Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch

被引:0
|
作者
姚学玲 [1 ]
陈景亮 [1 ]
孙伟 [2 ]
机构
[1] Electrical Engineering Institute of Xi'an Jiaotong University,State Key Laboratory of Electrical Insulation and Power Equipment
[2] Mechanical and Electrical Engineering Dept,Xi'an University of Architecture and
关键词
D O I
暂无
中图分类号
TM564.2 [负荷开关];
学科分类号
摘要
<正> Triggering characteristics of triggered vacuum switch (TVS),including the dischargedelay time,delay jitter,range of operational voltage and peak of pulsed current,are investigated.Both structure and experimental circuit of TVS are presented.The results indicate that TVS,asa surface flashover triggering device with high dielectric permittivity material,is with excellenttriggering characteristics.When the hold-off voltage reaches 120 kV,the minimum operationalvoltage is 1.3 kV,and the minimum discharge delay time and jitter are 100 ns and ±10 ns,respectively.The peak current is up to 240 kA when the operational voltage reaches 100 kV.TVScan well satisfy the main demands of high voltage and current applications,and can also be usedunder a multi-crowbar circuit.
引用
收藏
页码:734 / 737
页数:4
相关论文
共 50 条
  • [41] Research on the Triggering Mechanism of Laser Triggered Vacuum Switch with Different Polarities
    Zhao T.
    Liao M.
    Chen Z.
    Fan Z.
    Zou J.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (15): : 3341 - 3347
  • [42] Characteristics of laser-triggered vacuum switch
    Fukushi, I
    Watanabe, M
    Hotta, E
    Okino, A
    Ko, KC
    ISDEIV: XIXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2000, 19 : 511 - 514
  • [43] Experimental Study on the Initial Current Characteristics of Laser-Triggered Vacuum Switch During Trigger Process
    Lu, Gang
    Liao, Minfu
    Zhang, Ming
    Sun, Yifan
    Ou, Jian
    Duan, Xiongying
    Han, Xiaotao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (04) : 1844 - 1849
  • [44] Study on Inherent Dielectric Recovery Characteristics of Laser Triggered Vacuum Switch
    Zhang, Hubo
    Liao, Minfu
    Chen, Zhanqing
    Sun, Yijie
    Sun, Wenhao
    Dalian, Ming Zhang
    29TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2020), 2021, : 315 - 318
  • [45] Study on High Frequency Breaking Characteristics of Laser Triggered Vacuum Switch
    Liu, Xu
    Liao, Minfu
    Chen, Zhanqing
    Duan, Xiongying
    Zou, Jiyan
    Zhao, Tong
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 2, 2018, : 519 - 522
  • [46] Investigation of the Impedance Characteristics During the Turn-On Process of Electrically Triggered Vacuum Surface Flashover Switches
    Fu, Yingjie
    Ye, Mingtian
    Dong, Luokang
    Feng, Bingyang
    Qin, Shenyi
    He, Mengbing
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (02) : 834 - 843
  • [47] Triggering characteristics of SF gas switch triggered by XeCl laser
    China Inst of Atomic Energy, Academia Sinica, Beijing, China
    Qiangjiguang Yu Lizishu, 1 (68-74):
  • [48] Research on Temperature Characteristics of DC Surface Flashover in Vacuum
    Zhang, Zhenjun
    Shao, Mingyan
    Zhu, Zhenhua
    Li, Na
    Xu, Ran
    Wang, Yanan
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1345 - 1349
  • [49] Dielectric surface flashover in vacuum - Experimental design issues
    Sudarshan, TS
    Li, CR
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1997, 4 (05) : 657 - 662
  • [50] Characteristics on Surface flashover of polyethylene nanocomposites film in vacuum
    Wang, Weiwang
    Li, Shengtao
    Tang, Fan
    Li, Jianying
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1055 - 1058