Performance of the Large Field of View Airborne Infrared Scanner and its application potential in land surface temperature retrieval

被引:0
|
作者
Chao WANG [1 ,2 ]
Zhiyuan LI [1 ,2 ]
Xiong XU [1 ,2 ,3 ]
Xiangsui ZENG [1 ,2 ]
Jia LI [1 ,2 ]
Huan XIE [1 ,2 ]
Yanmin JIN [1 ,2 ]
Xiaohua TONG [1 ,2 ]
机构
[1] College of Surveying and Geo-informatics,Tongji University
[2] Shanghai Key Laboratory for Planetary Mapping and Remote Sensing for Deep Space Exploration,Tongji University
[3] Frontiers Science Center for Intelligent Autonomous Systems,Tongji
关键词
D O I
暂无
中图分类号
P407.6 [红外大气遥感];
学科分类号
摘要
The Large Field of View Airborne Infrared Scanner is a newly developed multi-spectral instrument that collects images from the near-infrared to long-wave infrared channels.Its data can be used for land surface temperature (LST) retrieval and environmental monitoring.Before data application,quality assessment is an essential procedure for a new instrument.In this paper,based on the data collected by the scanner near the Yellow River in Henan Province,the geometric and radiometric qualities of the images are first evaluated.The absolute geolocation accuracy of the ten bands of the scanner is approximately 5.1 m.The ground sampling distance is found to be varied with the whisk angles of the scanner and the spatial resolution of the images.The band-to-band registration accuracy between band one and the other nine bands is approximately 0.25 m.The length and angle deformations of the ten bands are approximately 0.67% and 0.3°,respectively.The signal-to-noise ratio (SNR) and relative radiometric calibration accuracy of bands 4,9,and 10 are relatively better than those of the other bands.Secondly,the radiative transfer equation (RTE) method is used to retrieve the LST from the data of the scanner.Measurements of in situ samples are collected to evaluate the retrieved LST.Neglecting the samples with unreasonable retrieved LST,the bias and RMSE between in situ LST measured by CE312 radiometer and retrieved LST are-0.22 K and 0.94 K,and the bias and RMSE are0.27 K and 1.59 K for the InfReC R500-D thermal imager,respectively.Overall,the images of the Large Field of View Airborne Infrared Scanner yield a relatively satisfactory accuracy for both LST retrieval and geometric and radiometric qualities.
引用
收藏
页码:378 / 390
页数:13
相关论文
共 50 条
  • [41] Land Surface Temperature Retrieval Based on Thermal Infrared Channel Decomposed Split-Window Algorithm
    Ye, Xin
    Ren, Huazhong
    Zhu, Jinshun
    Zeng, Hui
    Wang, Baozhen
    Huang, He
    Fan, Wenjie
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2022, 15 : 4971 - 4979
  • [42] Land Surface Temperature Retrieval by LANDSAT 8 Thermal Band: Applications of Laboratory and Field Measurements
    Kafer, Pamela Suelen
    Alves Rolim, Silvia Beatriz
    Iglesias, Maria Lujan
    da Rocha, Najila Souza
    Diaz, Lucas Ribeiro
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2019, 12 (07) : 2332 - 2341
  • [43] Land Surface Temperature Retrieval From Landsat 8 Thermal Infrared Data Over Urban Areas Considering Geometry Effect: Method and Application
    Ru, Chen
    Duan, Si-Bo
    Jiang, Xiao-Guang
    Li, Zhao-Liang
    Jiang, Yazhen
    Ren, Huazhong
    Leng, Pei
    Gao, Maofang
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [44] Algorithm Development for Land Surface Temperature Retrieval: Application to Chinese Gaofen-5 Data
    Chen, Yuanyuan
    Duan, Si-Bo
    Ren, Huazhong
    Labed, Jelila
    Li, Zhao-Liang
    REMOTE SENSING, 2017, 9 (02):
  • [45] Performance evaluation of a large axial field-of-view PET scanner: SET- 2400W
    Fujiwara T.
    Watanuki S.
    Yamamoto S.
    Miyake M.
    Seo S.
    Itoh M.
    Ishii K.
    Orihara H.
    Fukuda H.
    Satoh T.
    Kitamura K.
    Tanaka K.
    Takahashi S.
    Annals of Nuclear Medicine, 1997, 11 (4) : 307 - 313
  • [46] Performance evaluation of a new high-resolution large field-of-view digital PET/CT scanner
    Archibald, Zane
    Stolk, Sophie
    Butterfield, Regan
    Covington, Matthew
    Yap, Jeffrey
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [47] Airborne Image Velocimetry System and Its Application on River Surface Flow Field Measurement
    Cao L.
    Detert M.
    Li D.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2020, 28 (06): : 1271 - 1280
  • [48] A modified land surface temperature split window retrieval algorithm and its applications over China
    Yang, Hu
    Yang, Zhongdong
    GLOBAL AND PLANETARY CHANGE, 2006, 52 (1-4) : 207 - 215
  • [49] The Effect of Fabrication Error on the Performance of Mid-Infrared Metalens with Large Field-of-View
    Li, Aoling
    Li, Jianhua
    Jia, Honghui
    Duan, Huigao
    Hu, Yueqiang
    NANOMATERIALS, 2023, 13 (03)
  • [50] Land Surface Temperature Retrieval Method Based on UAV Thermal Infrared Remote Sensing and Synchronized Atmospheric Profiles
    Ji M.
    Xu Y.
    Mo Y.
    Zhang Y.
    Zhou R.
    Zhu S.
    Journal of Geo-Information Science, 2023, 25 (12) : 2456 - 2467