ION OPTICS OF A TIME-OF-FLIGHT MASS-SPECTROMETER WITH ELECTROSTATIC SECTOR ANALYZERS

被引:3
|
作者
SAKURAI, T
ITO, H
MATSUO, T
机构
[1] Department of Physics, Faculty of Science, Osaka University, Toyonaka
关键词
D O I
10.1016/0168-9002(95)00420-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ion optics for a high resolution time-of-flight mass spectrometer with electrostatic sector analyzers have been investigated. The multiple focusing (triple isochronous focusing and triple spacial focusing) conditions can be achieved by using a symmetrical arrangement of the sectors in a mass spectrometer. Both high mass resolution and high ion transmission can be accomplished simultaneously. The principles of MS/MS and MS/MS/MS analyses using a TOF mass spectrometer with electrostatic sector analyzers have been proposed. Product ion spectra can be obtained by measuring the total night times and the kinetic energy of the products without any additional separation processes, any coincidence techniques or any special timing circuits. In an experiment, MS/MS and MS/MS/MS mass spectra have been obtained. The first generation product ions have been produced by a metastable decay, and the second generation products have been produced by a sequential decay.
引用
收藏
页码:426 / 428
页数:3
相关论文
共 50 条
  • [41] STUDY OF POSITIVE-ION EMISSION OF MOLYBDENUM BY MEANS OF A TIME-OF-FLIGHT MASS-SPECTROMETER
    KARACSON.R
    KAPOSI, O
    HOBINKA, I
    RIEDEL, M
    PODMANIC.I
    ACTA CHIMICA ACADEMIAE SCIENTARIUM HUNGARICAE, 1972, 74 (02): : 169 - &
  • [42] THE DESIGN AND PERFORMANCE OF AN ION-TRAP STORAGE REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    CHIEN, BM
    MICHAEL, SM
    LUBMAN, DM
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 149 - 179
  • [43] AN ISOCHRONOUS POLOIDAL GEOMETRY TIME-OF-FLIGHT ION MASS-SPECTROMETER FOR ENERGETIC SPACE PLASMAS
    YOUNG, DT
    MARSHALL, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 298 (1-3): : 227 - 233
  • [44] REFLECTING TIME-OF-FLIGHT MASS-SPECTROMETER WITH AN ELECTROSPRAY ION-SOURCE AND ORTHOGONAL EXTRACTION
    VERENTCHIKOV, AN
    ENS, W
    STANDING, KG
    ANALYTICAL CHEMISTRY, 1994, 66 (01) : 126 - 133
  • [45] MASS RESOLUTION OF 10000 IN A LASER IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETER
    WALTER, K
    BOESL, U
    SCHLAG, EW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 71 (03): : 309 - 313
  • [46] PHOTODISSOCIATION OF MAGNESIUM-ION MOLECULE COMPLEXES IN A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    YEH, CS
    WILLEY, KF
    ROBBINS, DL
    DUNCAN, MA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 307 - 317
  • [47] TIME-OF-FLIGHT MASS ANALYZERS
    WOLLNIK, H
    MASS SPECTROMETRY REVIEWS, 1993, 12 (02) : 89 - 114
  • [48] INTERFACE DEVELOPMENT FOR COMPUTER CONTROL OF A TIME-OF-FLIGHT MASS-SPECTROMETER
    BLACKMON, BW
    ENGLISH, RD
    HALES, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 314 - CHED
  • [49] THE TIME-OF-FLIGHT MASS-SPECTROMETER - A POOR MANS SIMS DEVICE
    KLOTS, CE
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1981, 37 (02): : 195 - 202
  • [50] BEAM COMPRESSION AND BEAM MULTIPLEXING IN A TIME-OF-FLIGHT MASS-SPECTROMETER
    RIESS, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (05): : 784 - 787