Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter

被引:0
|
作者
庄兆意
张承虎
王海燕
孙德兴
机构
[1] SchoolofMunicipalandEnvironmentalEngineering,HarbinInstituteofTechnology
关键词
D O I
暂无
中图分类号
X703 [废水的处理与利用]; TU831 [空气调节];
学科分类号
080705 ;
摘要
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [31] Alternate operation characteristics of a solar-ground source heat pump system
    Yang, Weibo
    Chen, Zhenqian
    Shi, Mingheng
    Journal of Southeast University (English Edition), 2010, 26 (02) : 327 - 332
  • [32] The Alternate Operation Characteristics of a Solar-ground Source Heat Pump System
    Yang, Weibo
    Shi, Mingheng
    Chen, Zhenqian
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1816 - 1824
  • [33] System simulation of an untreated sewage source heat pump
    Qin N.
    Hao Z.
    International Journal of Simulation: Systems, Science and Technology, 2016, 17 (29): : 27.1 - 27.9
  • [34] Applications and Future Development of Sewage Source Heat Pump
    Yu, Yu
    Li, Hui
    Wang, Lin
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOLOGICAL ENGINEERING AND PHARMACY (BEP 2016), 2016, 3 : 332 - 334
  • [35] Design and analysis of gas engine heat pump using sludge as material and sewage as heat source
    Jiang, Yun-Tao
    Ma, Yi-Tai
    Yang, Zhao
    Li, Min-Xia
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (08): : 1275 - 1278
  • [36] Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger
    Michopoulos, A.
    Zachariadis, T.
    Kyriakis, N.
    ENERGY, 2013, 51 : 349 - 357
  • [37] Progress of the intaking, defouling and heat transfer in sewage water side of the sewage water source heat pump system Part II: Research on urban sewage source heat pump in China
    Zhang, Jili
    Ma, Liangdong
    Liang, Ruobing
    Zhao, Tianyi
    Ma, Zhixian
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1624 - 1631
  • [38] The Operation Strategy Analysis of Reclaimed Water Source Heat Pump System
    Liu, Meng
    Cui, Minghui
    2015 INTERNATIONAL CONFERENCE ON NEW ENERGY SCIENCE AND RESEARCH (ICESR 2015), 2015, : 538 - 543
  • [39] Experimental study on the performance of air source heat pump system with multiple parallel outdoor units
    Niu Jianhui
    Ma Guoyuan
    Xu Shuxue
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (04) : 2819 - 2832
  • [40] The thermal characteristics of a helical coil heat exchanger for seawater-source heat pump in cold winter
    Zheng, Wadong
    Zhang, Huan
    You, Shijun
    Ye, Tianzhen
    8TH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2016, 146 : 548 - 557