Study of a 105 GHz short-pulse dummy load for the electron cyclotron resonance heating system with the quasi-optical method

被引:0
|
作者
熊寿齐 [1 ]
夏冬辉 [1 ]
黄梅 [2 ]
陈罡宇 [2 ]
翁文婷 [1 ]
范国垚 [2 ]
潘垣 [1 ]
机构
[1] International Joint Research Laboratory of Magnetic Confinement Fusion and Plasma Physics, State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Tech
[2] Southwestern Institute of
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The accurate power measurement is important for an ECRH system in tokamak. The dummy load is designed and developed for the measurement of the millimeter wave power. This work analyzes the dummy load based on the quasi-optical method and the ray tracing method. The reflectivity and thermal deposition of the dummy load have been considered to ensure the safety of the entire system. High-power tests have been carried out at a 105 GHz/500 kW ECRH system. The results of the tests indicate that the designed dummy load is stable and valid.
引用
收藏
页码:158 / 165
页数:8
相关论文
共 25 条
  • [21] Commissioning results of the 0.5 MW/68 GHz/1.0 s gyrotron on HL-2A electron cyclotron resonance heating system
    Wang, He
    Rao, Jun
    Huang, Mei
    Zhou, Jun
    Wang, Chao
    Rang, Zihua
    Wang, Mingwei
    Feng, Run
    Chen, Gangyu
    Lu, Bo
    Wang, Jieqiong
    FUSION ENGINEERING AND DESIGN, 2015, 101 : 61 - 66
  • [22] THE EBT-S 28-GHZ, 200-KW, CW, MIXED-MODE, QUASI-OPTICAL PLASMA-HEATING SYSTEM
    WHITE, TL
    KIMREY, HD
    BIGELOW, TS
    BATES, DD
    EASON, HO
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1984, 5 (08): : 1129 - 1152
  • [23] A Study on the Performance of the Cryostat System for the 28-GHz Electron Cyclotron Resonance Ion Source at the Korea Basic Science Institute
    Jonggi Hong
    Jin Yong Park
    Sung Jun Kim
    Jung-Woo Ok
    Seyong Choi
    Journal of the Korean Physical Society, 2020, 77 : 404 - 408
  • [24] A Study on the Performance of the Cryostat System for the 28-GHz Electron Cyclotron Resonance Ion Source at the Korea Basic Science Institute
    Hong, Jonggi
    Park, Jin Yong
    Kim, Sung Jun
    Ok, Jung-Woo
    Choi, Seyong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (05) : 404 - 408
  • [25] Production of intense 58Fe, 64Ni beam using the MIVOC method and new analyzing system of RIKEN 18 GHz electron cyclotron resonance ion source
    Kidera, M
    Nakagawa, T
    Higurashi, Y
    Aihara, T
    Suzuki, N
    Ikezawa, E
    Kamigaito, O
    Kase, M
    Yano, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1473 - 1475