INFLUENCE OF BIOFILMS ON MICROBIAL-CONTAMINATION IN DENTAL UNIT WATER

被引:55
|
作者
WHITEHOUSE, RLS [1 ]
PETERS, E [1 ]
LIZOTTE, J [1 ]
LILGE, C [1 ]
机构
[1] UNIV ALBERTA,DEPT ORAL BIOL,EDMONTON T6G 2H7,ALBERTA,CANADA
关键词
EQUIPMENT; MICROBIOLOGY; BIOFILMS;
D O I
10.1016/0300-5712(91)90075-A
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Water from dental units (DU), used for cooling and clearing the field of dental operations, is frequently contaminated by microorganisms. Retrograde spread of oral microbes into DU tubing, contaminated plumbing systems and endogenous DU contamination have been implicated. This study investigated the contribution of DU tubing to this contamination in 11 randomly selected DU. The times required, under standardized conditions, for DU bacterial levels to decrease in response to the flushing caused by DU operation, or increase in response to stagnation caused by shutting down the DU, were measured. The DU tubing was then removed and similarly manipulated. The results showed similar bacterial levels and populations in the DU and their corresponding tubes. Sixteen control samples taken from the connecting plumbing system at distant locations, after periods of stagnation which result in DU bacterial contamination, were negative. This suggests the plumbing, in our system, is not an important factor. Thus, DU can endogenously contaminate the water passing through them; their tubes have the potential to generate similar magnitudes of bacterial contamination to that determined from intact DU. Scanning electron microscopy of the tube lumens showed a biofilm, characterized by microorganisms embedded in an amorphous matrix in all cases. This biofilm could act as a reservoir to facilitate rapid recontamination. Further analysis of the data indicates there could be other contributing factors.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 50 条
  • [31] MICROBIAL-CONTAMINATION OF ANESTHETIC MACHINES
    GROSS, A
    RUSSELL, EA
    JOURNAL OF DENTAL RESEARCH, 1979, 58 : 400 - 400
  • [32] COMPARISON OF RESISTANCE TO MICROBIAL-CONTAMINATION OF CONVENTIONAL AND MODIFIED WATER DISPENSERS
    ECKNER, KF
    JOURNAL OF FOOD PROTECTION, 1992, 55 (08) : 627 - 631
  • [33] Microbial contamination in dental unit airlines.
    Miller, CH
    Waskow, JR
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2163 - 2163
  • [34] Microbial biofilm formation and contamination of dental-unit water systems in general dental practice
    Walker, JT
    Bradshaw, DJ
    Bennett, AM
    Fulford, MR
    Martin, MV
    Marsh, PD
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2000, 66 (08) : 3363 - 3367
  • [35] Control of microbial contamination in dental unit waterlines: Effectiveness of neutral electrolytic water
    Mishima, Sayaka
    Watanabe, Takuma
    Fukuhara, Shizuko
    Ymanaka, Shigeki
    Nakao, Kazumasa
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (03) : 512 - 517
  • [36] MICROBIAL-CONTAMINATION ASSOCIATED WITH HOSPITAL FLUIDS
    BROWN, DG
    CRC CRITICAL REVIEWS IN ENVIRONMENTAL CONTROL, 1980, 9 (03): : 279 - 299
  • [37] MICROBIAL-CONTAMINATION OF MULTIUSE EYEDROP DISPENSERS
    JACKSON, WB
    STONGE, PD
    MOIR, P
    WOJCIECHOWSKI, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1671 - 1671
  • [38] PROBLEMS OF MICROBIAL-CONTAMINATION IN PHARMACEUTICAL SERVICES
    HILBIG, B
    SCHOBESS, B
    VATER, U
    VATER, W
    WALKER, R
    PHARMAZIE, 1981, 36 (02): : 147 - 154
  • [39] MICROBIAL-CONTAMINATION OF SPICES AND HERBS - A REVIEW
    MCKEE, LH
    FOOD SCIENCE AND TECHNOLOGY-LEBENSMITTEL-WISSENSCHAFT & TECHNOLOGIE, 1995, 28 (01): : 1 - 11
  • [40] MICROBIAL-CONTAMINATION OF COTTON BRACT AND LINT
    MOREY, PR
    FISCHER, JJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 188 (AUG): : 31 - CELL