MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY - A COMPARISON OF [O-15]WATER TO [C-11] BUTANOL WITH DISTRIBUTED-PARAMETER AND COMPARTMENTAL-MODELS

被引:33
|
作者
QUARLES, RP
MINTUN, MA
LARSON, KB
MARKHAM, J
MACLEOD, AM
RAICHLE, ME
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,DIV RADIAT SCI,510 S KINGSHIGHWAY,ST LOUIS,MO 63110
[2] UNIV FLORIDA,DEPT RADIOL,GAINESVILLE,FL 32611
[3] UNIV PITTSBURGH,DIV NUCL MED,PITTSBURGH,PA 15260
[4] WASHINGTON UNIV,DEPT NEUROL & NEUROSURG,ST LOUIS,MO 63130
[5] WASHINGTON UNIV,INST BIOMED COMP,ST LOUIS,MO 63130
来源
关键词
BLOOD FLOW TRACERS; BRAIN ACTIVATION; COMPARTMENTAL MODELS; DISPERSION AND DELAY; DISTRIBUTED-PARAMETER MODELS; POSITRON EMISSION TOMOGRAPHY; REGIONAL CEREBRAL BLOOD FLOW;
D O I
10.1038/jcbfm.1993.94
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To further our understanding of the best way to measure regional CBF with positron emission tomography (PET), we directly compared two candidate tracers ([O-15]water and [C-11]butanol, administered intravenously) and two popular implementations of the one-compartment (1C) model: the autoradiographic implementation representing a single PET measurement of tissue radioactivity over 1 min and a dynamic implementation representing a sequence of measurements of tissue radioactivity over 200 s. We also examined the feasibility of implementing a more realistic, and thus more complex, distributed-parameter (DP) model by assigning fixed values for all of its parameters other than CBF and tracer volume of distribution (Vd), a requirement imposed by the low temporal resolution and statistical quality of PET data. The studies were performed in three normal adult human subjects during paired rest and visual stimulation. In each subject seven regions of interest (ROIs) were selected, one of which was the primary visual cortex. The corresponding ROI were anatomically equivalent in the three subjects. Regional CBF, V(d), tracer arrival delay, and dispersion were estimated for the dynamic data curves. A total of 252 parameter sets were estimated. With [C-11]butanol both implementations of the 1C model provided similar results (r = 0.97). Flows estimated using the 1C models were lower (p < 0.01) with [O-15]water than with [C-11]butanol. In comparison with the 1C model, the constrained version of the DP used in these studies performed inadequately, overestimating high flow and underestimating low flow with both tracers, possibly as the result of the necessity of assigning fixed values for all of its parameters other than CBF and V(d).
引用
下载
收藏
页码:733 / 747
页数:15
相关论文
共 50 条
  • [31] VARIABILITY OF THE REGIONAL CEREBRAL BLOOD-FLOW PATTERN STUDIED WITH [C-11] FLUOROMETHANE AND POSITION EMISSION TOMOGRAPHY (PET)
    SEITZ, RJ
    ROLAND, PE
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1992, 16 (05) : 311 - 322
  • [32] QUANTITATIVE MEASUREMENT OF RENAL PLASMA-FLOW BY POSITRON EMISSION TOMOGRAPHY WITH O-15 WATER
    INABA, T
    YAMASHITA, M
    KAWASE, Y
    NAKAHASHI, H
    WATANABE, H
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1989, 159 (04): : 283 - 289
  • [33] NONINVASIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW CHANGE WITH (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY USING A MECHANICAL INJECTOR AND A STANDARD ARTERIAL INPUT FUNCTION
    SADATO, N
    YONEKURA, Y
    SENDA, M
    MAGATA, Y
    IWASAKI, Y
    MATOBA, N
    TSUCHIDA, T
    TAMAKI, N
    FUKUYAMA, H
    SHIBASAKI, H
    KONISHI, J
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 703 - 710
  • [34] QUANTITATIVE MEASUREMENT OF MYOCARDIAL BLOOD-FLOW WITH O-15 WATER AND POSITRON COMPUTED-TOMOGRAPHY - AN ASSESSMENT OF POTENTIAL AND PROBLEMS
    HUANG, SC
    SCHWAIGER, M
    CARSON, RE
    CARSON, J
    HANSEN, H
    SELIN, C
    HOFFMAN, EJ
    MACDONALD, N
    SCHELBERT, HR
    PHELPS, ME
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (06) : 616 - 625
  • [35] QUANTITATION OF MYOCARDIAL BLOOD-FLOW WITH (H2O)O-15 AND POSITRON EMISSION TOMOGRAPHY (PET)
    BERGMANN, SR
    MYEARS, DW
    WALSH, MN
    WEINHEIMER, CJ
    GELTMAN, EM
    MARKHAM, J
    HERRERO, P
    CIRCULATION, 1987, 76 (04) : 116 - 116
  • [36] SEPARATE EFFECTS OF INSTRUCTIONS AND STIMULI ON CEREBRAL BLOOD-FLOW - A O-15 POSITRON EMISSION TOMOGRAPHIC STUDY
    CHERTKOW, HM
    BUB, D
    WATERS, G
    EVANS, A
    WHITEHEAD, V
    HOSEIN, C
    NEUROLOGY, 1993, 43 (04) : A189 - A189
  • [37] MEASUREMENT OF CEREBRAL BLOOD-FLOW USING BOLUS INHALATION OF (CO2)-O-15 AND POSITRON EMISSION TOMOGRAPHY - DESCRIPTION OF THE METHOD AND ITS COMPARISON WITH THE (CO2)-O-15 CONTINUOUS INHALATION METHOD
    KANNO, I
    LAMMERTSMA, AA
    HEATHER, JD
    GIBBS, JM
    RHODES, CG
    CLARK, JC
    JONES, T
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (02): : 224 - 234
  • [38] A COMPARISON BETWEEN REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS OBTAINED IN HUMAN-SUBJECTS USING C-11 METHYLALBUMIN MICROSPHERES, THE C15O2 STEADY-STATE METHOD, AND POSITRON EMISSION TOMOGRAPHY
    BROOKS, DJ
    FRACKOWIAK, RSJ
    LAMMERTSMA, AA
    HEROLD, S
    LEENDERS, KL
    SELWYN, AP
    TURTON, DR
    BRADY, F
    JONES, T
    ACTA NEUROLOGICA SCANDINAVICA, 1986, 73 (04): : 415 - 422
  • [39] THE AUTORADIOGRAPHIC MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW (CBF) WITH POSITRON EMISSION TOMOGRAPHY - VALIDATION STUDIES
    HERSCOVITCH, P
    MARTIN, WRW
    RAICHLE, ME
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P62 - P63
  • [40] REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENT WITH INTRAVENOUS [O-15]WATER BOLUS AND [F-18] FLUOROMETHANE INHALATION
    HERHOLZ, K
    PIETRZYK, U
    WIENHARD, K
    HEBOLD, I
    PAWLIK, G
    WAGNER, R
    HOLTHOFF, V
    KLINKHAMMER, P
    HEISS, WD
    STROKE, 1989, 20 (09) : 1174 - 1181