Carbon Nanotube-Based Electrochemical Sensor for the Determination of Anthraquinone Hair Dyes in Wastewaters

被引:11
|
作者
de Oliveira, Ricardo [1 ]
Hudari, Felipe [1 ]
Franco, Jefferson [1 ]
Boldrin Zanoni, Maria Valnice [1 ]
机构
[1] Univ Estadual Paulista, Inst Quim Araraquara, Dept Quim Analit, UNESP, Rua Francisco Degni 55, BR-14800900 Araraquara, SP, Brazil
来源
CHEMOSENSORS | 2015年 / 3卷 / 01期
基金
巴西圣保罗研究基金会;
关键词
temporary hair dye; voltammetric sensor; carbon nanotubes; Acid Green 25;
D O I
10.3390/chemosensors3010022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work describes the development of a voltammetric sensor for the selective determination of Acid Green 25 (AG25) hair dye, widely used in commercial temporary hair dyes. The method is based on a glassy carbon electrode modified with multiwalled carbon nanotubes activated in the presence of sulfuric acid, where the anthraquinone group present as a chromophore in the dye molecule is reduced at -0.44 V vs. Ag/AgCl in a reversible process involving two electrons in Britton-Robinson (B-R) buffer solution at pH 4.0. Analytical curves were obtained using square wave voltammetry in the range from 1.0 x 10(-7) to 7.0 x 10(-6) molL(-1), achieving a detection limit of 2.7 x 10(-9) molL(-1). The voltammograms recorded for the Acid Black 1 (AB1) dye showed that the azo groups of the dye were reduced on the carbon nanotube-modified electrode (CNTME), presenting a pair of redox peaks at -0.27 V and -0.24 V in the reverse scan. Under these experimental conditions, both dyes could be detected in the water sample, since the AG25 dye is reduced at -0.47 V. The presence of other hair dyes bearing other chromophore groups, such as Acid Black 1, Acid Red 33 and basic blue 99, did not interfere with the method, which showed an average recovery of 96.7 +/- 3.5% (n = 5) for AG25 dye determination in the presence of all of these dyes. The method was successfully applied to tap water and wastewater samples collected from a water treatment plant.
引用
下载
收藏
页码:22 / 35
页数:14
相关论文
共 50 条
  • [1] Carbon nanotube-based electrochemical sensor for the determination of halobetasol propionate, a topical corticosteroid
    Goyal, Rajendra N.
    Agrawal, Bharati
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (01) : 31 - 39
  • [2] Carbon nanotube-based electrochemical sensor for the determination of halobetasol propionate, a topical corticosteroid
    Rajendra N. Goyal
    Bharati Agrawal
    Journal of Applied Electrochemistry, 2012, 42 : 31 - 39
  • [3] Multi-wall carbon nanotube-based electrochemical sensor for sensitive determination of Sudan I
    Gan, Tian
    Li, Kai
    Wu, Kangbing
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) : 134 - 139
  • [4] A carbon nanotube-based radiation sensor
    Ma, J.
    Yeow, J.T.W.
    Chow, J.C.L.
    Barnett, R.B.
    International Journal of Robotics and Automation, 2007, 22 (01): : 49 - 57
  • [5] A carbon nanotube-based pressure sensor
    Karimov, Kh S.
    Saleem, M.
    Karieva, Z. M.
    Khan, Adam
    Qasuria, T. A.
    Mateen, A.
    PHYSICA SCRIPTA, 2011, 83 (06)
  • [6] A carbon nanotube-based radiation sensor
    Ma, J.
    Yeow, J. T. W.
    Chow, J. C. L.
    Barnett, R. B.
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2007, 22 (01): : 49 - 58
  • [7] Nanomolar detection limit for determination of norepinephrine in the presence of acetaminophen and tryptophan using carbon nanotube-based electrochemical sensor
    Mohammad Mazloum-Ardakani
    Mohammad Ali Sheikh-Mohseni
    Bibi-Fatemeh Mirjalili
    Ionics, 2014, 20 : 431 - 437
  • [8] Novel electrochemical method for sensitive determination of homocysteine with carbon nanotube-based electrodes
    Gong, KP
    Dong, Y
    Xiong, SX
    Chen, Y
    Mao, LQ
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (02): : 253 - 259
  • [9] Nanomolar detection limit for determination of norepinephrine in the presence of acetaminophen and tryptophan using carbon nanotube-based electrochemical sensor
    Mazloum-Ardakani, Mohammad
    Sheikh-Mohseni, Mohammad Ali
    Mirjalili, Bibi-Fatemeh
    IONICS, 2014, 20 (03) : 431 - 437
  • [10] Development of Multiwalled Carbon Nanotube Based Electrochemical Sensor for Reactive Azo dyes
    Valarmathi, Munirathinam
    Gomathi, Anandhan
    Manisankar, Paramasivam
    ADVANCES IN NANOSCIENCE AND NANOTECHNOLOGY, 2013, 678 : 321 - +