasia
    Vivek Patel
    [J]. Iranian Journal of Science and Technology, Transactions of Mechanical Engineering, 2022, 46 : 449 - 463
  • [30] Development of an active solar humidification-dehumidification (HDH) desalination system integrated with geothermal energy
    Elminshawy, Nabil A. S.
    Siddiqui, Farooq R.
    Addas, Mohammad F.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 608 - 621