AORTIC-VALVE REPLACEMENT WITH CRYOPRESERVED PULMONARY ALLOGRAFTS - 5 YEARS FOLLOW-UP

被引:11
|
作者
MAIR, R [1 ]
HARRINGER, W [1 ]
WIMMERGREINECKER, G [1 ]
KLIMA, U [1 ]
GROSS, C [1 ]
PESCHL, F [1 ]
BRUCKE, P [1 ]
机构
[1] GEN HOSP LINZ, DEPT CARDIOVASC & THORAC SURG, LINZ, AUSTRIA
来源
ANNALS OF THORACIC SURGERY | 1995年 / 60卷 / 02期
关键词
D O I
10.1016/0003-4975(95)00269-Q
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Excellent clinical results with pulmonary autografts and experimental evidence that pulmonary valves can withstand the higher stress in the systemic circulation led us to use the cryopreserved pulmonary allograft for aortic valve replacement. From September 1988 until March 1993, 126 consecutive patients (61 +/- 10 years; 74 men and 52 women) underwent aortic valve replacement with a cryopreserved pulmonary allograft. All allografts were inserted freehand in the subcoronary position. There were four in-hospital deaths (3.2%), and 1 patient had severe valvular incompetence immediately postoperatively, requiring reoperation after 4 weeks. One hundred twenty-one patients were followed up in 3- to 6-month intervals for 25.3 +/- 16.3 months (range, 6 to 66 months), and valve performance was assessed routinely by means of color-flow Doppler echocardiography. Nine patients (7.1%) died during follow-up. Two patients died of multiple septic emboli during bacterial endocarditis, and 1 patient died of a massive stroke. The other 6 patients died of myocardial infarction (4), respiratory insufficiency due to chronic obstructive lung disease (1), and carcinoma (1). Ninety-four patients (78%) had absent or trivial aortic valve regurgitation. Valvular incompetence class II was present in 3 patients (2.5%), whereas 5 others (4%) demonstrated class II to III. Severe aortic regurgitation (class III or IV) could be detected in 10 patients (8.3%). All underwent reoperation and replacement of the valve with a prosthetic device. Bacterial endocarditis caused graft incompetence in 3 patients, valve degeneration was detected in another 3, and technical mistakes at valve implantation caused valve failure in the other 4. We assume that a mismatch in size between the allograft and the aortic annulus could have led to dilation of the allograft valve ring and consequently to central valvular incompetence in the patients without cusp degeneration. Cryopreserved pulmonary allografts achieve acceptable intermediate-term results, which can be improved if initial technical problems can be avoided. Disturbingly, the incidence of endocarditis in our series was higher than expected.
引用
收藏
页码:S185 / S188
页数:4
相关论文
共 50 条
  • [31] REPLACEMENT OF THE ASCENDING AORTA AND AORTIC-VALVE WITH A COMPOSITE GRAFT - RESULTS AND FOLLOW-UP IN 71 PATIENTS
    DONALDSON, RM
    ROSS, DN
    THORACIC AND CARDIOVASCULAR SURGEON, 1981, 29 (04): : 195 - 199
  • [32] LONG-TERM FOLLOW-UP AFTER SEPARATE REPLACEMENT OF THE AORTIC-VALVE AND ASCENDING AORTA
    KARCK, M
    LAAS, J
    HEINEMANN, M
    BORST, HG
    HERZ, 1992, 17 (06) : 394 - 397
  • [33] AORTIC-VALVE REPLACEMENT WITH SMELOFF-CUTTER PROSTHESIS - 1 TO 8 YEAR FOLLOW-UP
    SOYER, R
    BRUNET, A
    REDONNET, M
    HUBSCHER, C
    LETAC, B
    JOURNAL OF CARDIOVASCULAR SURGERY, 1983, 24 (02): : 138 - 143
  • [34] FOLLOW-UP OF PATIENTS TREATED WITH BALLOON DILATATION OF THE AORTIC-VALVE
    TEIEN, D
    BRITISH HEART JOURNAL, 1990, 64 (01): : 107 - 107
  • [35] Follow-up study of aortic-valve replacement surgery in patients with Takayasu's disease complicated by aortic regurgitation
    Nishimura, S
    Toubaru, T
    Ootaki, E
    Sumiyoshi, T
    CIRCULATION JOURNAL, 2002, 66 (06) : 564 - 566
  • [36] AORTIC-VALVE REPLACEMENT FOR OCHRONOSIS OF AORTIC-VALVE
    LEVINE, HD
    PARISI, AF
    HOLDSWORTH, DE
    COHN, LH
    CHEST, 1978, 74 (04) : 466 - 467
  • [37] Personal follow-up of 100 aortic valve replacement patients for 1081 patient years
    Varstela, E
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1998, 87 (03) : 205 - 212
  • [38] Homograft Implantation for Aortic Valve Replacement Since 15 Years: Results and Follow-up
    Kilian, Eckehard
    Fries, Florian
    Kowert, Anke
    Vogt, Ferdinand
    Kreuzer, Eckart
    Reichart, Bruno
    HEART SURGERY FORUM, 2010, 13 (04): : E238 - E242
  • [39] 10-YEAR FOLLOW-UP IN AORTIC-VALVE REPLACEMENT USING THE BJORK-SHILEY PROSTHESIS
    CHEUNG, D
    FLEMMA, RJ
    MULLEN, DC
    LEPLEY, D
    ANDERSON, AJ
    WEIRAUCH, E
    ANNALS OF THORACIC SURGERY, 1981, 32 (02): : 138 - 145
  • [40] PULMONARY AUTOGRAFT FOR AORTIC-VALVE REPLACEMENT IN CHILDREN
    LENTINI, S
    CARTIER, P
    METRAS, J
    CLOUTIER, A
    RAYMOND, G
    DESAULNIERS, D
    DOYLE, D
    LEMIEUX, M
    ANNALES DE CHIRURGIE, 1994, 48 (08): : 749 - 754