Simultaneous measurement of temperature and liquid refractive index based on fiber open Fabry-Pérot cavity and Bragg grating

被引:0
|
作者
LIU Qinpeng
WANG Danyang
LI Xingrui
GAO Hong
YU Dakuang
机构
[1] CollegeofScience,Xi'anShiyouUniversity
关键词
D O I
暂无
中图分类号
TP212 [发送器(变换器)、传感器];
学科分类号
080202 ;
摘要
A temperature and refractive index sensor based on fiber Bragg grating(FBG) end surface cascade open Fabry-Pérot(FP) cavity has been designed and demonstrated experimentally. The open FP cavity has been fabricated on the end face of an FBG by dislocation fusion in this work, the open FP cavity could be used for refractive index sensing, and the temperature is measured by the FBG. The working principle of the sensor and the method of improving the sensitivity are analyzed by theoretical simulation. The refractive index sensitivity of the sensor is 1 108.4 nm/RIU, while the maximum fluctuation of the sensor stability experiment detection is 0.005 nm. The results show that it has satisfactory characteristics. The sensor is a compact all-fiber structure, so it has potential applications in the field of temperature refractive index sensing, such as biomedical and capacitor electrolyte detection.
引用
收藏
页码:477 / 482
页数:6
相关论文
共 50 条
  • [21] Simultaneous measurement of temperature and refractive index based on a Mach-Zehnder interferometer cascaded with a fiber Bragg grating
    Cao, Ye
    Liu, Huiying
    Tong, Zhengrong
    Yuan, Shuo
    Su, Jun
    OPTICS COMMUNICATIONS, 2015, 342 : 180 - 183
  • [22] Time domain crosstalk in fiber Bragg grating Fabry-Pérot interferometric hydrophone array system
    Guo Z.
    Gao K.
    Zhou S.
    Sha J.
    Guangxue Xuebao/Acta Optica Sinica, 2016, 36 (07):
  • [23] Simultaneous measurement of temperature and refractive index based on microfiber Bragg Grating in Sagnac loop
    Cao, Yanpeng
    Zhang, Hongmin
    Miao, Yinping
    Ma, Zelong
    Li, Bin
    OPTICAL FIBER TECHNOLOGY, 2019, 47 : 147 - 151
  • [24] Simultaneous measurement of temperature and refractive index with thin-core fiber MZI containing fiber Bragg grating
    Zhou, Menghui
    Dong, Xinyong
    Liu, Xiaohang
    2017 16TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS & NETWORKS (ICOCN 2017), 2017,
  • [25] Simultaneous Measurement of Refractive Index and Temperature Using a Hybrid Fiber Bragg Grating/Long-Period Fiber Grating Configuration
    Jesus, C.
    Caldas, P.
    Frazao, O.
    Santos, J. L.
    Jorge, P. A. S.
    Baptista, J. M.
    FIBER AND INTEGRATED OPTICS, 2009, 28 (06) : 440 - 449
  • [26] Fiber Bragg grating cavity sensor for simultaneous measurement of strain and temperature
    Du, WC
    Tao, XM
    Tam, HY
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1999, 11 (01) : 105 - 107
  • [27] Asymmetric Fabry-Pérot interferometric cavity for fiber optical sensors
    江绍基
    梁有程
    朱析
    汪河洲
    ChineseOpticsLetters, 2006, (10) : 563 - 565
  • [28] High-Q Fabry-Pérot Cavity Based on Micro-Lens Array for Refractive Index Sensing
    Wang, Qi
    Zhao, Xuyang
    Luo, Man
    Li, Yuxiang
    Liu, Junjie
    Wu, Xiang
    PHOTONIC SENSORS, 2024, 14 (04)
  • [29] Experimental measurement of the quality factor of a Fabry-Pérot open-cavity axion haloscope
    Hernandez-Cabrera, Juan F.
    De Miguel, Javier
    Hernandez-Suarez, E.
    Joven-Alvarez, Enrique
    Lorenzo-Hernandez, H.
    Otani, Chiko
    Rapado-Tamarit, Miguel A.
    Rubino-Martin, J. Alberto
    JOURNAL OF INSTRUMENTATION, 2024, 19 (01)
  • [30] A Simplified Fabrication Technique for Tilted Fiber Bragg Grating for The Simultaneous Measurement of Refractive Index and Temperature of Liquids
    Kameyama, Akihiro
    Katto, Masahito
    Yokotani, Atsushi
    JOURNAL OF LASER MICRO NANOENGINEERING, 2014, 9 (03): : 230 - 233