CONTROLLED EVALUATION OF BACT ALERT STANDARD ANAEROBIC AND FAN ANAEROBIC BLOOD CULTURE BOTTLES FOR THE DETECTION OF BACTEREMIA AND FUNGEMIA

被引:62
|
作者
WILSON, ML
WEINSTEIN, MP
MIRRETT, S
REIMER, LG
FELDMAN, RJ
CHUARD, CR
RELLER, LB
机构
[1] DENVER HLTH & HOSP,DEPT PATHOL & LAB SERV,DENVER,CO 80204
[2] UNIV COLORADO,SCH MED,DEPT PATHOL,DENVER,CO 80262
[3] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON MED SCH,DEPT MED,NEW BRUNSWICK,NJ 08901
[4] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON MED SCH,DEPT PATHOL,NEW BRUNSWICK,NJ 08901
[5] ROBERT WOOD JOHNSON UNIV HOSP,MICROBIOL LAB,NEW BRUNSWICK,NJ 08901
[6] DUKE UNIV,MED CTR,CLIN MICROBIOL LAB,DURHAM,NC 27710
[7] DUKE UNIV,MED CTR,DEPT PATHOL,DURHAM,NC 27710
[8] DUKE UNIV,MED CTR,DEPT MED,DURHAM,NC 27710
[9] DEPT VET AFFAIRS MED CTR,MICROBIOL LAB,SALT LAKE CITY,UT 84148
[10] UNIV UTAH,SCH MED,DEPT MED,SALT LAKE CITY,UT 84148
[11] UNIV UTAH,SCH MED,DEPT PATHOL,SALT LAKE CITY,UT 84148
关键词
D O I
10.1128/JCM.33.9.2265-2270.1995
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
FAN medium was formulated to improve microbial recovery, particularly for fastidious microorganisms and for microorganisms causing sepsis in patients receiving antimicrobial therapy, In a controlled clinical evaluation performed at four university-affiliated hospitals, FAN anaerobic bottles were compared with standard anaerobic bottles for yield, speed of detection of microbial growth, and detection of septic episodes, A total of 10,431 blood culture sets were received; both anaerobic bottles of 7,694 blood culture sets were adequately filled with blood, Altogether, 925 isolates were recovered: 557 that were the cause of sepsis, 99 that were indeterminate as the cause of sepsis, and 269 contaminants, More Staphylococcus aureus (P < 0.001), coagulase-negative staphylococci (P < 0.001), Escherichia coli (P < 0.02), and all microorganisms combined (P < 0.005) were recovered from FAN bottles; more nonfermentative gram-negative bacilli (P < 0.05), Torulopsis glabrata (P < 0.001), and other yeasts (P < 0.01) were recovered from standard bottles, Growth of S. aureus (P < 0.001), coagulase-negative staphylococci (P < 0.001), Enterococcus faecalis (P < 0.025), streptococci other than Streptococcus pneumoniae (P < 0.01), and all microorganisms combined (P < 0.001) was detected earlier in standard bottles; growth of more isolates of E. coli (P < 0.05) and anaerobic bacteria (P < 0.01) was detected earlier in FAN bottles. The mean times to detection were 14.2 and 16.1 h for standard and FAN bottles, respectively, More septic episodes caused by S. aureus (P < 0.001), coagulase-negative staphylococci (P < 0.005), members of the family Enterobacteriaceae (P < 0.02), and all microorganisms combined (P < 0.02) were detected in FAN bottles; more septic episodes caused by nonfermentative gram-negative bacilli (P < 0.025) and yeasts (P < 0.005) were detected in standard bottles, In summary, more isolates (except for strict aerobes) were recovered from FAN bottles than from standard anaerobic bottles, Similarly, significantly more septic episodes (except for those caused by strict aerobes) were detected with FAN bottles than with standard anaerobic bottles, With the exception of E. coli and anaerobic bacteria, growth of more isolates was detected earlier in standard anaerobic bottles.
引用
收藏
页码:2265 / 2270
页数:6
相关论文
共 50 条
  • [31] Growth detection of Cutibacterium acnes from orthopaedic implant-associated infections in anaerobic bottles from BACTEC and BacT/ALERT blood culture systems and comparison with conventional culture media
    Jeverica, Samo
    El Sayed, Faten
    Camernik, Petra
    Kocjancic, Bostjan
    Sluga, Bostjan
    Rottman, Martin
    Papst, Lea
    ANAEROBE, 2020, 61
  • [32] CONTROLLED EVALUATION OF THE AGAR-SLIDE AND RADIOMETRIC BLOOD CULTURE SYSTEMS FOR THE DETECTION OF BACTEREMIA AND FUNGEMIA
    WEINSTEIN, MP
    RELLER, LB
    MIRRETT, S
    STRATTON, CW
    REIMER, LG
    WANG, WLL
    JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 23 (02) : 221 - 225
  • [33] CONTROLLED EVALUATION OF 5-MILLILITERS VERSUS 10-MILLILITERS OF BLOOD CULTURED IN AEROBIC BACT/ALERT BLOOD CULTURE BOTTLES
    WEINSTEIN, MP
    MIRRETT, S
    WILSON, ML
    REIMER, LG
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (09) : 2103 - 2106
  • [34] Clinical Evaluation of BacT/Alert FA Plus and FN Plus Bottles Compared with Standard Bottles
    Lee, Dong-Hyun
    Kim, Seong Chun
    Bae, In-Gyu
    Koh, Eun-Ha
    Kim, Sunjoo
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (12) : 4150 - 4155
  • [35] Controlled Evaluation of the New BacT/Alert Virtuo Blood Culture System for Detection and Time to Detection of Bacteria and Yeasts
    Altun, Osman
    Almuhayawi, Mohammed
    Luthje, Petra
    Taha, Rubina
    Ullberg, Mans
    Ozenci, Volkan
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (04) : 1148 - 1151
  • [36] The utility of anaerobic blood culture in detecting facultative anaerobic bacteremia in children
    Shoji, Kensuke
    Komuro, Hisako
    Watanabe, Yasushi
    Miyairi, Isao
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2013, 76 (04) : 409 - 412
  • [37] Multicenter clinical comparison of resincontaining bottles with standard aerobic and Anaerobic bottles for culture of microorganisms from blood
    H. Lelièvre
    M. Gimenez
    F. Vandenesch
    A. Reinhardt
    D. Lenhardt
    H. M. Just
    M. Pau
    V. Ausina
    J. Etienne
    European Journal of Clinical Microbiology and Infectious Diseases, 1997, 16 : 669 - 674
  • [38] CONTROLLED EVALUATION OF MODIFIED RADIOMETRIC BLOOD CULTURE-MEDIUM SUPPLEMENTED WITH GELATIN FOR DETECTION OF BACTEREMIA AND FUNGEMIA
    WEINSTEIN, MP
    RELLER, LB
    MIRRETT, S
    REIMER, LG
    WANG, WLL
    STRATTON, CW
    JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (08) : 1373 - 1375
  • [39] Anaerobic bottles are still important in blood culture sets
    Khanna, P
    Collignon, P
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2001, 20 (03) : 217 - 219
  • [40] Comparison of BacT/Alert blood culture bottles with lytic media for culture of peritoneal dialysis fluid
    Wust, J
    vonGraevenitz, A
    INFECTION, 1995, 23 (06) : 378 - 379