A series of numerical analyses has been performed on the characteristics of heat transfer in a closed-loop vertical ground heat exchanger(U-loop).A 2-D finite element analysis was conducted to evaluate the temperature distribution over the cross section of the U-loop system involving high-density polyethylene(HDPE) pipe/grout/soil to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system,which is equipped with a thermally insulating lattice in order to reduce thermal interference between the inlet and outlet pipes.In addition,a 3-D finite volume analysis(FLUENT) was adopted to simulate the operation of the closed-loop vertical ground heat exchanger with the consideration of the effect of a distance between the inlet and outlet pipes,grout's thermal properties,the effectiveness of the latticed HDPE pipe system,and the rate of circulation pump.It was observed that the thermal interference between the two strands of U-loop is of importance in enhancing efficiency of the ground heat exchanger.Consequently,it is recommended to modify the configuration of the conventional U-loop system by equipping the thermally insulating lattice between the two pipe strands.
引用
收藏
页码:111 / 116
页数:6
相关论文
共 50 条
  • [31] An Analysis of economical efficiency of closed-loop vertical ground source heat pump system applied in school
    Yang, Seung-Jin
    Park, Sang-Ho
    Kim, Ju-Young
    Hong, Won-Hwa
    6TH INTERNATIONAL SYMPOSIUM OF ASIA INSTITUTE OF URBAN ENVIRONMENT: ENERGY CONSERVATION AND CARBON OFF IN ASIA CITY, 2009, : 323 - 326
  • [32] Vaporization thermal power assurance for vertical closed-loop ground-coupled heat pump systems
    Sarbu, Ioan
    Bura, Horia
    ADVANCES IN BIOLOGY, BIOENGINEERING AND ENVIRONMENT, 2010, : 125 - +
  • [33] Investigation of buoyancy effects on heat transfer between a vertical borehole heat exchanger and the ground
    Sharqawy, Mostafa H.
    Badr, Hassan M.
    Mokheimer, Esmail M.
    GEOTHERMICS, 2013, 48 : 52 - 59
  • [34] Heat transfer characteristics of a novel closed-loop pulsating heat pipe with a check valve
    Feng, Chen
    Wan, Zhenping
    Mo, Haijun
    Tang, Heng
    Lu, Longsheng
    Tang, Yong
    APPLIED THERMAL ENGINEERING, 2018, 141 : 558 - 564
  • [35] Closed-Loop Energy Flow Redistribution for Optimal Operation of Heat Exchanger Networks
    Mohanan, Karthika
    Jogwar, Sujit S.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (28) : 11082 - 11095
  • [36] EFFECTS OF HEAT-LOSSES (OR GAINS) FROM INSULATED PORTIONS OF CLOSED-LOOP THERMOSIPHONS WITH VERTICAL HEAT-TRANSFER SECTIONS
    BERNIER, MA
    BALIGA, BR
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1993, 115 (02): : 480 - 482
  • [37] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [38] Innovative High Efficiency Closed Loop Ground Coupled Heat exchanger (GCHE)
    Chaldezos, I. P.
    Karytsas, C. S.
    SUSTAINABLE SYNERGIES FROM BUILDINGS TO THE URBAN SCALE, 2017, 38 : 102 - 106
  • [39] Numerical analysis of heat transfer induced by an horizontal ground heat exchanger in an heterogeneous soil
    Bottarelli, Michele
    International Journal of Heat and Technology, 2010, 28 (02) : 141 - 146
  • [40] Three dimensional numerical heat transfer model of pile spiral ground heat exchanger
    Huang, Guangqin (hgq880818@163.com), 1600, Science Press (37):