Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter

被引:0
|
作者
庄兆意
张承虎
王海燕
孙德兴
机构
[1] SchoolofMunicipalandEnvironmentalEngineering,HarbinInstituteofTechnology
关键词
D O I
暂无
中图分类号
X703 [废水的处理与利用]; TU831 [空气调节];
学科分类号
080705 ;
摘要
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [1] Parallel operation characteristics analysis of sewage source heat pump units in winter
    Zhuang Z.
    Zhang C.
    Wang H.
    Sun D.
    Transactions of Tianjin University, 2010, 16 (06) : 461 - 466
  • [2] Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter
    庄兆意
    张承虎
    王海燕
    孙德兴
    Transactions of Tianjin University, 2010, 16 (06) : 461 - 466
  • [3] The operation characteristics of sewage source heat pump system and the analysis of its thermal economic benefits
    Qin, Na
    Hao, Peng Z.
    APPLIED THERMAL ENGINEERING, 2017, 124 : 1083 - 1089
  • [4] Analysis on operation characteristics of wind source heat pump system
    Zhang, Yongzhi
    Gu, Jie
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 818 - 821
  • [5] SYSTEM SIMULATION FOR AN UNTREATED SEWAGE SOURCE HEAT PUMP (USSHP) IN WINTER
    Qin, Na
    Hao, Peng Z.
    SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2017, 10322
  • [6] Study on optimization of winter operation characteristics of solar-ground source heat pump in Shanghai
    Qi, Zihao
    Cai, Yingling
    Cui, Yunxiang
    RENEWABLE ENERGY, 2024, 220
  • [7] Analysis of Fouling in Sewage Source Heat Pump Heat Exchanger
    Zhang, Xu
    Zhang, Lingzhe
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND TRANSPORTATION 2015, 2016, 30 : 804 - 808
  • [8] Characteristics of Fouling in Urban Sewage Source Heat Pump System
    Zhang, Chenghu
    Yang, Zhigang
    Sun, Dexing
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 1502 - 1505
  • [9] ECONOMICS ANALYSIS OF SEWAGE SOURCE HEAT PUMP SYSTEM
    Bing, Wei
    Bin, Zhang
    Lu, Jiang
    Wen, Luo
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2009, : 547 - 552
  • [10] Flow Characteristics of the Raw Sewage for the Design of Sewage-Source Heat Pump Systems
    Xu, Ying
    Wu, Yuebin
    Sun, Qiang
    SCIENTIFIC WORLD JOURNAL, 2014,