COMPARISON OF REAGENT STRIP (DIPSTICK) AND MICROSCOPIC HEMATURIA IN UROLOGICAL OUT-PATIENTS

被引:19
|
作者
GLEESON, MJ [1 ]
CONNOLLY, J [1 ]
GRAINGER, R [1 ]
MCDERMOTT, TED [1 ]
BUTLER, MR [1 ]
机构
[1] MEATH HOSP,DEPT UROL,DUBLIN,IRELAND
来源
BRITISH JOURNAL OF UROLOGY | 1993年 / 72卷 / 05期
关键词
D O I
10.1111/j.1464-410X.1993.tb16215.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Dipstick (reagent strip) and microscopic urine analysis for haematuria was performed prospectively on 1000 consecutive urine samples taken from urological out-patients. Haematuria was present in 185 samples (1 8.5%) and absent in 687 (68.7%) using both tests; 98 samples (9.8%) had dipstick haematuria that was not confirmed by microscopy and 30 samples (3%) had microscopic haematuria that was missed on dipstick urine analysis. Dipstick urine analysis had a sensitivity of 86. 1 % and a specificity of 85%. This study confirms that reagent strip testing for haematuria has both false positive and false negative results and indicates that cytoscopy should be considered in all patients with suspected haematuria.
引用
下载
收藏
页码:594 / 596
页数:3
相关论文