Abdominal aorta aneurysm: Case report of high radiation dose during stent-graft implantation

被引:0
|
作者
Majewska, Natalia [1 ]
Juszkat, Robert [1 ]
Blaszak, Magdalena [2 ]
Frankiewicz, Maciej [1 ]
Makalowski, Marcin [1 ]
Stanisic, Michal [3 ]
Wachal, Krzysztof [3 ]
Majewski, Waclaw [3 ]
机构
[1] Poznan Univ Med Sci, Dept Radiol K Marcinkowski, Poznan, Poland
[2] Univ Warsaw, Fac Phys, Dept Biomed Phys, Warsaw, Poland
[3] Poznan Univ Med Sci, Dept Gen & Vasc Surg, Poznan, Poland
关键词
abdominal stentgraft; high dose; X-ray; radiation;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study is a case report regarding a possible problem of high radiation dose during stent-graft implantation. Before deciding on how to treat an aneurysm (stent grafting or traditional surgery), possible complications such as difficult anatomical conditions and diseases of the aorta and iliac arteries should be considered to avoid potentially high doses of radiation. In case of this patient, it was very difficult to introduce a guidewire through the contralateral limb into the body of the graft due to tortuosity and kinking of iliac arteries. Because of the long duration of the procedure (68 min), the patient was exposed to a very high radiation dose (4.37 Gy) and DAP (1760.3 Gy cm(2)).
引用
收藏
页码:60 / 62
页数:3
相关论文
共 50 条
  • [21] Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation
    Thomas Frauenfelder
    Mourad Lotfey
    Thomas Boehm
    Simon Wildermuth
    CardioVascular and Interventional Radiology, 2006, 29 : 724 - 724
  • [22] HEMODYNAMICS OF ABDOMINAL AORTIC ANEURYSM AND ITS CLINICAL RELEVANCE IN PATIENTS WITH INFRARENAL STENT-GRAFT IMPLANTATION
    Lu, Y. -H
    Liu, G. -T
    Lin, S. -H
    Chen, C. -Y
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [23] Stent-Graft Implantation to Treat an Inferior Vena Cava Aneurysm
    Falkowski, Aleksander
    Wiernicki, Lreneusz
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (05) : 714 - 717
  • [24] Separation of the Modular Stent-Graft Within the Abdominal Aortic Aneurysm
    Tsao, Nai-Wen
    Shih, Chun-Ming
    Lin, Feng-Yen
    Shao, Wen-Tein
    Lee, Chi-Ming
    Ou, Keng-Liang
    Chang, Nein-Chun
    Huang, Chun-Yao
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (12) : E199 - E199
  • [25] The choice of stent-graft for endovascular repair of abdominal aortic aneurysm
    Chuter, TAM
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04): : 519 - 525
  • [26] The use of adenosine for stent-graft deployment during endovascular abdominal aortic aneurysm repair
    Kahn, RA
    Moskowitz, DM
    ANESTHESIA AND ANALGESIA, 1999, 88 (04):
  • [27] Acute Aortic Occlusion Following Endovasculer Stent Graft Implantation in Abdominal Aortic Aneurysm: Case Report
    Bingol, Hakan
    Ozulku, Mehmet
    Gunday, Murat
    JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2014, 4 (03): : 125 - 127
  • [28] Common hepatic artery aneurysm treated with an endovascular stent-graft: a case report
    Hiroyuki Aburano
    Kyoko Morinaga
    Noriyuki Shigenari
    Dai Inoue
    Miho Okuda
    Tetsuya Minami
    Tetsuya Komatsu
    Masashi Yamashiro
    Shiro Miyayama
    Osamu Matsui
    Abdominal Imaging, 2010, 35 : 215 - 217
  • [29] Common hepatic artery aneurysm treated with an endovascular stent-graft: a case report
    Aburano, Hiroyuki
    Morinaga, Kyoko
    Shigenari, Noriyuki
    Inoue, Dai
    Okuda, Miho
    Minami, Tetsuya
    Komatsu, Tetsuya
    Yamashiro, Masashi
    Miyayama, Shiro
    Matsui, Osamu
    ABDOMINAL IMAGING, 2010, 35 (02): : 215 - 217
  • [30] The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study
    Resch, T
    Malina, M
    Lindblad, B
    Malina, J
    Brunkwall, J
    Ivancev, K
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 190 - 195